background image

Ethernet Module 

NX5000 

Nexto Series 

 

 

Doc. Code: CE114903 

Revision: D 

Altus S. A. 

Product Description 

Nexto Series is a powerful and complete Programmable Logic Controller (PLC) with unique and innovative features. Due to its 
flexibility, smart design, enhanced diagnostics capabilities and modular architecture, Nexto PLC can be used for control 
systems in medium and high-end applications or in high speed machinery  

NX5000 redundancy link module, a  part of Nexto Series, is used in applications that require more Ethernet Interfaces than 
already available on Nexto CPUs or in applications where is necessary a high availability of automation system with uses of 
network redundancy.  

 

 

 

 

 

 

 

Its main features are: 

 

Simultaneous support to MODBUS TCP and MODBUS RTU over TCP 

 

Simultaneous operation as MODBUS master/client and server/slave 

 

Redundant architecture support (half-cluster) 

 

Network redundancy support (NIC teaming) 

 

Hot swap support 

 

Auto crossover Ethernet Interface 

 

All configuration and parameterization through MasterTool IEC XE 

 

One Touch Diag 

 

Electronic Tag on Display 

 

LCD and LED for diagnostic indication 

 

Gratuitous ARP after CPU configuration and as active interface (redundancy) 

 

Supports up to128 simultaneous connections 

 

Protection against flood attacks 

 

 

 

 

 

 

 

 

 

 

 

Ordering Information 

Included Items 

The product package contains the following items: 

 

NX5000 module 

 

Installation guide 

Product Code 

The following code should be used to purchase the product: 

 

Code 

Description  

NX5000 

Ethernet Module 

 

Summary of Contents for NX5000

Page 1: ...m with uses of network redundancy Its main features are Simultaneous support to MODBUS TCP and MODBUS RTU over TCP Simultaneous operation as MODBUS master client and server slave Redundant architectur...

Page 2: ...Nexto Series brings to PLCs is the Electronic Tag on Display This new functionality brings the process of checking the tag names of any I O pin or module used in the system directly to the CPU s graph...

Page 3: ...ge relative humidity 5 to 96 non condensing Conformal coating Yes Standards IEC 61131 2 CE 2011 65 EU RoHS 2014 35 EU LVD and 2014 30 EU EMC UL Listed UL61010 1 file E473496 DNV GL Type Approval DNVGL...

Page 4: ...ype packets in broadcast informing its IP and MAC address for all devices interconnected to the network These packets are sent during the download of a new application by the MasterTool IEC XE softwar...

Page 5: ...Ethernet Module NX5000 Nexto Series Doc Code CE114903 Revision D Altus S A 5 Physical Dimensions Dimensions in mm...

Page 6: ...Revision D Altus S A 6 Installation The following figure shows the electrical installation on the rack backplane rack All information about electrical installation mechanical assembly and module inser...

Page 7: ...all modules connections be checked and that all dust or any kind of dirt at the module s enclosure be removed at least every 6 months NX5000 offers five important features to assist the user during m...

Page 8: ...ck if the module parameters are correct 4 Off Blinking 2x Loss of master Loss of communication between module and CPU Check if the module is completely connected to the backplane rack Check if CPU is...

Page 9: ...bActiveDiagnostics TRUE Module has active diagnostics FALSE Module doesn t have active diagnostic 1 MODULE W FATAL ERROR tGeneral bFatalError TRUE Fatal error FALSE No fatal error 2 CONFIG MISMATCH tG...

Page 10: ...RD wRXErrors Receiving errors QW n 100 WORD wRXDropErrors Receiving drop errors QW n 102 WORD wRXFrameErrors Receiving frame errors Manuals For correct application MODBUS configuration and utilization...