Specifications
(at 23 °C ± 5 °C, max. 75% rel. humidity)
Display: 3
3
/4
, LCD incl. functions and symbols
Bargraph:
40 segments
Range selection:
manual
Auto power-off:
approx. 15 min.
Overload display:
Measuring rate:
30 measurements/sec. (Bargraph)
3 measurements/sec. (LCD)
Clamp opening:
ca. 30 mm
Overvoltage category:
CAT II, 600 V
Pollution degree:
2
Height above MSL.:
up to 2000 m
Battery display:
at low battery
Power supply:
2 x 1,5 V IEC LR6 (alkaline) batteries
Current consumption:
approx. 10 mA
Operation temperature:
-10 °C … 50 °C (14 °F … 122 °F)
Storage temperature:
-20 °C … 60 °C (-4 °F … 140 °F)
Humidity:
< 75% relative humidity
Dimension:
183 x 63.6 x 35.6 mm (7.2 x 2.5 x 1.4 in)
Weight:
0.44 lb (7 oz)
Current AC
Range
Resolution Accuracy
50 Hz/60 Hz
40 Hz … 1 kHz
0 – 40 mA
0 – 400 mA
0 – 4 A
0 – 40 A
10 µA
100 µA
1 mA
10 mA
±(1,5 % rdg. +3 D)
±(2,0 % rdg. +5 D)
0 – 50 A
0,1 A
±(1,5 % rdg. +5 D)
±(2,0 % rdg. +5 D)
50 – 60 A
0,1 A
±(3,0 % rdg. +5 D)
±(3,5 % rdg. +5 D)
Voltage AC
Range
Resolution Accuracy
50 Hz/60 Hz
40 Hz … 1 kHz
0...400 V
0,1
Ω
±(1,0 % rdg. +3 D)
±(2,0 % rdg.± 4 D)
Resistance
Range
Resolution
Accuracy
Overload Protection
400
Ω
0,1
Ω
±(1 % rdg. +3 D)
600 V AC
Continuity
Range
Resolution
Beep
Open Circuit Voltage
Ω
/
R
0,1
Ω
ON
≤
10
Ω
; OFF > 38
Ω
< 0,4 V
Overload Protection 600 V AC
12
www.
GlobalTestSupply
.com
Find Quality Products Online at: