Operation
EL1918
43
Version: 1.2.0
4.5
Diagnosis
4.5.1
Status LEDs
Fig. 29: Status LEDs
LED
Color
Description
Input 1
green
Status display for the respective input
LED lights up: Input is set
LED not lit: Input is not set
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
Input 8
4.5.2
Diagnostic LEDs
Diagnostic LEDs
LED
lit
flashing
off
Diag 1
(green)
Environment variables,
operating voltage and internal
tests are in the valid range
• If Diag 2 flashes, a logic
error code applies
-
Environment variables,
operating voltage and internal
tests are outside the valid
range
• If Diag 2 flashes, an
environment error code
applies
Diag 2
(red)
Together with Diag 3 and 4:
Global shutdown
1)
has
occurred. (see diag history of
the TwinSAFE components)
Logic or environment error
code according to Diag1 and
tables below is output
Together with Diag 3 and 4:
Global fault
1)
has occurred. (see
diag history of the TwinSAFE
components)
Diag 3
(red)
Global fault or global shutdown
on µC1
1)
-
No global fault or global
shutdown on µC1
1)
Diag 4
(red)
Global fault or global shutdown
on µC2
1)
-
No global fault or global
shutdown on µC2
1)
Summary of Contents for EL1918
Page 2: ......
Page 54: ...Appendix EL1918 54 Version 1 2 0 5 2 Certificates...