Product overview
CPX27xx-0010
18
Version: 0.2
4.3
Description of the interfaces
1
4
2
3
5
6
7
Fig. 5: Interfaces of the Panel PC CPX27xx-0010.
Nr
Interface
Nr
Interface
1
5
2
6
3
7
4
4.3.1
Power supply (X101)
Conductive cross-section
The connector is specified for 8 A and can lift conductive cross-sections of 0.2 … 1.5 mm
2
.
The power supply for the Panel PC is established via the socket (X101). The power supply connector is
included in delivery.
The power supply and the external circuit of the Panel PC are connected via the 4-pole plug connector
(Phoenix DFMC 1,5/2-STF-3,5 BK – 1708595):
PS
GND
PC_O
N
24V +
Fig. 6: Power supply X101 of the CPX27xx-0010.
Table 2: Power supply (X101), pin assignment.
Pin
Function
Pin
Function
PS
Power-Status Output
PC_ON PC_ON Input
GND
0 V
24V +
Power Supply
4.3.2
LAN1, LAN2 (X103, X104)
X103, X104
Connection via standard-RJ45-cabel
The RJ-45 connectors (
X103
,
X104
) allow the PC to be connected to a 100/1000 BASE-T Local Area
Network (LAN).
Optional a third LAN port X102 is available.