Beckhoff KL9570 Documentation Download Page 5

Foreword

KL9570

5

Version: 2.0

1

Foreword

1.1

Notes on the documentation

Intended audience

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
It is essential that the documentation and the following notes and explanations are followed when installing
and commissioning these components.
It is the duty of the technical personnel to use the documentation published at the respective time of each
installation and commissioning.

The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development.

We reserve the right to revise and change the documentation at any time and without prior announcement.

No claims for the modification of products that have already been supplied may be made on the basis of the
data, diagrams and descriptions in this documentation.

Trademarks

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

 and XTS

®

 are registered

trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.

Patent Pending

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or
registrations in various other countries.

The TwinCAT Technology is covered, including but not limited to the following patent applications and
patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.

EtherCAT

®

 is registered trademark and patented technology, licensed by Beckhoff Automation GmbH,

Germany

Copyright

© Beckhoff Automation GmbH & Co. KG, Germany.
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization are prohibited.
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a
patent, utility model or design.

Summary of Contents for KL9570

Page 1: ...Documentation KL9570 Buffer capacitor terminal 2 0 2017 10 20 Version Date...

Page 2: ......

Page 3: ...tion 8 2 2 Technical data 9 3 Mounting and wiring 10 3 1 Installation on mounting rails 10 3 2 Installation instructions for enhanced mechanical load capacity 12 3 3 Connection 13 3 3 1 Connection sys...

Page 4: ...Table of contents KL9570 4 Version 2 0...

Page 5: ...data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automation Gm...

Page 6: ...liar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions must be...

Page 7: ...1 1 0 00 0 1 00 The firmware and hardware versions delivery state can be found in the serial number printed on the side of the terminal Syntax of the serial number Structure of the serial number WW YY...

Page 8: ...rvoltages If the recovery energy exceeds the capacity of the capacitors energy can be dissipated via an external ballast resistor Functioning The KL9570 monitors the voltage between terminal points 2...

Page 9: ...t 2 point control Electrical isolation 1 500 V connection terminal point K bus Dimensions W x H x D approx 15 mm x 100 mm x 70 mm width aligned 12 mm Weight approx 65 g Permissible ambient temperature...

Page 10: ...eldbus Coupler Join the compo nents with tongue and groove and push the terminals against the mounting rail until the lock clicks onto the mounting rail If the Terminals are clipped onto the mounting...

Page 11: ...The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics and thus...

Page 12: ...ts for testing these Power Feed Terminals can be released and pulled at least 10 mm from the group of terminals WARNING Risk of electric shock The PE power contact must not be used for other potential...

Page 13: ...ief and the wire connection should be kept as short as possible A distance of approx 10 cm should be maintained to the cable duct 3 3 Connection 3 3 1 Connection system WARNING Risk of electric shock...

Page 14: ...nnection wires when the connector is removed Conductor cross sections between 0 08 mm2 and 2 5 mm2 can continue to be used with the proven spring force technology The overview and nomenclature of the...

Page 15: ...toggle 2 The wire can now be inserted into the round terminal opening without any force 3 The terminal point closes automatically when the pressure is released holding the wire securely and permanent...

Page 16: ...8 9 mm 3 3 3 Connection WARNING Risk of injury through electric shock and damage to the device Bring the Bus Terminals system into a safe de energized state before starting mounting disassembly or wir...

Page 17: ...the Bus Terminals Function The capacitor in the KL9570 compensates peaks in the supply voltage for the stepper motor DC motor As soon as this supply voltage exceeds 55 V the KL9570 activates the brake...

Page 18: ...d temperature range in potentially explosive areas Measures must be taken to protect against the rated operating voltage being exceeded by more than 40 due to short term interference voltages The indi...

Page 19: ...he Beckhoff terminal systems in potentially explo sive areas ATEX Pay also attention to the continuative documentation Notes about operation of the Beckhoff terminal systems in potentially explosive a...

Page 20: ...components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support...

Page 21: ...aching on mounting rail 10 Fig 3 Disassembling of terminal 11 Fig 4 Power contact on left side 12 Fig 5 Standard wiring 13 Fig 6 Pluggable wiring 14 Fig 7 High Density Terminals 14 Fig 8 Connecting a...

Reviews: