background image

M-2910 BlueJay Universal Data Transceiver

–6–

Environmental

Temperature

: Proper operation maintained from –40°C to +80°C.

Humidity

: Proper operation is maintained up to 95% relative humidity  (non-condensing).

Environmental Protection

: The power supply printed circuit board is conformally coated to inhibit fungus

growth.

Enclosure

: 1/16" Aluminum.

Physical

Size:

 5.71" high (with antenna 8.88") x 3.72" wide x 2.06" deep (14.5 cm (22.6) x 9.5 cm x 5.23 cm). See

Figure 7 for dimensional drawing.

Weight:

5.1 oz (145.35 grams)

Enclosure meets requirements of  IP30.

Safety and Cautions

8

WARNING

:

 The installation, maintenance, and/or operation of this equipment could present

potentially unsafe conditions, including, but not limited to, electrical shock or improper voltage to
components. Improper operation could cause personal injury, death, or damage to property.

Read all safety instructions before operating the M-2910, and retain them for further reference. Follow all
operating and usage instructions, and make special note of the following safety symbols:

This sign warns that the area is connected to a dangerous high voltage, and you must
never touch it.

This sign means that you should refer to the corresponding section of the operation
manual for important information before proceeding.

Do not attempt to perform maintenance or service functions that are not described in the operating
instructions. Instead, refer all such service requirements to Beckwith Electric Co., Inc. Unit must be returned
for service in secure (preferably original) packaging. Shipping cost must be paid by user.

Only the antenna provided is authorized for use with the M-2910. If the antenna is lost or damaged, please
contact Beckwith Electric Co., Inc. to secure a replacement antenna.

This product generates, uses, and can radiate radio frequency (RF). If it is not installed and used in
accordance with the operating instructions, it can cause harmful interference to communications. If this
equipment causes harmful interference to radio or television reception, the user should try and correct the
interference by:

Reorienting or relocating the receiving/transmitting antenna

Increasing the separation between the equipment and the M-2910

Connecting the equipment into an outlet on a different circuit from the M-2910.

If these do not correct the interference, consult an experienced radio/television technician for assistance.
Correcting such interference is the responsibility of the user, not the manufacturer.

Summary of Contents for BlueJay M-2910

Page 1: ...t and master slave high speed 1 Mbps data transmission rates at ranges up to 1500 feet Interfaces using high speed Synchronous Peripheral Interface SPI Baud rates up to 500 kbps Substation hardened to withstand temperatures from 40 to 80 degrees C and humidity up to 95 No user license required interfaces with SPI interface equipped IEDs ...

Page 2: ...is not installed and used in accordance with the operating instructions it can cause harmful interference to communications If this equipment causes harmful interference to radio or television reception the user should try and correct the interference by Reorienting or relocating the receiving transmitting antenna Increasing the separation between the equipment and the M 2910 Connecting the equipm...

Page 3: ...e Communication The M 2910 conditions the data and transmits it over a half duplex direct sequence spread spectrum radio operating in the 2 4 GHz ISM band The over the air data rate is 1 Mbps Transmit Frequency Range 2400 MHz to 2483 5 MHz Output Power 30 mW Modulation DBPSK Occupied Bandwidth 20 MHz Spurious Emissions 50 mV meter Harmonic Emissions 500 uV meter Spreading Method Direct Sequence 11...

Page 4: ... Configuration The M 2910 is configurable using parameters set into the M 2600A M 2667A using SlimCom The following parameters can be set Wireless Source unit Address 1 250 Wireless Destination Transmit Address 1 255 Wireless Multicast Receive Address 251 254 Peer to Peer Unit Addresses 1 250 Configuring the M 2910 To configure the M 2910 the unit must be installed on an M 2600A M 2667A control an...

Page 5: ...M 2910 BlueJay Universal Data Transceiver Figure 7 M 2910 Outline Dimensions Ma de in U S A 4 51 U 2205 166 4 PLACES 65 1 06 5 71 4 08 3 72 3 14 20 81 M 2910 BlueJay WIRELESS T M CO INC EL ECT RIC BECKWITH ...

Page 6: ...t This sign means that you should refer to the corresponding section of the operation manual for important information before proceeding Do not attempt to perform maintenance or service functions that are not described in the operating instructions Instead refer all such service requirements to Beckwith Electric Co Inc Unit must be returned for service in secure preferably original packaging Shipp...

Page 7: ...instruction manual may cause harmful interference to radio communica tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interfer...

Page 8: ...Printed in U S A 06 11 03 I S O 9 0 0 1 2000 Regis t e r e d BECKWITH ELECTRIC CO INC 6190 118th Avenue North Largo Florida 33773 3724 U S A PHONE 727 544 2326 FAX 727 546 0121 E MAIL marketing beckwithelectric com WEBPAGE www beckwithelectric com ...

Reviews: