Beijing M&B Electronic Instruments Co., Ltd. MSA100BT Instruction Manual Download Page 27

MSA100BT

 

Peak

 

Flow

 

Meter

 

Instruction

 

Manual

 

V1.2

 

 

 

‐ 

21

 ‐

meters

 

(m)

b

.

   

Field

 

strengths

 

from

 

fixed

 

RF

 

transmitters,

 

as

 

determined

 

by

 

an

 

electromagnetic

 

site

 

survey,

a

 

should

 

be

 

less

 

than

 

the

 

compliance

 

level

 

in

 

each

 

frequency

 

range.

b

 

Interference

 

may

 

occur

 

in

 

the

 

vicinity

 

of

 

equipment

 

marked

 

with

 

the

 

following

 

symbol:

 

 

a

   

Field

 

strengths

 

from

 

fixed

 

transmitters,

 

such

 

as

 

base

 

stations

 

for

 

radio

 

(cellular/cordless)

 

telephones

 

and

 

land

 

mobile

 

radios,

 

amateur

 

radio,

 

AM

 

and

 

FM

 

radio

 

broadcast

 

and

 

TV

 

broadcast

 

cannot

 

be

 

predicted

 

theoretically

 

with

 

accuracy.

 

To

 

assess

 

the

 

electromagnetic

 

environment

 

due

 

to

 

fixed

 

RF

 

transmitters,

 

an

 

electromagnetic

 

site

 

survey

 

should

 

be

 

considered.

 

If

 

the

 

measured

 

field

 

strength

 

in

 

the

 

location

 

in

 

which

 

MSA100BT

 

peak

 

flow

 

meter

 

detector

 

is

 

used

 

exceeds

 

the

 

applicable

 

RF

 

compliance

 

level

 

above,

 

MSA100BT

 

peak

 

flow

 

meter

 

detector

 

should

 

be

 

observed

 

to

 

verify

 

normal

 

operation.

 

If

 

abnormal

 

performance

 

is

 

observed,

 

additional

 

measures

 

may

 

be

 

necessary,

 

such

 

as

 

reorienting

 

or

 

relocating

 

MSA100BT

 

peak

 

flow

 

meter

 

detector.

   

b

   

Over

 

the

 

frequency

 

range

 

150

 

kHz

 

to

 

80

 

MHz,

 

field

 

strengths

 

should

 

be

 

less

 

than

 

3

 

V/m.

 

EMC

 

Declaration

 

With

 

many

 

electronic

 

devices

 

such

 

as

 

microwave,

 

TV,

 

wireless

 

router,

 

PC’s,

 

and

 

mobiles,

 

medical

 

devices

 

in

 

use

 

may

 

be

 

susceptible

 

to

 

electromagnetic

 

interference

 

from

 

these

 

devices.

 

This

 

may

 

result

 

in

 

incorrect

 

operation

 

of

 

the

 

medical

 

device

 

and

 

create

 

a

 

potentially

 

unsafe

 

situation.

 

Medical

 

devices

 

should

 

be

 

kept

 

distance

 

1m

 

from

 

those

 

electronic

 

devices.

 

In

 

order

 

to

 

regulate

 

the

 

requirements

 

for

 

EMC

 

with

 

the

 

aim

 

to

 

prevent

 

unsafe

 

product

 

situations,

 

the

 

EN60601

1

2

 

standard

 

has

 

been

 

implemented.

 

This

 

standard

 

defines

 

the

 

levels

 

of

 

immunity

 

to

 

electromagnetic

 

interferences

 

as

 

well

 

as

 

maximum

 

levels

 

of

 

electromagnetic

 

emissions

 

for

 

medical

 

devices.

 

Medical

 

devices

 

manufactured

 

by

 

M&B

 

conform

 

to

 

this

 

EN60601

1

2

 

standard

 

for

 

both

 

immunity

 

and

 

emissions.

 

The

 

medical

 

devices

 

should

 

not

 

be

 

used

 

adjacent

 

to

 

or

 

stacked

 

with

 

other

 

equipment.

 

If

 

adjacent

 

or

 

stacked

 

use

 

is

 

unavoidable,

 

the

 

medical

 

device

 

should

 

be

 

seen

 

to

 

operate

 

normally

 

as

 

it

 

should

 

in

 

this

 

situation.

 

FCC

 

Declaration

 

Note:

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

Summary of Contents for MSA100BT

Page 1: ...ter Instruction Manual Version V 1 2 PLEASE READ ALL OF THE INFORMATION IN THE PACKAGE INSERT BEFORE USING THE PEAK FLOW METER IF YOU DO NOT UNDERSTAND THE INSTRUCTIONS CONSULT M B CALL 86 10 61253803 Working Time from Monday to Friday 8 30 17 30 OR WRITE TO market mbelec com ...

Page 2: ...MSA100BT Peak Flow Meter Instruction Manual V1 2 I Date Measurements Recommendation Signature of the physician PEF FEV1 ...

Page 3: ...ersion V1 2 Intellectual property The intellectual property of MSA100BT and its manual belong to Beijing M B Electronic Instruments Co Ltd herein below mentioned as M B Copying reproduction or translation of all or any part of the contents of this manual without M B s permission is strictly prohibited All rights reserved by M B Statement M B has the final rights to interpretation for this manual M...

Page 4: ...ort 86 10 61253803 Working Time Monday Friday 8 30 17 30 Or contact the regional service partner or distributor Order consumables and repair parts Please purchase repair parts mouthpiece etc from the M B service partner or distributor in your country Other questions Please contact us as below or visit our website www mbelec com Headquarters Company Beijing M B Electronic Instruments Co Ltd Address...

Page 5: ...e professional will tell you what action to take when there are changes in your peak flow number No matter what your peak flow measures are if you have signs and symptoms such as chest tightness shortness of breath coughing or wheezing you should follow your licensed health care professional s advice for contacting him or her Instructions for using the peak flow meter must be followed carefully in...

Page 6: ...otices 5 2 2 Transportation and Storage 6 2 3 Interference Instruction 6 2 4 Classification 6 2 5 Safe Operation and Processing Conditions 6 2 6 Standards and Regulation Compliance 7 3 MAINTENANCE 8 3 1 Battery Assemblage 8 3 2 Assemble Mouthpiece and Turbine into Main Unit 8 3 3 Cleaning 8 4 OPERATION 10 4 1 LCD Screen Display Introduction 10 4 2 First Time Use 11 4 3 Time Setting 11 4 4 Power on...

Page 7: ...tions to take when you have a change in airflow In addition you should record your peak flow measures as recommended by your physician or other licensed health care professional Reviewing peak flow measures can help you and your physician or licensed health care professional checks closely on your asthma or C O P D to provide the best treatment for you MSA100BT is suitable for children through adu...

Page 8: ...onversion turning of the leaf is converted to be pulse signal which is processed by the main controller after sampling The PEF and FEV1 value are calculated by an algorithm formula and displayed on the LCD 1 5 Step by step Instructions PLEASE READ ALL OF THE INFORMATION IN THE PACKAGE INSERT BEFORE USING THE PEAK FLOW METER IF YOU DO NOT UNDERSTAND THE INSTRUCTIONS CONSULT M B CALL 86 10 61253803 ...

Page 9: ...ree peak flow measures Write the number in your Peak Plow Diary Directions for the diary are written on the diary i How to store your peak flow meter directions will differ according to device 1 6 Technical Specification 1 Measuring method Flow Turbine sensor Volume Flow Integration 2 Measuring rang Volume 0 01L 9 99L Flow 50 L min 900L min 3 Accuracy Volume 3 or 0 05L whichever is greater Flow 10...

Page 10: ...C 55 deg C 2 Relative humidity of 93 3 Atmospheric pressure of 500hPa 1060hPa 1 10 Operating Condition 1 Environment temperature of 10 Deg C 40 Deg C 2 Relative humidity of 25 85 3 Atmospheric pressure of 860hPa 1060hPa 1 11 Device Composition MSA100BT Peak Flow Meter is divided into parts below like Figure 1 1 1 Main equipment 2 AAA 1 5 2 alkaline batteries 3 Mouthpiece and turbine sensor Figure ...

Page 11: ...tance ATTENTION Denotes potential danger or unsafe treatment which may result in slight injury or damage to the device or other property The note provides application hints or other useful information Read the note carefully to ensure safe and correct use 2 1 1 2 Explanation of Safety Symbols Symbols Explanation Denotes a note or warning content Denotes a prohibited operation The operation must ne...

Page 12: ...orage case during transportation 2 3 Interference Instruction ATTENTION The MSA100BT has functions that it does not affect normal operation of other devices or is not affected by other devices 2 4 Classification Type of protection against electric shock Internal power device Degree of protection against electric shock Type BF applied part Degree of protection against liquid penetration IP22 Protec...

Page 13: ...ATTENTION No modification of this equipment is allowed ATTENTION Do not modify this equipment without authorization of the manufacturer ATTENTION If this equipment is modified appropriate inspection and testing must be conducted to ensure continued safe use of the equipment 2 6 Standards and Regulation Compliance EN 60601 1 2006 Medical Electrical Equipment General Requirements for Safety IEC60601...

Page 14: ...NTION If do not use Meter for long time please take out batteries from battery case to avoid battery leakage ATTENTION Please select batteries with regular factory instead of fake and shoddy batteries 3 2 Assemble Mouthpiece and Turbine into Main Unit Insert mouthpiece to turbine sensor then the assemblage of mouthpiece and turbine screw clockwise into main unit See the procedure at figure 3 2 Fig...

Page 15: ...an thoroughly by swirling Thoroughly rinse the mouthpiece with water distilled water is recommended Allow the device to air dry Figure3 3 Disassemble turbine and mouthpiece ATTENTION Don t use high pressure water or running water to rinse turbine which maybe lead to damage turbine and make accuracy deteriorative Don t use boiling water to rinse turbine When dried assemble mouthpiece and turbine an...

Page 16: ...cal measurement record month T Indicate now or historical measurement record time Y Indicate now or historical measurement record year AM Indicate now or historical measurement record time is before 12 00 PM Indicate now or historical measurement record time is after 12 00 PEF Indicate now or historical measurement PEF value FEV1 Indicate now or historical measurement FEV1 value Symbol of insuffic...

Page 17: ...em default setting is year 2012 month 1 day 1 time 12 00 am o clock Assume target year is 2013 setting methods are below Figure4 2 Initial display after power on Press left key or right key to change year If press left key once the year displaying decrease 1 If press right key once the year displaying increase 1 Set 2013 you should press right key once Then press power confirm key once turn to nex...

Page 18: ...us within one minute then it will power off automatically If press any key or measure once more the system will prolong 1 minute to power off 4 5 Measuring When the system power on the last result is shown and then the device indicates READY for a measurement by two short beeps Inhale completely and hold your breath for moment Cover the mouthpiece tightly with your lips Blow into turbine as hard a...

Page 19: ...nday Friday with questions or contact with M B service partner or distributor ATTENTION If you have signs and symptoms such as chest tightness shortness of breath coughing or wheezing follow your physician s or other licensed health care professional s advice for contacting them no matter what readings you obtain If you do not get a reading contacts your physician immediately ATTENTION Do not meas...

Page 20: ...alues are normal for you You should never alter the dosages of any medication without talking to your doctor Please note that the device stores up to 300 measured values with date and time When the memory is full shown as figure4 5 erase all records yourself or visit your doctor in time let he she to analyze your data Please confirm that date and time settings are always actual Do not measure PEF ...

Page 21: ...376 411 448 487 528 572 35 286 314 344 377 411 448 487 529 572 40 284 312 342 374 409 446 485 526 570 45 278 306 336 369 403 440 479 521 564 50 270 298 328 360 395 432 471 512 556 55 258 286 316 349 383 420 459 501 544 60 243 271 301 334 368 405 444 486 529 65 225 253 283 316 351 387 427 468 511 70 204 232 263 295 330 366 406 447 490 75 180 208 238 271 305 342 381 423 466 80 153 181 211 244 278 31...

Page 22: ...t is to be as a best value 2 Press and hold Power Key for a long time while install the battery Do not loosen Power Key until you can see predicted value of PEF blinked It is traffic light scheme basic value or prediction value 3 Then use Right Key or Left Key to increase or decrease value enter your best value or normal PEF value shown as Table4 4 Press Power Key once again then display setting s...

Page 23: ...PP in the phone the APP will connect to MSA100BT automatically 2 If MSA100BT not connected to the APP the bLE symbol at the bottom flashes if MSA100BT connected to the APP the bLE symbol at the bottom always show 3 If MSA100BT connect to APP successfully MSA100BT will upload the history and current measurements to APP automatically when you finished a measurement 4 After the data transmission comp...

Page 24: ...MSA100BT Peak Flow Meter Instruction Manual V1 2 18 Figure4 8 MSA100BT enters the Bluetooth data transfer interface ATTENTION MSA100BT only supports BLE version of Bluetooth ...

Page 25: ...stem Records do not exist no records Memory is full It is better to delete records or new record is not stored battery insufficient It is better to change new batteries NO display on screen Battery is low or battery pole is reversed Change new batteries and note pole direction Measuring value error Inspect whether the leaf of turbine is run freely And the leaf is dirty Or consult whether the value...

Page 26: ...meter detector is intended for use in the electromagnetic environment specified below The customer or the user of the device should ensure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 2 kV contact 4 kV contact 6 kV contact 8 kV contact 2 kV air 4kV air 8 kV air 15 kV air 2 k...

Page 27: ...0BT peak flow meter detector b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m EMC Declaration With many electronic devices such as microwave TV wireless router PC s and mobiles medical devices in use may be susceptible to electromagnetic interference from these devices This may result in incorrect operation of the medical device and create a potentially unsafe...

Page 28: ...ing the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help...

Page 29: ...l Sensor type Turbine Measurement parameters FEV1 PEF Memory size 300 BTPS PEF and FEV1 results displayed at BTPS conditions Accuracy Meet ATS 2005 Revision accuracy requirement Volume range 0 01L 9 99L Air flow range 50 L min 900L min Volume accuracy 0 050L or 3 Air flow accuracy 10 or 20L min Resolution Volume resolution 0 01L Air flow resolution 1L min Resistance to flow Back pressure 660L min ...

Page 30: ...60hPa Zoning Green Yellow threshold 80 of reference Green Yellow threshold 50 of reference Physical specification Height 12 6 centimeter Wide 5 4 centimeter Thickness 2 8 centimeter Weight 120g contain batteries and mouthpiece Maintenance warranty Standard One year Option Provide other options The detail please contact with M B and distributors ...

Reviews: