1. GENERAL INFORMATION

Before using the product carefully read the information 

contained in this instruction manual, the manual should 

be kept for future reference.

Italian is the original language of this instruction

manual, this language is the reference language in 

case of discrepancies in the translations.

This manual is part of the essential safety requirement

and  must  be  retained  until  the  product  is  finally  de-

commissioned.

The customer, in case of loss, can request a copy

of the manual by contacting 

Bedu Pompen BV

 or their 

agent, specifying the type of product data shown on 

the label of the machine (see 2.3 Marking)

Any changes, alterations or modifications made to the

product or part of it, not authorized by the manufacturer, 

will revoke the “CE declaration” and warranty.

This appliance should not be operated 

by children younger than 8 years, 

people with reduced physical, sensory 

or mental capacities, or inexperienced 

people who are not familiar with the 

product, unless they are given close 

supervision or instructions on how to 

use it safely and are made aware by a 

responsible person of the dangers its 

use might entail.

Children must not play with the 

appliance.

It is the user's responsibility to clean 

and maintain the appliance. Children 

should never clean or maintain it 

unless they are given supervision.

Do not use in ponds, tanks or 

swimming pools or where people may 

enter or come into contact with the 

water.

Read carefully the installation 

section which sets forth:

 

The maximum  permissible

structural  working pressure

(chapter 3.1).

-  

The type and section of the

power cable (chapter 6.5).

-  The type of electrical protection

to be installed (chapter 6.5).

1.1. Symbols

To improve the understanding of the manual, below are 

indicated the symbols used with the related meaning.

 

 

Information and warnings that must be 

observed, otherwise there is a risk that the 

machine could damage or compromise 

personnel safety.

The failure to observe electrical information 

and warnings, could damage the machine or 

compromise personnel safety.

i

  Notes and warnings for the correct management 

of the machine and its parts.

   Operations that could be performed by the final 

user. After carefully reading of the instructions, 

is responsible for maintenance under normal 

conditions. They are authorized to affect 

standard maintenance operations.

Operations that must be performed by a 

qualified  electrician.  Specialized  technician 

authorised to affect all electrical operations 

including maintenance. They are able to 

operate with in the presence of high voltages.

  Operations that must be done performed by 

a  qualified  technician.  Specialized  technician 

able to install the device, under normal 

conditions, working during “maintenance”, 

and allowed to do electrical and mechanical 

interventions for maintenance. They must 

be capable of executing simple electrical 

and mechanical operations related to the 

maintenance of the device.

 Indicates that it is mandatory to use individual 

protection devices.

OFF

  Operations that must be done with the device 

switched off and disconnected from the power 

supply.

ON

  Operations that must be done with the device 

switched on.

SUMMARY

1.

GENERAL INFORMATION 

2.

TECHNICAL DESCRIPTION 

3.

TECHNICAL FEATURES 

4.

SAFETY 

5.  TRANSPORTATION AND HANDLING 

6.

INSTALLATION 

7.

STARTUP AND OPERATION 

8.

MAINTENANCE 

9.

DISPOSAL 

10. SPARE PARTS 

11. ESIGNATION OF PARTS 

12. TROUBLESHOOTING 

Drawing for dismantling and assembly 

Declaration of conformity 

CT,T, TP,  Rev24.indd   8

15/01/18   15:46

www.bedu.nl 

Summary of Contents for CT

Page 1: ...OPERATING INSTRUCTIONS Close coupled peripheral pumps CT T TP ...

Page 2: ...CT T TP Rev24 indd 1 15 01 18 15 46 www bedu nl ...

Page 3: ... cable chapter 6 5 The type of electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with the related meaning Information and warnings that must be observed otherwise there is a risk that the machine could damage or compromise personnel safety The failure to observe electrical information and warnings could dam...

Page 4: ...or the purpose described in paragraph 2 1 Improper use of the device is forbidden as is use under conditions other than those indicated in these instructions Improper use of the product reduces the safety and the efficiency of the device Bedu shall not be responsible for failure or accident due to improper use 2 3 Marking The following picture is a copy of the name plate that is on the external ca...

Page 5: ...ements and installation site dimensions The customer has to prepare the installation site in order to guarantee the right installation and in order to fulfill the device requirements electrical supply etc The place where the device will be installed must fulfill the requirements in the paragraph 3 2 It s Absolutely forbidden to install the machine in an environment with potentially explosive atmos...

Page 6: ...p is located above the water level suction lift operation or with a positive suction head which is too low less than 1 m to open the non return valve fill the pump through the priming hole When the liquid level on the suction side is above the pump inflow under positive suction head fill the pump by opening the suction gate valve slowly and completely keeping the delivery gate valve open to releas...

Page 7: ...g For dismantling and re assembly see construction in the cross section drawing To remove the impeller 28 00 T TP use the threaded dismantling holes 9 DISPOSAL OFF The final disposal of the device must be done by specialized company Make sure the specialized company follows the classification of the material parts for the separation Observe the local regulations and dispose the device accordingly ...

Page 8: ...See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passages of the rotor 4c Rotor deteriorated 4d Worn rotor and pump case 4e Excessive viscosity of the liquid pumped if other than water 4f Incorrect direction of rotation 4g Suction head excessive in relation to the suction ca...

Page 9: ...2 12 20 81 00 82 04 94 02 76 04 94 00 76 54 98 00 98 08 14 00 98 04 70 00 14 04 82 00 90 00 88 00 3 94 112 28 20 28 00 12 00 14 20 3 94 114 14 00 14 24 12 24 32 00 14 12 3 94 113 14 00 32 00 14 24 76 16 14 12 14 00 12 00 3 94 059 T 76 TP 80 T 100 TP 100 T 125 TP 132 T 61 65 70 TP 78 CT T TP Rev24 indd 62 15 01 18 15 46 ...

Page 10: ...wing for dismantling and assembly 组装与分解图 CT 61 Tab 1 TAB 1IEC 60335 1 A mm 2 Corrente nominale dell apparecchio Rated current of appliance Bemessungsstrom des Gerätes 设备额定运行电流 Sezione nominale Nominal cross sectional area Nennquerschnitt 导体额定截面积 3 6 10 16 25 32 40 0 75 1 0 1 5 2 5 4 6 10 6 10 16 25 32 40 63 13 1 Minimum cross sectional area of conductors CT T TP Rev24 indd 63 15 01 18 15 46 ...

Page 11: ...gnetic compatibility Standards EN ISO 12100 2010 EN IEC 60204 1 2006 EN 809 A1 C1 Additional information No further details Declaration We hereby declare under our sole responsibility that the product s mentioned above to which this declaration relates complies with the above mentioned standards and Directives BEDU Pompen BV Poort van Midden Gelderland Rood 10 6666 LT Heteren Tel 31 0 88 4802 900 ...

Page 12: ......

Page 13: ...orking from our own workplace or at your location A fast and appropriate solution for all your issues Wide range of liquid pumps Repair maintenance and revision made for your process BEDU POMPEN B V Poort van Midden Gelderland Rood 10 6666 LT HETEREN Nederland Telefoon 31 0 88 4802 900 E mail info bedu eu WWW BEDU EU BEDU BELGIUM B V B A Industriepark West 75 9100 SINT NIKLAAS België Telefoon 32 0...