![BEINAT LC100 Quick Start Manual Download Page 2](http://html.mh-extra.com/html/beinat/lc100/lc100_quick-start-manual_2723732002.webp)
Page 2
Power supply ................................................................................................ 3 V.cc by 2 Alkaline batteries
Battery type ...................................................................................stiyle size AAA alkaline 1.5 VDC
Battery duration ...................................................................................................... minimum 48 months
Range of contacts.......................................................................... 5A 250V. resistive - 10A 30V. resistive
Range of temperature......................................................................................... from 5 to 30 degrees C
Delta temperature.......................................................................................... From 0.2 to 0.4 degrees C
Operating Temperature .....................................................................................from -10 ° C to + 40 ° C
Operating mode .............................................................................................................. LC100 Winter
Operating mode .......................................................................................... LC150 Summer or Winter
Operating Humidity ......................................................................................... 0 to 90% RH not condensed
Body Material ........................................................................................................... ABS self extinguishing
Degree of protection ...................................................................................................................... IP30
Maximum dimensions (l*h*p) ..................................................................................................... 110x35x50
Electromagnetic Compatibility "CE ............................................................ According to Reference regulations
Positioning.The correct positioning of the thermostat is an element of absolute importance for its operation.
To get the best performance from these thermostat is necessary to follow certain principles of installation:
a) To install in the 'room of the house where it is believed there is an average temperature neither too hot
nor too cold.
b) Do not place it near sources of heat that can affect the correct
temperature reading.
c) Avoid proximity to the thermostat household appliances that give
off heat (microwave oven, refrigerators, televisions etc.).
d) Do not place in dead corners, behind doors or where there is no
circulation of air.
e) Install it to about 140 cm. from the floor.
f) Do not place the product on a wall excessively cold or warm (such
as outside walls or paths from heating pipes)
Dimensions
110 mm
5
0
mm
LC150
35 mm
5
0
mm
BOILER 4-WAY VALVE OR ZONE CONDITIONER
Technical features
Positioning and usage mode