BEGLEC Magic Gobo User Manual Download Page 4

 

4C

 A. 

 GENERAL INSTRUCTIONS  

    The following points are important for safety as well as for the smooth 

installation and performance of the unit. 

 

• Unpack carefully and be sure that no damage has occurred during shipping. 

• It is very important to ground the yellow/green conductor in order to meet 

regulations for safety. 

• Do not connect the device to any dimmer pack

 

or power pack.

 

• The electrical work that is necessary for installation must do by qualified   

personnel. 

• Be sure to locate the unit in a place with adequate ventilation at least 15 cm from 

the walls. Be sure that no ventilation slots are blocked. 

• Be careful that no liquids or other objects can enter the unit. If this ever happens, 

disconnect the main power immediately.   

• In the event of serious operating problems, turn off the unit immediately. Never try 

to repair the unit yourself. Repairs carried out by non-qualified personnel can lead 

to serious damage or malfunction. Please contact your dealer about authorized 

technical assistance. Always use genuine spare parts. 

 

Occasional breaks are necessary to prevent breakdowns. This unit is not designed 

to be used non-stop. 

• Always remember to unplug the unit from the mains power before any service is 

done. 

• Please recycle the packaging.

 

 

 

 

 

 

 

 

• Start the address 

1. Select the channels of DMX controller 

2. Dip switches   

Dip #1 #2 #3 #4 #5 #6 #7 #8 #9 

Value 

1 2 4 8 16 32 64 

128 

256 

• Examples:   

Channel 1 : dip / on : #1 (=1) 

Channel 4 : dip / on : #3 (=4) 

Channel 7 : dip / on : #1, #2, #3 (1+2+3=7) 

Channel 10 : dip / on : #2, #4 (2+8=10) 

 

(2). Preprogram functions 

•The unit can be linked together as master/slave in 2 or 4 channels and run by built 

in preprogrammed chase sequences by sound activation. When sound stops, all 

the lights will shut down (blackout) immediately and then the bulb will turn off 15 

seconds later. Please refer to the unit dipswitch-setting table for how to set the 

dipswitches to achieve master/slave linking. 

•In master/slave mode, the dipswitch 10 must be on of the master unit. 

 

2-Channels dip switches setting 

Master 

Slave 1 

4-Channels dip switches setting 

Master 

 

Slave 1 

 

Slave 2 

 

Slave 3 

 

Summary of Contents for Magic Gobo

Page 1: ...BEGLEC Sound Light WWW JBSYSTEMS BE WWW BEGLEC COM User Guide Please read these instructions carefully before use ...

Page 2: ...rdance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 3: ...the led light on it is in SLOW mode the unit movement slowly E FIXTURE CLEANING The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with a ...

Page 4: ...ion Please contact your dealer about authorized technical assistance Always use genuine spare parts Occasional breaks are necessary to prevent breakdowns This unit is not designed to be used non stop Always remember to unplug the unit from the mains power before any service is done Please recycle the packaging Start the address 1 Select the channels of DMX controller 2 Dip switches Dip 1 2 3 4 5 6...

Page 5: ...ull DMX512 control One gobo color wheel with15 gobos plus shutter and 12 one color 1 two colors and 1 four colors plus white accurate focusable optics system and stepper motor with blackout feature Fan cooled When the light receives blackout signal of DMX512 the bulb will shut down blackout immediately and then the bulb will turn off 15 seconds later It can be operated by DMX512 control or can be ...

Page 6: ...dvisable to connect a DMX terminal 2 DMX 1 COMMON DMX 3 1 2 1 3 2 DMX OUTPUT DMX INPUT A DMX512 system requires a controller lighting equipment and cable These are connected together in a daisy chain with the terminator at the end The cable cannot be branched or split to a Y cable The terminator requires a 90 120 Ohm 1 4 Watt resistor soldered between two signal cables The DMX512 uses a very high ...

Reviews: