Operation
EK1960
76
Version: 1.3.1
NOTE
Power supply during download
Make sure that the TwinSAFE Logic is not switched off during the download. This can lead to unexpected
behavior or permanently disable the TwinSAFE Logic.
WARNING
Execution of the safety application
During a login or download of a safety application, the execution of the current project is stopped on the
TwinSAFE Logic.
Fig. 80: Download Project Data – The Login dialog
In the
Download Project Data
dialog specify the user name, the serial number of the EL6910/EJ6910 or the
logic component onto which the project is to be loaded, and the user password. The default user name is
Administrator,
the default-password is
TwinSAFE
. Use the
Next
button to move to the next dialog.
Fig. 81: Download Project Data – The Select Project Data dialog
In the
Select Project Data
dialog select
Complete Project Data
to load the whole project onto the EL6910/
EJ6910 or the logic component. Use the
Next
button to move to the next dialog.
Summary of Contents for EK1960 Series
Page 1: ...Operating Instructions for EK1960 TwinSAFE Compact Controller 1 3 1 2019 01 28 Version Date...
Page 2: ......
Page 6: ...Table of contents EK1960 6 Version 1 3 1...
Page 58: ...Operation EK1960 58 Version 1 3 1 Fig 51 Safety parameters of the input modules...
Page 140: ...Appendix EK1960 140 Version 1 3 1 5 2 Certificates...