12  Maintenance 

12.1  Service instructions 

In order to guarantee flawless functioning of the device and thus optimal presentation of the 
goods, the entire technology must be regularly checked and maintained. 

12.2  Normal maintenance 

The normal and preventative maintenance essentially consists of a weekly cleaning of all 
stainless  steel  parts,  which  have  to  be  cleaned  with  lukewarm  water  and  soap,  then  
thoroughly rinsed and carefully rubbed dry. Before doing this, however, the device must be 
disconnected from the power supply. 

12.3  Extraordinary maintenance 

Extraordinary  maintenance  is  carried  out  by  specialist  personnel  in  case  of  damage  or  
malfunctions, wherever possible disconnect the device from the power supply beforehand. 

Both  repairs  and/or  exchange  of  components  could  prove  to  be  necessary.  All  defective 
parts have to be exchanged exclusively with equivalent materials and components or those 
recommended by the manufacturer. 

 
 
 
 
 
 
 
 

 
 

12.4  Replacing the glasses 

The side panels must always be pushed in all the way to the support so that they do not 
come to rest on the stopping bar of the front panel holder. If they are resting on the stopping 
bar, the upper glass holder will be lifted too far so that the front glass panel can fall out if 
touched. 

The panels can be partly or completely lifted out of their holders for cleaning. 

Please insert the glasses exactly the way it is indicated on the drawings below: 
 
 

Figure 1 

Pull the sneeze screen forward 

(1)

 

 

Fit the front glass panel and turn it to the inside 

(2)

 

Push sneeze screen back into place 

(3)

 

 

If  the  user  exchanges  components  or makes  changes  to the  device  without 
written authorisation from the manufacturer, or uses non-authorised replace-
ment parts, the warranty is immediately void. 

i

 

Summary of Contents for Uno Top Cold

Page 1: ...Uno Top Cold The world s most compact refrigerated showcase system Operation Manual Installation Technical Specifications...

Page 2: ...4 4 Glazing Danger of accident 8 5 Warranty and liabilities 9 6 Transport of Uno Top Cold 10 7 Packaging of Uno Top Cold 10 8 Installation of Uno Top Cold 11 8 1 Setting up and moving the device 11 8...

Page 3: ...efully read these installation and operating instructions before installing the appliance and putting it into service and strictly follow the notices herein thus contributing to keeping the appli ance...

Page 4: ...enance Therefore the operations manager and the operators must read the entire manual before the unit is installed and put into operation The manual must always be kept close to the unit and easily ac...

Page 5: ...s of the appliance or the use of individual spare parts and especially parts essential for the functioning of the appliance that are not original Beer Grill parts as well as non adherence to notes in...

Page 6: ...count may the safety installations be altered Warning signals placed directly on the device must be strictly observed at all times The device must be checked and serviced regularly at least once per y...

Page 7: ...technology electrical installation and mechanical work Any alteration must be authorized by the manufacturer in order to maintain warranty Those covers bearing a warning may only be opened by speciali...

Page 8: ...nvironment counter and floor Replace broken items Refit shatter protection glass with bracket Refill counter Counter is ready for reopening 4 4 Glazing Danger of accident Beer counters are equipped wi...

Page 9: ...operating and servicing of the unit Operating the unit with defective safety devices or safety devices which have not been installed properly and are not in working condition Disregard of the referen...

Page 10: ...g complaint period For transport please note the following points When transporting ensure that the pallet is secured against slippage and tipping Always transport the packaged device upright and do n...

Page 11: ...re The appliances are equipped with electronic controls and ventilation Please take care that no equipment with substantial emanations of heat grease or steam griddles deep fryers bain maries etc are...

Page 12: ...in creases operating costs 8 2 Preparation at the installation site Ensure that furniture cladding and counters are prepared according to the technical specifications Compare the operating voltage on...

Page 13: ...socket must be accessible after mounting or installation of the equipment Replacement of the cable must be carried out only by the manufacturer service techni cian or authorized dealer 10 Start up Ope...

Page 14: ...e documented in detail in the operating manual The following principles apply As an optimum the products in Uno Top Cold can maintain the temperatures at which they were put into the counter Repeatedl...

Page 15: ...igeration unit is switched on and off by the green toggle switch The digital temperature display of the cooling areas is located above the switches The screen displays the average temperature and the...

Page 16: ...pending on the surrounding temperature and humidity the interior temperature is not to be set too low as this could lead to icing on exposed areas of the cooling element This will interfere with the c...

Page 17: ...sing the UP key you can easily switch from AP0 to AP6 and thus select the simplified parameter list ring list Step 4 Select sensor type o06 The display automatically shows sensor parameter selection o...

Page 18: ...DOWN keys to show the parameter list To select a pre installed application configure the parameter o61 Press SET to gain access to the parameter o61 Use the UP DOWN keys to select an application AP0...

Page 19: ...ess DEFROST for 3 seconds to stop manual defrosting The DEFROST symbol is displayed during defrosting Displaying an active alarm Press QUICK COOLING for 3 seconds to start quick cooling Pud stands for...

Page 20: ...abrasive sponges must not be used as these can damage the metal surfaces or covers The unit has to be cleaned daily Wear acid proof gloves while cleaning the parts to prevent skin irritations After cl...

Page 21: ...le detergents Never use sharp edged or metallic tools like steel wool or scrubbing cleanser for cleaning The floor under the device must not be cleaned with corrosive cleaning agents since vapours cou...

Page 22: ...ons wherever possible disconnect the device from the power supply beforehand Both repairs and or exchange of components could prove to be necessary All defective parts have to be exchanged exclusively...

Page 23: ...r to the Front if touched 12 5 In case of malfunctions Before requesting service please check the mains connection and the fuses and check the following points If the cooling unit does not work at all...

Page 24: ...the error please contact customer service 13 Disposal At the end of its service life the device must be disconnected form the power supply before dismantling the individual components Here it must be...

Page 25: ...ger function properly In this case the appliance must be repaired by a qualified technician or by the Beer Grill customer service When contacting after sales service always indicate serial number and...

Page 26: ...00 K rnerstrasse 14 a Tel 49 0 71 61 659 876 info beergrill com CH 5612 Villmergen Fax 41 0 56 618 7849 D 79539 L rrach Fax 49 0 71 61 659 879 www beergrill com Seite 26 15 Appendix Drawing No 63Ma081...

Page 27: ...Subject to change without notice 63Ma081 00 UNO Top Cold GN 1 1 100 Ausf hrung gerade Ex cution plane Straight version 06 10 2017 M B sch 1 7 1 1 Format A3 359 315 30 10 6 657 Bedienerseite C t op ra...