BECKWITH ELECTRIC M-2001D Quick Start Manual Download Page 4

If Memory Card is present, the first menu 

displayed under Communication is the 

Memory Card menu, otherwise the 

Memory Card menu is not displayed.

If IEC 61850    is purchased

COMMUNICATION

CNFG

UTIL

Memory Card

Load Setpoints

Press ENT to begin

Save Setpoints
Press ENT to begin

Save Datalog
Press ENT to begin

Save seq. of events

Press ENT to begin

Save oscillograph

Press ENT to begin

Clone save
Press ENT to begin

Clone load
Press ENT to begin

Load DNP Config

Press ENT to begin

Save DNP Config

Press ENT to begin

Save Metering Data
Press ENT to begin

Firmware Update
Press ENT to begin

Load IEC config
Press ENT to begin

Save IEC Config

Press ENT to begin

SD Quick Capture

Press ENT to begin

Comm Settings

Comm1 Port Type

RS485

Comm2 Port Type
RS232

Comm Protocol
DNP3.0

DNP Configuration

M2001D DNP DEFAULT

CID File ID

M2001D DEFAULT

Src Addr Validation
disable

Substation Address
DNP x

Feeder Address

DNP x

Comm Address

DNP x  Mdbus x

Baud Rate
9600

Parity
NONE

Stop Bits

ONE STOPBIT

Sync Time

    x mS

Output Pulse

x.x  Sec

Comm Access Security
disable

Comm Access timeout

xx sec

TX Delay

xx ms

Heartbeat Option
Disabled

Protocol

MODBUS

Baud Rate
115200

Parity
NONE

Stop Bits

TWO STOPBITS

Sync Time

   xx mS

RS232

Bluetooth Enable

ENABLE

Bluetooth Reset
Ready Press ENTER

Bluetooth Protocol
MODBUS

Authentication

disable

Friendly Name

M2001D-1

Bluetooth Pass Reset
Ready Press ENTER

Control BT Device
XX:XX:XX:XX:XX:XX

Bluetooth Mode

MODE0

Bluetooth

Set LCD Contrast: E

************

User Line 1

E

Beckwith Electric

User Line 2

E

M-2001D

Level 1 Access Code

Press ENT to change

Level 2 Access Code

Press ENT to change

Clear Osc Records
Ready Press ENTER

Oscillograph Message
ENABLE

HMI

DHCP Enable

ENABLE

IP Address
0.0.0.0

Net Mask
0.0.0.0

Gateway

0.0.0.0

Enter Modbus Port

  502

Enter DNP Port
20000

Auto Negotiation
ENABLE

Keepalive time

7200  sec

Ethernet

Radius Server 1 IP

x. x. x. x

Radius Server 2 IP

x. x. x. x

Radius 1 Auth. Port

  1812

Radius 2 Auth. Port

1814

Radius Secret Code
Press ENT to change

IEEE 1686 Standard
not used/

Authen with Encryp*

Radius 1 Acc. Port

  1813

Radius 2 Acc. Port

  1815

Radius En./Dis.
disable

IPSEC En./Dis.

disable

Load User config
Press ENT to begin

Load IPsec config

Press ENT to begin

SNTP Enable
disable

SNTP Server Address

0.0.0.0

Time Zone GMT

–5 Hr

UTILITIES

COMM

MNTR

Bias Voltage    

Status/Test Mode

Load Voltage

XXX.X Volts

Voltage Offset

X

Volt Cal Coefficient

32767 X

Volt RMS Coefficient

 32762 X

Control Load I

x.x mA   Lag/Lead

Curr Cal Coefficient

 32767 X

Power Factor

x.xxx  Lag/Lead

I Sin Coefficient

0  X

I Cos  Coefficient

8192  X

Motor Current

x.xx  mA

Mtr Cal. Coefficient

  8192  X

Mtr Sin Coefficient

     0  X

Mtr Cos Coefficient

   8192  X

Calibration/Test

Mtr RMS Coefficient

  8192  X

Circ Cal. Coefficien

 32767  X

Circ Sin Coefficient

0  X

Circ Cos Coefficient

   8192  X

LED Scroll Test

Press ENT to begin

Input Test

Press ENT to Begin

Output Test

Press ENT to test

Button Input Test

Press ENT to Begin

Change Src Input   

press ENTER.

Watchdog resets:  x

Total resets:  xx

Clear reset counters

Press ENT to begin

X1 Duration

0  ms,  Avg:    0 ms

Alarm Activity

Press ENT to Begin

About

Serial Number

xxxxx

Firmware Version

D-0214VXX.XX.XX

EE Checksum

XxXXXx

Last Loaded File CRC

x.x

Hardware Number

   x

Comm Options En/Dis

11101111111111

Sheet 4 of 4

800-M-2001D-QSG-08 (

0

3

-17

)

CONFIGURATION

SETP       COMM

SETPOINTS

MNTR       CNFG

MONITOR

UTIL       SETP

© 2011 Beckwith Electric Co. All Rights Reserved

Technical Support

www.beckwithelectric.com / 727 544-2326

Email Support: [email protected]

*NOTE: 

Once IEEE 1686 Standard cyber security is enabled, 

the user must enter a valid User Name and Password to
access any menus other than the "Utilities/About" menu. This
selection cannot be changed to "not used" without entering
a valid User Name and Password.

At any menu screen:

Press EXIT to go to the Menu Header.

Press either 

 

 to move sideways to the adjacent Menu Header.

Summary of Contents for M-2001D

Page 1: ... Switch type then the Self Test Alarm relay is NOT available T X Bottom View Top View Front Fiber Optic V Pin Connector optional Fiber Optic ST Connector RJ 45 Ethernet over Copper optional Control Power Backup Input BlueTooth Ethernet over Fiber Optic optional RS 485 RS 232 DE9S In Line 6 Pin Connector for the M 2025B C or D Current Loop Module 24 Pin Blue Connector for M 2000 Series Adapter Pane...

Page 2: ...x Min Min Load Voltage E x x Volts Max Load Voltage E xxx x Volts Max Pri Current E xxx x Amps Max Primary Watts E x xx MW Max Primary VArs E x xx MVAr Max Primary VA E x xx MVA PF Max VA E x xxx PF Press ENT to reset Demand History Press ENT to perform Master Reset Watt Hours Fwd E x kWh Lagging VAr Hours E x kVArh Watt Hours Rev E xx kWh Leading VAr Hours E x kVArh Press ENT to reset Energy Mete...

Page 3: ...rent Block disable Paralleling Tap Limits ENABLED Not settable unless an external source of Tap Position is selected Tap Position Cal DISABLE Tap Information disable Tap Block Raise xx Tap Block Lower xx Highest Tap xx Lowest Tap xx Intertap Delay x Sec Seal in Fail Block ENABLE Op Counter Config 1 X 2 X COUNT WINDOW CAM FOLLOWER Cam Follower disable X Mode Delay xx ms Op Counter Preset xxxxxx Ntr...

Page 4: ...ime 7200 sec Ethernet Radius Server 1 IP x x x x Radius Server 2 IP x x x x Radius 1 Auth Port 1812 Radius 2 Auth Port 1814 Radius Secret Code Press ENT to change IEEE 1686 Standard not used Authen with Encryp Radius 1 Acc Port 1813 Radius 2 Acc Port 1815 Radius En Dis disable IPSEC En Dis disable Load User config Press ENT to begin Load IPsec config Press ENT to begin SNTP Enable disable SNTP Ser...

Reviews: