background image

F-20404-4 

TECHNICAL INFORMATION 70118

 

Rev. 1-10-19  10-3-05

Extreme Weather Poly Electric Drinker

Model AHW100 (54150158)

CUSTOMER SERVICE CENTER

PO Box 569

Columbus, NE

68602-0569

Ph: 800-447-2751

Fax: (402) 563-7447

www.behlencountry.com

Hardware Kit

54900078

THANK YOU FOR PURCHASING THIS PRODUCT

Behlen Country has been in the business of providing quality products for more than 80 years.  

Our products will provide many years of service when maintained by the owner and used in 

accordance with the capabilities of the product.  For questions about this product, 

or for parts inquiries, please contact our Customer Service Center listed below.

Before beginning, please read the 

instructions thoroughly to make sure you 

have all of the necessary components for 

your installation.

Location of the Drinker

If you are installing your drinker in a new 

location some things can be done to enhance 

the performance of your drinker and lower your 

operating costs.  If the drinker can be located in 

a sheltered area, especially shielded from the 

north wind, then the heater will need to operate 

less and livestock will be more likely to drink 

more.
However, we realize that it is not always 

possible to locate the drinker in a sheltered 

area, but even if the drinker is exposed and out 

in the open, it would still be advantageous by 

locating the drinker with the access door to the 

south.  

Water Supply Line

When installing your drinker please comply 

with all local plumbing codes.  The horizontal 

underground water supply line should be ¾” 

with a ¾” supply riser pipe.  A ¾” I.D. pressure 

hose is supplied with your drinker.  We suggest 

connecting the 

fl

 ex hose with 3/4” NPT x 3/4” 

hose barb connectors and hose clamps (these 

can be purchased locally) to the riser pipe. 
If desired, a shut-off valve can be installed 

under the drinker to allow for easier servicing.  

NOTE: 

 If the heat is going to be shut off during 

the winter, a means must be provided to drain 

the supply line down below the frost line to 

prevent freezing of the riser pipe.  

Tip:

  Behlen 

Country has a Shut-Off Valve Kit (54130168) 

that can be used to shut off the water supply 

and drain the riser pipe.

Before hooking up your drinker, the supply 

line 

MUST BE

 

fl

 ushed to ensure that no 

contaminates will foul the valve upon start up of 

your drinker.  

NOTE:

 Your drinker is equipped 

with an MC valve that is easy to clean and 

adjust. If low water pressure conditions exist 

and a higher 

fl

 ow rate is desired, a larger inlet is 

available (3888247).

Preparing the Mounting Platform

Install the drinker on a 4” (minimum) thick 

concrete base, slightly raised above the ground 

level for better drainage. (Note: The pad should 

be a minimum of 4” larger than the drinker.)  

For the AHW100 Drinker, a 24” x 34” minimum 

pad is required.  If you are replacing a drinker 

and going to use an existing platform made 

for a different drinker, it must have a 24” x 34” 

fl

 at mounting area.  If it doesn’t have a large 

enough area, you can pour a cap over the 

existing platform to enlarge it or replace the 

platform.
Extending the platform provides animals with 

a secure place to stand while drinking.  If you 

extend the platform beyond the minimum it is 

advisable to slope the platform outside of the 

mounting area to promote better drainage.  

A smooth surface is recommended for the 

mounting area of the drinker and rough surface 

on the area where the animals will stand to 

drink.  If you are pouring a new platform you 

have the option of using anchor bolts set into 

the concrete when wet or drilling and using 

expandable anchor bolts after the concrete 

has cured to mount your drinker.  Refer to 

illustration # 1 for detailed measurements of the 

hole pattern.

Summary of Contents for AHW100

Page 1: ...to the riser pipe If desired a shut off valve can be installed under the drinker to allow for easier servicing NOTE If the heat is going to be shut off during the winter a means must be provided to drain the supply line down below the frost line to prevent freezing of the riser pipe Tip Behlen Country has a Shut Off Valve Kit 54130168 that can be used to shut off the water supply and drain the ris...

Page 2: ...or details Make sure the tile or earth tube extends below the frost line for your area The tile or earth tube must be left open to give access to warmer air from below the frost line thus preventing the riser from freezing If the soil in your area does not drain well it is recommend that a gravel bed be used under the earth tube to promote drainage if water happens to get in the earth tube The top...

Page 3: ...d using four 3 8 x 4 expandable anchor bolts with 3 8 fender washer purchased locally While the basin is off it is good time to install the hose barb connection to the riser pipe Reinstall the basin assembly to the base and remove the side access door You can leave the float cover off until the water level is adjusted Electrical Connections NOTE Electrical connections should be made by a qualified...

Page 4: ...r one of the two black wires of the thermostat Third Connection The other black wire from the thermostat connects to the black hot wire of the supply line Refer to the illustration below for details and schematic of this wiring connection Do NOT turn on the power until after the water connections have been made and tested to assure that there are no leaks NOTE The use of the riser pipe as the grou...

Page 5: ...nd of the drain spout from the outside of the drinker See Illustrations 8 9 The water can now be turned on and the float level set Adjust the float by using the two thumb screws Set the float to maintain a water level in the trough of 1 to 1 below the top of the rim of the trough See illustration 10 Check all connections for leaks and if none are present the power can be turned on to the unit and ...

Page 6: ... the Rubber Seal in the Plunger and opening to the Valve of any mineral deposits or dirt buildup that may be obstructing the normal operation of the Valve Rubber Seal is inserted inside Plunger Rubber Seal Plunger Upper Arm Plunger w seal Cover Pins STEP 1 Slide off Cover pivot Upper Arm up and remove the Plunger Upper Arm Lower Arm Pins STEP 4 Replace the Plunger with the nipple facing out and th...

Page 7: ... to the valve be sure to attach the arm to the correct side of the valve The grooves on the valve and float arm must match Please note that the valve has coarse grooves on one side and fine grooves on the other The fine grooved side is used with the float arm see below for details To adjust the water level in the drinker loosen the thumb screws and position the float and arm so that the valve is t...

Page 8: ...enetrations Make sure the fountain is sealed from wind between the concrete platform and bottom of the drinker Make sure there are no leaks around the access door Make sure that the latches are holding the float cover securely to drinker If the latches are loose adjust spring tension on the latch and if necessary bend the latch ends in vise thus enabling the latches to hold the cover tighter Valve...

Reviews: