background image

 

Appendix 

 

FC90xx 

41 

5 Appendix 

5.1  Beckhoff Support & Service 

Beckhoff and their partners around the world offer comprehensive support and service, making available 
fast and competent assistance with all questions related to Beckhoff products and system solutions. 

5.1.1  Beckhoff branches and partner companies 

Please contact your Beckhoff branch office or partner company for 

local support and service

 on Beckhoff 

products! 

The contact addresses for your country can be found in the list of Beckhoff branches and partner 
companies: 

www.beckhoff.com

You will also find further 

documentation

 for Beckhoff components there. 

5.1.2 Beckhoff headquarters 

Beckhoff Automation GmbH 
Eiserstraße 5 
33415 Verl 
Germany 

Phone: 

+ 49 (0) 5246 / 963-0 

Fax: 

+ 49 (0) 5246 / 963-198 

e-mail: 

[email protected]

  

5.1.3 Beckhoff Support 

Beckhoff offers you comprehensive technical assistance, helping you not only with the application of 
individual Beckhoff products, but also with other, wide-ranging services: 

• 

worldwide support 

• 

design, programming and commissioning of complex automation systems 

• 

training program for Beckhoff system components 

Hotline: 

+ 49 (0) 5246 / 963-157 

Fax: 

+ 49 (0) 5246 / 963-9157 

e-mail: 

[email protected]

 

5.1.4 Beckhoff Service 

The Beckhoff service center supports you in all matters of after-sales service: 

• 

on-site service 

• 

repair service 

• 

spare parts service 

• 

hotline service 

Hotline: 

+ 49 (0) 5246 / 963-460 

Fax: 

+ 49 (0) 5246 / 963-479 

e-mail: 

[email protected]

 

If servicing is required, please quote the 

project number

 of your product. 

Summary of Contents for FC9001-0010

Page 1: ...Installation and Operating instructions for FC9001 0010 FC9011 FC9002 FC9004 FC9022 FC9062 PCI PCIe Cards for Ethernet Version 2 1 Date 2012 03 05...

Page 2: ......

Page 3: ...C9002 FC9004 PCI Ethernet 6 2 1 3 FC9062 PCIe Modul 7 2 2 Technical data 8 2 2 1 FC9001 0010 FC9011 FC9002 FC9004 8 2 2 2 FC9022 FC9062 9 2 3 Ethernet 10 2 3 1 Basic Principles 10 3 Installation 11 3...

Page 4: ...ter tab 35 4 2 1 Compatible Devices 36 4 3 EtherCAT tab 38 4 4 Statistics tab 39 4 5 Diagnostics tab 40 5 Appendix 41 5 1 Beckhoff Support Service 41 5 1 1 Beckhoff branches and partner companies 41 5...

Page 5: ...scriptions in this documentation 1 1 2 Trademarks Beckhoff TwinCAT EtherCAT Safety over EtherCAT TwinSAFE and XFC are registered trademarks of and licensed by Beckhoff Automation GmbH Other designatio...

Page 6: ...in the operation manual is in good condition and complete and always available for reference at the location of the product none of the safety and warning notes attached to product are removed and tha...

Page 7: ...its plug and play interface 10 100 1 000 Mbit s FC9011 FC9022 10 100 Mbit s FC9001 0010 full duplex automatic baud rate setting according to IEEE 802 3u maximum performance through hardware integrated...

Page 8: ...llowing benefits plug and play interface 10 100 Mbit s full duplex automatic baud rate setting according to IEEE 802 3u for each channel maximum performance through hardware integrated checksum creati...

Page 9: ...A module can therefore provide two Gigabit Ethernet interfaces for example The FC9062 module complements the slide in IPC C5210 the Panel PC CP62xx and the control cabinet IPCs C6515 C6525 and C6930...

Page 10: ...ink Speed Green 100MBit Orange 1GBit Activity Interface to the PC 32 Bit Plug and Play PCI Interface Standard driver standard operating system drivers for Intel compatible NIC Standard driver for Inte...

Page 11: ...Plug And Play Standard driver Standard driver for Intel 82574L series or Beckhoff driver for Windows 2000 XP Win7 Drivers can be selected separately for each channel Real time driver TwinCAT driver fo...

Page 12: ...d assigning MAC IDs segmentation and routing Like the Ethernet protocol IP does not guarantee that the data is transported data packets can be lost or their sequence can be changed TCP IP was develope...

Page 13: ...at the Ethernet card cannot come into contact with other plug in cards or memory components etc 5 Close the PC case 6 Connect the Ethernet cables with the optical fibre connections of the Ethernet car...

Page 14: ...ards that have no Intel chip set It supports no hard real time and may cause jitter Further information about TwinCAT RT Ethernet Intermediate Driver may be found in the TwinCAT Information System 3 2...

Page 15: ...ernet card Installation under Windows 2000 and Windows XP Note All screen shots of this documentation are made under Windows 2000 Under Windows XP the TwinCAT driver is installed in the same way After...

Page 16: ...Installation Allow the assistant to search for a suitable driver The TwinCAT driver for real time Ethernet is included with the Beckhoff TwinCAT automation software 14 FC90xx...

Page 17: ...r real time Ethernet in the driver database on the hard disk of your PC Operation of the TwinCAT drivers for real time Ethernet requires no digital signature from Microsoft Beckhoff has thoroughly tes...

Page 18: ...real time Ethernet was installed successfully for an Ethernet port Exit the installation with Finish If you are using a multi channel Beckhoff Ethernet card repeat the driver installation procedure fo...

Page 19: ...et Protocol see chapter Activating the TwinCAT Ethernet protocol 3 3 1 Resources Example for the resources of an FC900x under Windows 2000 Control Panel System Hardware Device Manager Network adapters...

Page 20: ...shots of this documentation are made under Windows 2000 Under Windows XP the TwinCAT driver is installed in the same way Click t al the right bottom side of the Windows taskbar on the TwinCAT icon an...

Page 21: ...and the TwinCAT Ethernet Protocol for the chosen device Operation of the TwinCAT drivers for real time Ethernet requires no digital signature from Microsoft Beckhoff has thoroughly tested this driver...

Page 22: ...Installation The TwinCAT driver for real time Ethernet and the belonging TwinCAT Ethernet Protocol were installed Activate the Show Bindings Check Box to display the bounded protocol 20 FC90xx...

Page 23: ...all Software Note Install the Beckhoff TwinCAT automation software before installing the Beckhoff Ethernet card Installation under Windows 2000 and Windows XP Note All screen shots of this documentati...

Page 24: ...Installation Click on Configure 22 FC90xx...

Page 25: ...rd If you wish to select the associated driver yourself select the option to display a list of all known drivers If the Beckhoff TwinCAT automation software is already installed the Add New Hardware W...

Page 26: ...ers for real time Ethernet requires no digital signature from Microsoft Beckhoff has thoroughly tested this driver in conjunction with the supported hardware and has verified compatibility with Window...

Page 27: ...TwinCAT driver for real time Ethernet was installed successfully Exit the installation with Finish Now you have to activate the TwinCAT Ethernet Protocol see chapter Activating the TwinCAT Ethernet pr...

Page 28: ...stallation 3 5 1 Resources Example for the resources of an FC900x under Windows 2000 Control Panel System Hardware Device Manager Network adapters TwinCAT Intel PCI Ethernet adapter Resources 26 FC90x...

Page 29: ...the TwinCAT Ethernet protocol has to be activated for the Beckhoff Intel PCI Ethernet card Under Start Settings Control Panel Network and Dial up Connections click on the LAN connection for which you...

Page 30: ...Installation Select Protocol not Service and click on Add Under Beckhoff select the option TwinCAT Ethernet Protocol and click OK 28 FC90xx...

Page 31: ...der Tools Folder Options View Show content of system folders Hidden files and folders Show all files and folders Controlling real applications with TwinCAT Ethernet Protocol Attention For controlling...

Page 32: ...winCAT Ethernet Protocol can be started by issuing can the command net start TcEther in a DOS Command Prompt or by restarting the PC The TwinCAT Ethernet Protocol will be started whenever the PC is re...

Page 33: ...e branch I O Configuration I O devices or via the magic wand button in the button bar The system manager will search for I O devices e g fieldbus cards installed on the PC In the example shown the FC9...

Page 34: ...search the FC9004 channels for boxes Bus Couplers Bus Terminal controllers or Fieldbus Box modules The system manager now wants to activate Free Run mode Click on Yes The system manager will now disp...

Page 35: ...ab Diagnostics tab are now available for configuring this Ethernet channel Numbering of the Ethernet channels Note The system manager numbers the Ethernet channels device 1 device 2 in the order in wh...

Page 36: ...the system manager You may change it Type Device type Comment Here you can save a free comment text Disabled This control box can be used to disable the Ethernet channel Create Symbols If this contro...

Page 37: ...e cycle time for Free Run mode Locking I O after link error If this control box is activated process data exchange is not automatically restarted after a link error has been rectified e g after pullin...

Page 38: ...d devices without required binding to TwinCAT Ethernet For the fieldbus cards fieldbus card channels displayed here the TwinCAT driver for real time Ethernet is installed but the TwinCAT Ethernet prot...

Page 39: ...to be the best drivers for this hardware which means that it may overwrite the TwinCAT driver for real time Ethernet Remedy Automatic Windows Updates can be disabled For manual updates the suggestion...

Page 40: ...he device is switched on INIT Initiate PRE OP Pre Operation SAFE OP Safe Operation OP Operation Export Configuration File This button can be used to save the configuration information in an XML file f...

Page 41: ...ows the number of EtherCAT frames sent and the number of frames sent per second Recv Frames Shows the number of EtherCAT frames received and the number of frames received per second Missed Frames Show...

Page 42: ...ate PRE OP Pre Operation SAFE OP Safe Operation OP Operation CRC A Cyclic Redundancy Check at the incoming EtherCAT connection CRC B Cyclic Redundancy Check at the outgoing EtherCAT connection CRC C C...

Page 43: ...khoff Automation GmbH Eiserstra e 5 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com 5 1 3 Beckhoff Support Beckhoff offers you comprehensive technical assistanc...

Reviews: