background image

Operator Panel Drawings

6

Operator Panel Drawings

6.1 Connectors

1

2

3

4

5

6

7

8

9

Pos.

Connector

Description

1

DVI

External monitor

2

VGA

External monitor

3

COM 3/4

Communication Ports

4

COM 1/2

Communication Ports

5

LAN Port B

1 × 10/100/1000 Base-T (shielded RJ-45); Intel 82574

6

LAN Port A

1×10/100/1000 Base-T (shielded RJ-45); Intel 82559

7

USB

2 × USB Host 2.0, max output current 500 mA

8

USB

2 × USB Host 2.0, max output current 500 mA

9

Power supply

DC input range: 18-32 V DC (140 W) ATX standard

6.2 Communication Ports

Serial port, 9-pin female

Serial port, 9-pin female

Pin

COM1

COM2

COM3

COM4

1

-

RS422 Tx+

RS485 Tx+/Rx+

-

RS422 Tx+

RS485 Tx+/Rx+

2

RS232 RxD

-

RS232 RxD

-

3

RS232 TxD

-

RS232 TxD

-

4

-

RS422 Rx+

-

RS422 Rx+

5

GND

GND

GND

GND

6

-

RS422 Tx-

RS485 Tx-/Rx-

-

RS422 Tx-

RS485 Tx-/Rx-

7

RS232 RTS

-

-

RS422 RTS+

8

RS232 CTS

-

-

RS422 RTS-

9

-

RS422 Rx-

-

RS422 Rx-

Note:

RS422 Interface is not available yet.

Beijer Electronics, MAEN082D

21

Summary of Contents for iX T12C

Page 1: ...iX T12C Installation Manual English MAEN082D 2013 09...

Page 2: ...all its group companies assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only quali ed personn...

Page 3: ...ing a CompactFlash or CFast Memory Card 14 3 4 Replacing the Battery 15 4 TechnicalData 16 5 ChemicalResistance 18 5 1 MetalCasing 18 5 2 Touch Screen and Overlay 19 5 2 1 Autotex F157 207 19 5 2 2 To...

Page 4: ...ye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserves an illustrative purpose Because of the many variables associated with any particular insta...

Page 5: ...plosion Only use batteries recommended by the supplier Duringthe warrantyperiod the batteryneeds tobe replaced byan authorized Beijer Electronics service center The unit can be reset by usingthe reset...

Page 6: ...m Space requirements in millimeterswhen installingthe operatorpanel 340 mm 242 2 mm 100 mm 50 mm 50 mm 100 mm 100 mm Note The dimensions on the drawing are not proportional Caution The openings on the...

Page 7: ...llmay cause damage 2 Use the cut out dimensions thatare included on the outline drawing found in section Operator PanelDrawings and in theTechnical Data table to cut acorrectopeningin the cabinet A se...

Page 8: ...it to the power outlet Ensure that the voltage and polarity of the powersource is correct Use only shielded communication cables Separate high voltage cables from signal and supply cables 24V DC RS232...

Page 9: ...rator panelto the controller please refer to the help le for the driverin question 2 2 2 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable forthe applicati...

Page 10: ...landspare partslist are allowed 3 1 Replacing the Fan and Filter The followingis needed A newfan A Torx TX10 and a TX20 screwdriver Note Make sure to use adequate ESD protection Follow the steps below...

Page 11: ...e Replacement 4 Remove the fanby removingthe two M4x35 Torx screws 5 Reassemble with new fan and lterin reverse order Use a maximum torque of 0 4 Nm whenfastening the fanscrews Beijer Electronics MAEN...

Page 12: ...mbly it is important to take care of the cable between the front and the rear part If you disconnect a cable be sure that the right cable will be in the right position when assembling Note The exchang...

Page 13: ...5 Remove the hard disk drive from the hard drive connection onthe CPU board 6 Reassemble with the newhard disk drive inreverse order 1 2 5 SATA mass storage 2 CompactFlash slot 3 CFast slot Beijer Ele...

Page 14: ...SD protection Follow the steps belowtoreplace amemory card 1 Power off the operator panel 2 Followthe instructions in chapter Replacingthe 2 5 SATA Mass Storage to remove the front frame assembly 3 In...

Page 15: ...driver Note Make sure to use adequate ESD protection Follow the steps belowtoreplace the battery 1 Power off the operator panel 2 Followthe instructions in chapter Replacingthe FanandFilter toremove t...

Page 16: ...40 UNC Note RS422 Interface is not available yet Serial port for COM3 RS232 and COM4 RS422 RS485 9 pin D sub contact with RS232 RTS CTS chassis mounted female with standard locking screws 4 40 UNC Not...

Page 17: ...ED backlight 1280 800 pixels 16 7 million colors VGA 1 VGA resolution max 2048 1536 75Hz DVI 1 DVI D single Link Resolution max 1600 1200 or 1920 1200 with reduced blanking Active area of display W H...

Page 18: ...ollowing chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Turpentine Note If exposure to any of the above...

Page 19: ...id 50 Gumption 1 SBP 60 95 1 Ariel powderin solution 1 Hydrochloricacid 36 Sulfuric acid 10 Bleach 1 Linseed oil Tomato ketchup Castoroil Methanol Trichloroacetic acid 50 Causticsoda 40 1 Nitric acid...

Page 20: ...Autotex It is recommended to use the Auto ex EBA 180Ltouch displayprotection lm that can be ordered from Beijer Electronics Solvent Resistance Auto ex EBA 180L withstands exposure to the same chemica...

Page 21: ...B Host 2 0 maxoutputcurrent 500 mA 8 USB 2 USB Host 2 0 maxoutputcurrent 500 mA 9 Power supply DC inputrange 18 32 V DC 140 W ATX standard 6 2 Communication Ports Serial port 9 pin female Serial port...

Page 22: ...to utilize two communication ports on the same physical port the Y split cable CAB109 must be used Drawing for external cable CAB109 drawing Z7100 029E is available on the web site www beijerelectroni...

Page 23: ...Operator PanelDrawings 6 3 iX T12C Outline 224 9 9 max 8 mm 7 72 242 340 322 9 9 Beijer Electronics MAEN082D 23...

Page 24: ...Operator PanelDrawings Note A Step CAD file is available on the web site www beijerelectronics com Beijer Electronics MAEN082D 24...

Page 25: ...wire between the operator panel s quick connect plinth and the panel s chassis see 2 in drawing above 2 Connect a6 mm2 or 4 mm2 wire orgroundingbraid betweenthe operator panel s chassis and the closes...

Page 26: ...RJ45 RJ45 RJ45 Industrial Ethernet Operator panel Operator panel Operator panel Operator panel Shielded Short and unshielded 0 1 F 250 V 1 1 3 3 8 8 2 2 In some industrialunits forEthernet the RJ45 c...

Page 27: ...istobreak the shield see 3 in drawing above A more elegant methodistoexpand the shielded Ethernet cablingwith a piece of unshielded Ethernetcable see 4 in drawingabove The shield canbe grounded via an...

Page 28: ...s to connect the otherend of the shield to the ground via a 0 1 F 250 V plastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms o...

Page 29: ...to heat The lifespan of an electrolytic capacitoris cut in halfwith an 8 10 C increase in temperature A 15 20 C temperature increase resultsin a quarter of the lifespanetc Rittal has a goodprogram for...

Page 30: ...Vaccording to EN 60950 protection against electric shock andUL 950 Example Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay co...

Page 31: ...hield mustbe grounded at one end The other end is usuallygrounded but with longerdistances or whenthere is adifference in the ground potential the shield should be connected tothe ground via 0 1 F 250...

Page 32: ...ces like for example serial devices 1 Connect aUSBKeyboard 2 Connect power supply and turn onthe operator panel 3 While booting press the F2 key immediately afterthe keyboard isinitialized The initial...

Page 33: ...lationTips 7 9 Reset Switch A resetswitch is locatedunder the fan lid Follow the instructionsin chapterReplacing the Fanand Filter on how toremove the fan lid to accessthe reset switch Beijer Electron...

Page 34: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...