Basic information 

 

 

BK 7000 

 

 

Configuration interface

 

 
Serial  interface  under  the 
front flap 

On the lower part of the front face  you will find the standard bus couplers 
which  are  fitted  with  an  RS232  interface.  The  miniature  plug  can  be  at-
tached to a PC by means of a connection cable and the configuration soft-
ware KS2000. This interface enables you to configure the analog channels. 
You can also access the functionality of the configuration interface via the 
fieldbus by means of the PLC interface communications. 
 

 

K-bus contacts

 

 
6 contacts at the side 
 
 
 
 
 

The  connections  between  the  bus  coupler  and  the  bus  terminals  are  ef-
fected by gold contacts at the right-hand side of the bus coupler. When the 
bus  terminals  are  plugged  together,  these  gold  contacts  automatically 
complete the connection to the bus terminals. The K bus is responsible for 
the power supply to the electronic components of the K bus in the bus ter-
minals, and for the exchange of data between the bus coupler and the bus 
terminals. Part of the data exchange takes place via a ring structure within 
the K  bus. Disengaging the K bus, for example by  pulling on  one the bus 
terminals,  will  break this circuit so that data can no  longer  be exchanged. 
However, there are mechanisms in place which enable the bus coupler to 
locate the interruption and report it. 
 

 

Supply isolation

 

3 supply groups: 
fieldbus 
K-bus 
peripheral level 

The  bus  couplers  operate  with  three  independent  supplies.  The  input 
power  supplies  the  electrically  isolated  K-bus  circuitry  in  the  bus  coupler 
and the K-bus itself. The power supply is also used to generate the operat-
ing power for the fieldbus.  
 
Note: All the bus terminals are electrically isolated from the K bus, so that 
the K-bus is completely electrically isolated. 
 

 
Setting up the power  levels 
in the bus terminal system 

Periphery level

Bus terminals

Bus coupler

Field bus

24 V DC

Terminal bus

 
 

Summary of Contents for ControlNet BK7000

Page 1: ...ControlNet Coupler BK7000 Version 0 9 1 Last change 2006 10 30...

Page 2: ...he peripheral data in the process image 12 Starting operation and diagnostics 14 Run times and reaction times 16 3 ControlNet coupler BK7000 in the ControlNet 17 Introducing the system 17 The transfer...

Page 3: ...ecked for consistency with per formance data standards or other characteristics None of the statements of this manual represents a guarantee Garantie in the meaning of 443 BGB of the German Civil Code...

Page 4: ...ted and nullify the liability of Beckhoff Automation GmbH Description of safety symbols The following safety symbols are used in this documentation They are intended to alert the reader to the associa...

Page 5: ...ven tional terminal as the cabling level in the switch cabinet the switch cabinet can be made smaller The Beckhoff bus terminal system combines the advantages of a bus sys tem with the functionality o...

Page 6: ...et Powersupply Potential 00 X0 PE PE BECKHOFF 24V 0V BK7000 ControlNet 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 x10 x1 A B Bus couplers for various fieldbus systems You can use a variety of bus coupler...

Page 7: ...y power to the peripherals The spring terminals are connected in pairs to the power contacts The power supply to the power contacts has no connec tion to the power supply of the bus couplers The power...

Page 8: ...r the power supply to the electronic components of the K bus in the bus ter minals and for the exchange of data between the bus coupler and the bus terminals Part of the data exchange takes place via...

Page 9: ...in to test the at tached bus terminals the bus terminal test and read in the configuration from which it constructs an internal structure list which is not accessible from outside If an error occurs t...

Page 10: ...s the individual housings from being removed You can remove them without effort if you first release the latching mechanism by pulling the orange tab You should carry out work on the bus terminals and...

Page 11: ...nning of a new track The bus coupler can also be used to supply power to the power contacts The power contact labeled PE can be used as protective earth or ground This contact stands proud for safety...

Page 12: ...voltage capacity 500 Veff power contact supply voltage field bus Weight approx 170g Operating temperature 0 C 55 C Storage temperature 20 C 85 C Relative humidity 95 non condensing Vibration shock res...

Page 13: ...fault settings the maximum value of the input output value is given by 7FFF hex Negative input output values such as 10V are repre sented as 8000 hex and intermediate values are correspondingly propor...

Page 14: ...ocessing digital signals but is not sufficient for transferring values longer than eight bits such as analog values The various bus sys tems guarantee consistency to the required length It is importan...

Page 15: ...free implies that commu nication with the fieldbus system is also operating correctly The red LED flashes at two different rates to indicate a fault whereby the specific error is encoded in the patte...

Page 16: ...nfiguration 7 flashing red off viewed independently link fault or no MAC frames received 8 flashing green off viewed independently temporary channel error or listen only Lowest 9 steady green viewed i...

Page 17: ...mpa ratively short and normally do not need to be considered The reaction time on the ControlNet depends on the NUT and the transfer rate K Bus reaction time The reaction time on K Bus is determined b...

Page 18: ...on simply filters the data on the network medium for the appropriate identifier Many devices can receive the same produced piece of application information from a single producing device The determini...

Page 19: ...Example station address 18 bottom rotary switch 1 top rotary switch 8 To ensure that the rotary switch setting is saved by the BK7000 it must be reset by briefing interrupting the power supply or by...

Page 20: ...status 2 bytes transport header Net T O connection parameters network connection type Point To Point fixed variable Fixed priority Scheduled priority size No of bytes word aligned of the terminal bus...

Page 21: ...fast 8 slow 17 slow 0x01 0x1010 Config buffer overflow fast 8 slow 18 slow 0x01 0x0315 Invalid segment in path fast 9 slow 1 slow 0x06 0x0000 Not all expected data sent in the connection path fast 9...

Page 22: ...mplete ly without word alignment Rule 2 All complex terminals are mapped completely without word alignment Rule 3 Analog terminals are mapped with data only other complex terminals are mapped with dat...

Page 23: ...be done only once If you aren t sure whether this has been done already skip to step 2 Select BK7000 from the list of communication products to add it to the con figuration If the BK7000 isn t in the...

Page 24: ...stead of the assembly object the BK7000 in 1771 Mode sup ports two objects the rack object for digital terminals and the 1771 generic module for anlog terminals The input and output size of the digita...

Page 25: ...annel digital output POS10 2 channel analog input POS11 2 channel analog output POS12 2 channel analog output POS13 2 channel analog input POS14 Power input terminal POS15 2 channel digital input POS1...

Page 26: ...ts Relative byte address Bit position Process image in the control unit Position in the block 4 0 I4 POS02 4 1 I4 POS02 4 2 I4 POS03 4 3 I4 POS03 4 4 I4 POS04 4 5 I4 POS04 4 6 I4 POS05 4 7 I4 POS05 5...

Page 27: ...bit 15 MSB is always 0 In this case the 12 bits of the analog value are represented in bit 14 to bit 3 The three least significant bits are of no im portance By configuration via the Profibus master...

Page 28: ...Factory settings Software version Type 0 Length Type Secondary process image The significance of the registers and status bytes is explained in the data sheets for the corresponding bus terminals The...

Page 29: ...here Beckhoff Headquarters Beckhoff Automation GmbH Eiserstr 5 33415 Verl Germany phone 49 0 5246 963 0 fax 49 0 5246 963 198 e mail info beckhoff com web www beckhoff com Beckhoff Support Support off...

Reviews: