Please consider your environment when you dispose of your
one-way batteries or accumulators. They belong in a rubbish
dump for hazardous waste. In most cases, the batteries can
be returned to their point of sale.
Please, comply with the respective valid regulation regarding the re-
turn, recycling and disposal of used batteries and accumulators.
If an instrument is not used over an extended time period, the ac-
cumulators or batteries must be removed. Should the instrument be
contaminated by leaking battery cells, the instrument has to be re-
turned for cleaning and inspection to the factory.
6.2 Calibration Interval
The instrument has to be periodically calibrated by our service depart-
ment in order to ensure the specified accuracy of measurement results.
We recommend a calibration interval of one year.
7.0 Technical Data
(for 23°C ± 5%, less than 80% rel. humidity)
Display:....................................3
1/
2
digit, numerical LCD, max. display
3200 digits with symbols for units and di-
scharged battery
Battery display: ........................"
" in display screen requires battery
replacement
Overflow display: ....................all digits are flashing
Sampling rate: ........................2 measurement / s
Max. clamp diameter: ..............33 mm (closed current converter) 20 mm
(open current converter)
Operation temperature:............0°C...+40°C, for less than
80% rel. humidity
Storage temperature: ..............-10°C...+60°C, for less than
70% rel. humidity
Auto Power Off: ......................approx. 10 min
Height above sea level: ............up to 2000m
Degree of contamination: ........2
Overvoltage class: ..................CATII / 600V, CATIII / 300V
towards ground
+
-