11
GAS SPECIFICATIONS
GAS SPECIFICATIONS
GAS TYPE
UNIVERSAL LPG
NATURAL GAS
Maximum gas
consumption
20 MJ/h
20 MJ/h
Injector office
diameter
0.9 mm AU/NZ
0.95mm (North
America)”
1.83 mm
Number of injectors 2
2
Regulator pressure 2.75 kPa
1.00 kPa
NOTES:
• This appliance MUST be serviced only by a qualified
licensed person.
• This product is intended for outdoor use only.
• This product must be installed as per the instructions.
• Ventilation holes in the unit must not be obscured by the
installation.
Gas bottle safety information
• This appliance is designed to be used with a gas cylinder
not exceeding 9kg capacity.
• The gas cylinder must be made and marked in
accordance with specifications for LPG cylinders.
• The isolation valve must be turned off when the
appliance is not in use.
• Gas cylinders must be stored in an approved housing out
of reach of children.
• When disconnecting the gas bottle ensure that all the
control valves are in the ‘OFF’ position.
• Remove gas cylinder from the cylinder hook before
disconnection.
• When reconnecting the hose to the bottle, ensure that all
connections are tight before replacing the bottle onto the
gas cylinder hook.
• Carry out a leakage check as detailed below after each
reconnection.
In North America, the installation must conform with local
codes or, in the absence of local codes, with either the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas
and Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2.
Gas bottle installation
• Connect the gas hose to the gas bottle.
• Place the gas bottle onto the cylinder hook at the rear
of the barbecue.
Leak test procedure (Universal LPG)
• Ensure all gas valves are in the ‘OFF’ position.
• In a small container, mix a solution of water and
detergent or soap.
• After connection of the hose, turn on the valve at the gas
bottle or mains as appropriate.
• Using a brush apply the solution to the gas connection
points and look for bubbles forming.
• Bubbling will indicate a leak.
• Turn off the valve and re-tighten the joint. Repeat the
leak test.
• If the leak persists, turn off the gas at the isolation
valves and contact a licensed gas fitter to correct.