6.2

Accessories

Mounting

Ordering information

Description

ZS5300-0001

Mounting rail (500 mm x 129 mm)

Labeling material, protective caps

Ordering information

Description

ZS5000-0010

Protective cap for M8 sockets, IP67 (50 pieces)

ZS5100-0000

Inscription labels, unprinted, 4 strips of 10

ZS5000-xxxx

Printed inscription labels on enquiry

Cables

A complete overview of pre-assembled cables for EtherCAT Box modules can be found 

here

.

Ordering information

Description

ZK2020-3xxx-xxxx

Power cable M8, 4-pin 

link to the website

ZK700x-xxxx-xxxx

EtherCAT P cable M8 

Link to website

Tools

Ordering information

Description

ZB8801-0000

Torque wrench for plugs, 0.4…1.0 Nm

ZB8801-0001

Torque cable key for M8 / wrench size 9 for ZB8801-0000

Further accessories

Further accessories can be found in the price list for fieldbus components from Beckhoff and online
at 

https://www.beckhoff.com

.

Summary of Contents for EPP1332-0001

Page 1: ...Documentation EN EPP1332 0001 EPP1342 0001 EtherCAT P junctions 2020 09 22 Version 1 2...

Page 2: ......

Page 3: ...4 4 1 Mounting 14 4 1 1 Dimensions 14 4 1 2 Fixing 15 4 1 3 Functional earth FE 15 4 1 4 Tightening torques for plug connectors 15 4 2 EtherCAT P 16 4 2 1 Connection 16 4 2 2 EtherCAT P LEDs 17 4 2 3...

Page 4: ...Table of contents EPP1332 0001 EPP1342 0001 4 Version 1 2...

Page 5: ...modification of products that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT G EtherCAT G...

Page 6: ...ed for trained specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instructi...

Page 7: ...ocumentation was written The module features are continuously improved and developed further Modules having earlier production statuses cannot have the same properties as modules with the latest statu...

Page 8: ...ated from each other and can therefore be switched individually The nominal supply voltage for both is 24 VDC EtherCAT P uses the same cable structure as EtherCAT a 4 core Ethernet cable with M8 conne...

Page 9: ...utes the incoming EtherCAT P signal to three output ports Feed in point for refreshing the supply voltages A refresh of the supply voltages may be necessary in EtherCAT P networks with long cables and...

Page 10: ...x protective cap for supply voltage input M8 transparent pre assembled 1x protective cap for supply voltage output M8 black pre assembled 10x labels blank 1 strip of 10 Pre assembled protective caps d...

Page 11: ...rts 3 2 1 Scope of supply Make sure that the following components are included in the scope of delivery 1x EtherCAT P Box EPP1342 0001 4x protective cap for EtherCAT P socket M8 red pre assembled 10x...

Page 12: ...the module electronics From the control voltage US via the feed connector X60 19 From the control voltage US via the EtherCAT P port X50 Current consumption of the module electronics typically 65 mA...

Page 13: ...0001 EPP1342 0001 13 Version 1 2 3 4 Process image The process image of the EPP1332 0001 and EPP1342 0001 modules is identical The process image of EPP1332 0001 is shown here as an example Fig 4 Proce...

Page 14: ...in millimeters Housing features Housing material PA6 polyamide Sealing compound polyurethane Mounting two fastening holes 3 5 mm for M3 Metal parts brass nickel plated Contacts CuZn gold plated Insta...

Page 15: ...the fastening holes in the corners of the module The fastening holes have no thread 4 1 3 Functional earth FE The upper fastening hole also serves as a connection for functional earth FE Make sure tha...

Page 16: ...P coding for EtherCAT P forwarding Fig 7 EtherCAT P connector on EtherCAT P Box Fig 8 Pin assignment M8 EtherCAT P In and EtherCAT P Out Pin assignment The contacts of the EtherCAT P coded M8 connecto...

Page 17: ...Lit LINK connection to the following EtherCAT P module flashing ACT Communication with the following EtherCAT P module Run off Status of the EtherCAT P module is Init flashes quickly Status of the Eth...

Page 18: ...ust also be taken into account This ensures that the connected consumers sensors and actuators are operated within the permitted voltage range The voltage calculation tool integrated in TwinCAT can be...

Page 19: ...e 1 Control voltage Us 24 VDC 2 Peripheral voltage Up 24 VDC 3 GNDs 4 GNDp The contacts of the M8 connectors can conduct a maximum current of 4 A Control voltage US Power is supplied to the fieldbus t...

Page 20: ...so for the redirection of the supply voltages US and UP the maximum permissible current for M8 connectors of 4 A must not be exceeded 4 3 2 Status LEDs IP 67 modules have two status LEDs which indicat...

Page 21: ...four wires for signal transmission Thanks to automatic line detection Auto MDI X both symmetrical 1 1 or cross over cables can be used between Beckhoff EtherCAT Detailed recommendations for the cabli...

Page 22: ...describes the assignment of the connectors of EPP1332 0001 and EPP1342 0001 to their representation in TwinCAT This assignment is required to correctly map an EtherCAT network in TwinCAT offline conf...

Page 23: ...n in the IO tree Example Moving a previously added EtherCAT P Box to another connector 1 Double click the EtherCAT P Box in the IO tree e g an EPP1008 0001 that was previously connected to X52 2 Click...

Page 24: ...ter protection Definition 0 Non protected 1 Protected against water drops 2 Protected against water drops when enclosure tilted up to 15 3 Protected against spraying water Water sprayed at an angle up...

Page 25: ...ion labels on enquiry Cables A complete overview of pre assembled cables for EtherCAT Box modules can be found here Ordering information Description ZK2020 3xxx xxxx Power cable M8 4 pin link to the w...

Page 26: ...naged by Beckhoff In principle a device with a higher revision can replace a device with a lower revision unless specified otherwise e g in the documentation Associated and synonymous with each revisi...

Page 27: ...O PCB u hardware version of the I O PCB Example D 22081501 calendar week 22 of the year 2008 firmware version of bus PCB 1 hardware version of bus PCB 5 firmware version of I O PCB 0 no firmware neces...

Page 28: ...2 0001 28 Version 1 2 Fig 15 EK1100 EtherCAT coupler standard IP20 IO device with serial batch number Fig 16 CU2016 switch with serial batch number Fig 17 EL3202 0020 with serial batch number 26131006...

Page 29: ...al number 158102 Fig 19 EP1908 0002 IP67 EtherCAT Safety Box with batch number date code 071201FF and unique serial number 00346070 Fig 20 EL2904 IP20 safety terminal with batch number date code 50110...

Page 30: ...ing on the product it can be found in the following places on the packaging unit directly on the product if space suffices on the packaging unit and the product The BIC is machine readable and contain...

Page 31: ...dentifiers are used by Beckhoff and serve internal processes Structure of the BIC Example of composite information from item 1 to 4 and 6 The data identifiers are marked in red for better display BTN...

Page 32: ...Beckhoff components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 5246 963 0 Fax 49 5246 963 198 e mail info beckhoff com Beckhoff Support Su...

Page 33: ......

Page 34: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com...

Reviews: