Foreword 

 

1.2  Description of safety symbols 

The following safety symbols are used in this operating manual. They are intended to alert the reader to 
the associated safety instructions. 

Acute risk of injury! 

 

DANGER 

If you 

do not

 adhere the safety advise adjoining this symbol, there is immediate 

danger to life and health of individuals! 

 

Risk of injury! 

 

WARNING 

If you 

do not

 adhere the safety advise adjoining this symbol, there is danger to life and 

health of individuals! 

 

Hazard to individuals! 

 

CAUTION 

If you 

do not

 adhere the safety advise adjoining this symbol, there is obvious hazard to 

individuals! 

 

Hazard to devices and environment 

 

Attention 

If you 

do not

 adhere the notice adjoining this symbol, there is obvious hazard to 

materials and environment. 

 

Note or pointer 

 

Note 

This symbol indicates information that contributes to better understanding. 

 

CP27xx 

Summary of Contents for CP27 Series

Page 1: ...Installation and Operating instructions for CP27xx Fanless multi touch built in Panel PC Version 1 1 Date 2018 11 23...

Page 2: ......

Page 3: ...Appropriate Use 9 2 3 Access to the connectors 9 2 4 Interfaces 10 2 4 1 DVI I out Digital Visual Interface X103 10 2 4 2 USB output X104 X107 10 2 4 3 Network connection LAN1 LAN2 X 108 X109 10 2 4 4...

Page 4: ...uctions 21 4 1 Switching the Panel PC on and off 21 4 1 1 Switching on 21 4 1 2 Shutting down and switching off 21 4 1 3 First switching on and driver installation 21 4 2 Operation 21 4 3 Servicing an...

Page 5: ...Table of contents 9 3 FCC Approvals for the United States of America 28 9 4 FCC Approval for Canada 28 CP27xx 3...

Page 6: ...C and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could vi...

Page 7: ...duals Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safet...

Page 8: ...all parts of the equipment must first be switched off after which the Panel PC is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of the Panel...

Page 9: ...t Do not open the housing of the Panel PC Note For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Panel PC is used nation...

Page 10: ...ion With their highly integrated 3 inch motherboards the CP27xx built in Industrial PCs represent a high performance platform for machine construction and plant engineering applications The multi touc...

Page 11: ...ering A multi touch display is accommodated in an aluminium housing The Panel PC is installed in the front of control cabinets Risk of explosion Danger The Panel PC must not be used where there is a r...

Page 12: ...d 2 4 3 Network connection LAN1 LAN2 X 108 X109 The RJ 45 connectors X108 X109 allow the PC to be connected to a 10 100 1000BASE T Local Area Network LAN 2 4 4 Power Supply X110 The power supply for t...

Page 13: ...type recommended by the manufacturer Notice correct polarity 2 6 Extension for PCIe plug in cards When ordered with the corresponding option the Panel PC can be extended by one additional plug in card...

Page 14: ...ture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hour...

Page 15: ...n the Panel PC in such a way that reflections on the screen are avoided as far as possible Use the position of the screen as a guide for the correct installation height it should be optimally visible...

Page 16: ...ping levers For the cutout dimension of the Panel PC see chapter Technical Data the wall thickness is between 1 mm and 5 mm 1 Insert the Panel PC into the cutout 2 Release the clamping levers with a 3...

Page 17: ...the Industrial PC is provided with a power supply unit with integrated UPS order option you can realize an uninterruptible power supply UPS using the battery pack C9900 U330 Danger of Explosion WARNIN...

Page 18: ...hat indicates that the process is complete and that the main voltage can be switched off This can be done manually via a signal lamp connection or via a contactor With this solution the main switch ge...

Page 19: ...ft conductive cross sections until 1 5 mm2 So the connector is fitted to the cable 1 Strip insulation from the cable ends Length of stripped conductor is 8 9 mm 2 Screw together the cable ends in the...

Page 20: ...nal 24 V power supply Use same type of rechargeable battery Attention If a 24 V UPS is installed the same type of rechargeable battery must be used 3 5 3 Configuration for shutting down the PC The con...

Page 21: ...n after a power failure The maximum load is 1 4 A Once the PC has been de energized via the UPS software the UPS output is switched to 0 V Any connected panel is thus switched off and total discharge...

Page 22: ...rom the power supply Connect all cables at the Panel PC and at the devices to be connected Ensure that all screw connections between connectors and sockets are tight Reconnect all devices to the power...

Page 23: ...4 1 3 First switching on and driver installation When you switch on the Industrial PC for the first time the pre installed operating system optional will be started In this case all the required drive...

Page 24: ...ttery only with the identical type or an alternative type recommended by the manufacturer Notice correct polarity The used battery must be disposed of in accordance with national electronics scrap reg...

Page 25: ...vers can be installed from the driver CD provided To install the UPS driver software execute file Beckhoff_UPS_vx xx xx exe from the subdirectory of UPS from the CD provided on the Industrial PC Drive...

Page 26: ...ff Service Panel PC boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Panel PC Call the manufacturer of the...

Page 27: ...e Panels PC please visit our homepage Here you will find the actual drawings using the link http www beckhoff de german download technical_drawings htm Notice mounting orientation Warning The assembly...

Page 28: ...with 15 display approx 54 W with 21 5 display approx 41 W with 15 6 display approx 64 W with 24 display UL compliance in progress Interfaces 2 Ethernet adapter 10 100 1000BASE T with RJ 45 connection...

Page 29: ...Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assis...

Page 30: ...nerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equ...

Reviews: