DAM-E3311 User’s Manual V6.10
3
¾
Power Line: recommended to use more than 0.5 mm
2
(AWG20) wire
¾
Network Cable: CAT-5 series cable
¾
Conductive Film: when we use it, the module must be connected to the earth to prevent electrostatic damage
¾
Indicator: there are three indicators, one power indicator (POWER), one
Fiber connection indicator (
Link
(100BASE-FX
) and
Network indicator (100/10M (Ethernet)), the following is the specific status:
Indicator
Color
Status
Description
on
+10~+30V power supply is connected
POWER Green
off No
power
on Connect
fiber-optic
network
flashing
working
Link (100BASE-FX)
Green/Yellow
off
Fiber-optic network is not connected
on
Connected to the Ethernet
flashing
working
Green
(
Link
)
off
Ethernet is not connected
on
Connect to the 100MbpsNetwork
100/10M (Ethernet)
Yellow
(
Speed
)
off
Connect to the 10MbpsNetwork
Wiring Diagram