11)  DISPLAY.  The  symbols  are  illustrated  in  the  draw.
a)  The  number  on  the  display  indicates  the  concentration  of  gas  detected.
The exchange of  data of every connected probe is every about 4 seconds.
b)  Numbers  from  1  to  4  indicate  the  monitored  probe.
c)  The  letters  ppm  means  when  the  connected  probe  detects  Toxic  gas.
The letters LEL  means when the connected probe detects Explosive gas.
d)
  The  timer  symbol  means  when  the  BX444-Mc  is  being  the  Warm  up  and  displays  the  countdown.

Description of Display

The  BX444Mc  is  equipped  with  a  display  backlight  color  to  facilitate  the  recognition  of  the  state  of  the  probe
monitored.
The  data  exchange  for  each  probe  connected  happens  every  4  seconds.

Components and Commands continue

c

000

a

ppm
LEL

1   2   3   4

d

b

00

LEL

300

ppm

The  blu  display  shows
th e  

p e rce nta g e  

of

ox y g e n. 

n orm al

condition

20.6

%

20

LEL

FAU

Th e   g re e n   d i sp l ay
shows  an  absence  of
leakage  of  gas,  normal
conditione

The  display  shows  with
red  color  a  concentration
of  explosive  gases  in
%  LEL  greater  than  a
threshold  alarm.

The  display  shows  with
red  color  a  concentration
of  toxic  gases  ppm
greater  than  a  threshold
alarm.

The  yellow  display  shows
a  fault  of  one  or  more
prob es.

The  installation of  the detector  is  not exempt from  ...… The compliance with all regulations concerning the characteristics,
installation  and  use  of  gas  appliances.  The  ventilation  of  the  spaces  and  the  elimination  of  combustion  products  are  described
in  the  UNI  norms  according  to  ART.  3  LAW  1083  /  71  and  relevant  legal  provisions.

<

19.9  %

>

21.9  %

<

19.5  %

>

22.5  %

<

18.5  %

>

23.5  %

1st Pre-Alarm

2nd Pre-Alarm

Main alarm

< Oxygen deficienty
> Excess Oxygen

The  BX444-Mc  presents  three
levels  of  danger  which  are:

Summary of Contents for BX444-Mc

Page 1: ...mall underground car parks The BX444 M control unit has three danger levels 1st LEVEL 1st Alarm This was set to 8 of L E L 120ppm 2nd LEVEL 2nd Alarm This was set at 13 of L E L 200ppm 3rd LEVEL Main Alarm This was set at 20 of L E L 300ppm For oxygen the centrol unit BX444 Mc presents three levels of danger which are 1st Pre Alarm Both in deficiency and excess of Oxygen 2nd Pre alarm Both in defi...

Page 2: ...f Conventional Sensors that can be connected 4 Micro switches to include or exclude the probes 1 per each probe Connectable probes Semi conductor Catalytic Electrochemical cell Pellistore Infrared Rays Type of faults detected by Fault Circuit Interruption short circuit or wear Input Signal 4 20 mA on 220 ohm Device Accuracy 1 FS Response Time 2 Control Unit microprocessor Functioning Temperature 1...

Page 3: ...FREON 0 300 ppm 4 20 mA 5 Yes Yes SGF108 Elettrochimica IP64 Zone 2 H2S 0 300 ppm 4 20 mA 5 Yes Yes SGF110 Electrochemical IP64 Zone 2 C O 0 300 ppm 4 20 mA 5 Yes Yes SGF112 Catalytic IP64 Zone 2 Hydrogen 0 100 LEL 4 20 mA 5 Yes Yes CO100r Electrochemical IP55 Tertiary C O 0 300 ppm 4 20 mA 5 Yes Yes CO100Ar Electrochemical IP66 Zone 2 C O 0 300 ppm 4 20 mA 5 Yes Yes SG800duct Catalytic IP66 Zone ...

Page 4: ... LED blinks when one of the connected probes is faulty if there is an interruption in the cable connection or if an error was made during wiring When this LED is blinking the device is no longer capable of detecting To reactivate the device the damaged probe must be repaired or disabled using the internal micro switch see chapter 6 paragraph A and then the RESET button must be pressed 11 EXPLOSIVE...

Page 5: ...000 a ppm LEL 1 2 3 4 d b 00LEL 300ppm The blu display shows the percentage of oxygen normal condition 20 6 20LEL FAU The green display shows an absence of leakage of gas normal conditione The display shows with red color a concentration of explosive gases in LEL greater than a threshold alarm The display shows with red color a concentration of toxic gases ppm greater than a threshold alarm The ye...

Page 6: ... connections according to Regulations in force keeping in mind that the signal cables should be laid separate from the power cables An automatic cut off switch appropriately identified as devicesectioning of the detector should be incorporated in the electrical system adequatelylocated and easily accessible Electrical Connections Diagram of the terminal block relay Power supply 110 230 VAC PH N 4 ...

Page 7: ...nnection examples Power supply 230 12V Diode 1N 5406 1 2 3 4 5 6 7 8 3 2 1 Probe 1 3 2 1 Probe 2 3 2 1 Probe 3 3 2 1 Probe 4 R1 R2 R3 R4 Solenoid valve GAS and Sirens 12 VDC 12 V If a 12Vdc solenoid valve which does not work well is connected to the BX444 Mc Direct connection of 12VDC solenoid valves or sirens to the BX444 Mc is not permitted An external power unit must always be used The BX444 Mc...

Page 8: ...On the next pass the LED probe will be maintained again and the alarm will be issued In case of fault The LED of the relevant probe starts blinking and remains lit The display will show the FAU Fault fixed indication and the buzzer will issue a continuous sound until 1 The repair has been carried out 2 The relevant probe has been disabled using the micro switch 1 2 4 3 Sensors Probe Identification...

Page 9: ...memory and the relay switches off when the connected probe no longer detects gas In compliance with the rules this function becomes active only when you select the detection of Toxic Gases reading in ppm Switch 2 4 Selecting of the control unit in oxygen detection mode By setting the micro switch to ON the device is ready to detect the oxygen The display changes color and becomes BLU ATTENTION Sel...

Page 10: ...ition of the detection sensors You can connect many types of remote sensors to this unit Therefore they should be positioned at different heights depending on the type of gas to be detected These heights are 30 cm from the lowest point of the floor in order to detect Heavy gases L P G etc 30 cm from the highest point of the ceiling in order to detect light gases Methane etc 160 cm from the lowest ...

Page 11: ...rectly connected If the Fault LED lights up Check that the connecting cables from the BX444 Mc to the probes are intact that the probes are properly powered and that the signal cable is correctly connected If the Over Load Probe LED lights up Check that the power polarity has not been inverted that no short circuit is present that the probes were not damaged during installation that no excessive c...

Page 12: ...r example sales points in case you buy a new and similar product local collection points waste collection center local recycling center etc By ensuring this product is disposed of correctly you will help prevent potential negative consequence for the environment and human health which could otherwise be caused by inappropriate waste handing of this product The recycling of materials will help to c...

Reviews: