Controls

FILTAMP MODULE 1006 Controls

(1) 

FILTER 

– Adjusts the cutoff frequency for the filter.

(2) 

FILTER RESONANCE

 – Boosts the resonance frequencies selected 

with the Filter knob, potentially causing VCF oscillation. 

(3) 

AMPLIFIER GAIN

 – Controls the level of the VCA. 

(4) 

KEYBOARD knob

 – Attenuate the voltage connected to the KYBD 

input, which controls the cutoff frequency of the filter. 

(5) 

IN B knob

 – Adjusts the level of the signal connected to the  

IN B input. 

(6) 

CV 2 to VCF knob

 – Attenuate the voltage that is passed from the 

CV 2 input to the VCF. 

(7) 

IN A knob

 – Adjusts the level of the signal connected to the  

IN A input.

(8) 

CV 1 to VCF knob

 – Attenuate the voltage that is passed from the 

CV 1 input to the VCF.

(9) 

EXPONENTIAL/LINEAR switch

 – Select between a linear or more 

natural exponential VCA response. 

(10) 

CV 2 to VCA knob

 – Attenuate the voltage that is passed from the 

CV 2 input to the VCA.

(11) 

CV 1 to VCA knob

 – Attenuate the voltage that is passed from the 

CV 1 input to the VCA.

(12) 

IN A

 – Connect an input signal via 3.5 mm TS cable. 

(13) 

IN B

 – Connect an input signal via 3.5 mm TS cable.

(14) 

KYBD

 – Connect a voltage that can be used to control the VCF 

frequency. 

(15) 

CV 1

 – Connect a voltage that can be used to control the VCF 

frequency or VCA level. 

(16) 

CV 2

 – Connect a voltage that can be used to control the VCF 

frequency or VCA level.

(17) 

OUT

 – Send the processed signal to other modules via 3.5 mm  

TS cable.

(4)

(9)

(1)

(2)

(3)

(12) (13) (14) (15) (16) (17)

(10)

(11)

(5)

(7)

(6)

(8)

4

5

Quick Start Guide

FILTAMP MODULE 1006

Summary of Contents for FILTAMP MODULE 1006

Page 1: ...Quick Start Guide FILTAMP MODULE 1006 Legendary 2500 Series 24 dB Low Pass VCF and VCA Module for Eurorack V 1 0...

Page 2: ...ica es sem aviso pr vio Todas as marcas s o propriedade de seus respectivos donos Midas KlarkTeknik Lab Gruppen Lake Tannoy Turbosound TC Electronic TC Helicon Behringer Bugera Aston Microphones e Coo...

Page 3: ...CF knob Attenuate the voltage that is passed from the CV 1 input to the VCF 9 EXPONENTIAL LINEAR switch Select between a linear or more natural exponential VCA response 10 CV 2 to VCA knob Attenuate t...

Page 4: ...tet wird 9 EXPONENTIAL LINEAR switch W hlen Sie zwischen einer linearen oder einer nat rlicheren exponentiellen VCA Reaktion 10 CV 2 to VCA knob D mpft die Spannung die vom CV 2 Eingang zum VCA geleit...

Page 5: ...a resposta VCA exponencial linear ou mais natural 10 CV 2 to VCA knob Atenua a tens o que passa da entrada CV 2 para o VCA 11 CV 1 to VCA knob Atenua a tens o que passada da entrada CV 1 para o VCA 12...

Page 6: ...n 17 OUT Skicka den bearbetade signalen till andra moduler via 3 5 mm TS kabel 1 FILTER Reguluje cz stotliwo odci cia filtra 2 FILTERRESONANCE Wzmacniacz stotliwo ci rezonansowe wybrane pokr t em Filt...

Page 7: ...nidad viene con el cable de alimentaci n necesario para conectarse a un sistema de alimentaci n est ndar Eurorack Siga estos pasos para conectar la alimentaci n al m dulo Es m s f cil realizar estas c...

Page 8: ...finale tablie serrez les vis vers le bas Netzanschluss Das Ger t wird mit dem erforderlichen Netzkabel zum Anschluss an ein Standard Eurorack Stromversorgungssystem geliefert Befolgen Sie diese Schrit...

Page 9: ...final aperte os parafusos Power Connection L unit viene fornita con il cavo di alimentazione necessario per il collegamento a un sistema di alimentazione Eurorack standard Seguire questi passaggi per...

Page 10: ...et schroefdraad Bevestig de schroeven halverwege om te beginnen waardoor kleine aanpassingen aan de positionering mogelijk zijn terwijl u ze allemaal op n lijn krijgt Nadat de definitieve positie is b...

Page 11: ...u ca ej obudowy Swobodnie poruszaj ce si gwintowane p ytki umo liwiaj precyzyjne ustawienie modu u ale ka da p yta powinna by ustawiona w przybli eniu w stosunku do otwor w monta owych w module przed...

Page 12: ...of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that t...

Page 13: ...We Hear You...

Reviews: