,1'8675,((/(.7521,.
Eiserstraße 5 / D-33415 Verl / Tel.: +49 (0)5246/963-0 / Fax: -149
2SHUDWLQJ,QVWUXFWLRQV
Modular Industrial Computer MIC3210
3
0,&
'RQRWXVHWKH3&RXWRI
GRRUV
7KH,QGXVWULDO3&PXVWQRWEHXVHGRXWRIGRRUV
'XULQJRSHUDWLRQWKHIROORZLQJWHFKQLFDOGDWDPXVWEHRE
VHUYHG
(QYLURQPHQWDOFRQGLWLRQV
$PELHQWWHPSHUDWXUH
5 to 45 °C, limited due to the restricted temperature sta-
bility of the LC display
+XPLGLW\
Maximum of 95% non-consendating
5HVLVWDQFHWRVKRFNDQG
YLEUDWLRQV
+RXVLQJ FKDVVLV
Vibrations: 5G at 10 to 55Hz
Shock resistance: 30G
'LVNGLYH
Vibrations: 0.5G at 5 to 500Hz
Shock resistance: 5G
+DUGGLVN
Vibrations: 0.5G at 17 to 500Hz
Shock resistance: 10G
/&GLVSOD\
Vibrations: 1G at 58 to 500Hz
Shock resistance: 50G
3URWHFWLRQFODVV
Front: IP65
Rear: IP30
3RZHUVXSSO\
9'&SRZHUSDFN
6XSSO\YROWDJH
24 V direct current
Permitted fluctuations: 15 to 35 V DC
0D[SRZHUGUDZ
2 A
3&IXVH
Fine-wire fuse M 3.15 A
(OHFWURPDJQHWLF
(PLVVLRQV
Conforming to EN 50081-2
FRPSDWLELOLW\
,PPXQLW\
Conforming to EN 50082-2
7UDQVSRUWDQGVWRUDJH
During transport and storage, the same values for humidity and resistance to
shock and vibrations must be observed as in operation. The resistance to shock
and vibration can be increased by transporting the Industrial PC in suitable
packaging. The ambient temperatures for storage and transport must be be-
tween -20 °C and +60°C.
2SHUDWLQJWKH,QGXVWULDO3&
6ZLWFKLQJRQWKH3&
The Industrial PC does not have its own power switch. When the machine or
installation is switched on, the Industrial PC is also started.
6ZLWFKLQJRIIWKH3&
Control software as typically used on industrial PCs allows different authoriza-
tions to be assigned to all the users. A user who is not allowed to terminate
the software, is also not allowed to switch off the Industrial PC, since data
might be lost on the hard disk if the PC is switched off while software is still
running.
If the Industrial PC is switched off while the software is writing a file to the
hard disk, this file will be destroyed. Control software normally writes some-
thing to the hard disk independently at intervals of a few seconds. This means
that the probability that you will cause damage when you switch off the PC
with the software still running is very high.