Beckhoff C9900-M Series Installation And Operating Instruction Download Page 5

Foreword

C9900-Mxxx

5

Version: 1.0

1

Foreword

1.1

Notes on the documentation

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
It is essential that the documentation and the following notes and explanations are followed when installing
and commissioning the components. 
It is the duty of the technical personnel to use the documentation published at the respective time of each
installation and commissioning.

The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development.
We reserve the right to revise and change the documentation at any time and without prior announcement.
No claims for the modification of products that have already been supplied may be made on the basis of the
data, diagrams and descriptions in this documentation.

Trademarks

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, EtherCAT P

®

, Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

 and XTS

®

 are

registered trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.

Patent Pending

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents:
EP1590927, EP1789857, DE102004044764, DE102007017835
with corresponding applications or registrations in various other countries.

The TwinCAT Technology is covered, including but not limited to the following patent applications and
patents:
EP0851348, US6167425 with corresponding applications or registrations in various other countries.

EtherCAT

®

 is registered trademark and patented technology, licensed by Beckhoff Automation GmbH,

Germany

Copyright

© Beckhoff Automation GmbH & Co. KG, Germany.
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization are prohibited.
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a
patent, utility model or design.

Summary of Contents for C9900-M Series

Page 1: ...Installtation and Operating instruction C9900 Mxxx Built in EtherCAT button module 1 0 2018 09 19 Version Date...

Page 2: ......

Page 3: ...with 4 pin round connector 11 3 3 3 Power supply plug 11 3 3 4 Sensor cable for emergency stop 11 3 3 5 Sensor cable 90 for emergency stop 12 3 3 6 M12 EtherCAT cable for highly flexible applications...

Page 4: ...Table of contents C9900 Mxxx 4 Version 1 0...

Page 5: ...s and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT P Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH...

Page 6: ...re familiar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions m...

Page 7: ...xposed to extreme variations in tempera ture make sure that moisture condensation does not form on or inside the device 2 2 Unpacking Proceed as follows to unpack the unit 1 Remove packaging 2 Do not...

Page 8: ...e activated in the colors red green blue and white as a result of which the operator can immediately read off feedback messages that are indicated for example by a change of color or by flashing The s...

Page 9: ...ia the 4 pin M12 socket The protection class of the round connector is equivalent to the IP67 standard Pin Signal Pin Signal 1 24 V DC 3 GND 2 GND 4 24V DC 3 2 2 EtherCAT IN OUT The EtherCAT connectio...

Page 10: ...nnector Accessories Description C9900 K741 Power cable for Control Panel drag chain suitable with 90 4 pin round connector 10 m consisting of Power cable 2 x 0 75 mm conforming to UL cores color coded...

Page 11: ...Power cable for Control Panel drag chain suitable with 4 pin round connector 20 m consisting of Power cable 2 x 0 75 mm conforming to UL cores color coded Side A Round 4 pin socket Side B not used 3 3...

Page 12: ...e M12 angled 90 pin 4 pin A coded open end 5 m ZK2000 6300 0100 Sensor cable M12 angled 90 pin 4 pin A coded open end 10 m 3 3 6 M12 EtherCAT cable for highly flexible applications Accessories Descrip...

Page 13: ...Before you can use the device it must first be created in the TwinCAT System Manager Proceed as follows 1 Click at the top in the menu on File New Project and create a new TwinCAT XAE Project 2 In th...

Page 14: ...quest with Yes in order to look for boxes 6 Confirm the request whether to enable FreeRun with Yes The device is inserted as a box in the tree view and displayed with the respective inputs and outputs...

Page 15: ...Product description C9900 Mxxx 15 Version 1 0 3 5 1 C9900 M993...

Page 16: ...Product description C9900 Mxxx 16 Version 1 0 3 5 2 C9900 M994...

Page 17: ...Product description C9900 Mxxx 17 Version 1 0 3 5 3 C9900 M995...

Page 18: ...Product description C9900 Mxxx 18 Version 1 0 3 5 4 C9900 M997...

Page 19: ...Product description C9900 Mxxx 19 Version 1 0 3 5 5 C9900 M899...

Page 20: ...Mounting C9900 Mxxx 20 Version 1 0 4 Mounting 4 1 Mounting the clamp straps max 1 2 Nm max 1 2 Nm max 1 2 Nm max 1 2 Nm Max wall thickness 4 mm...

Page 21: ...Mounting C9900 Mxxx 21 Version 1 0 4 2 Mounting the push in strips Push in strips Clamping plate for push in strips The ordered push in strips are fixed behind the clamping plate...

Page 22: ...Mounting C9900 Mxxx 22 Version 1 0 4 3 Push in strips...

Page 23: ...Dimensions C9900 Mxxx 23 Version 1 0 5 Dimensions 5 1 C9900 M899...

Page 24: ...Dimensions C9900 Mxxx 24 Version 1 0 5 2 C9900 M993...

Page 25: ...Dimensions C9900 Mxxx 25 Version 1 0 5 3 C9900 M994...

Page 26: ...Dimensions C9900 Mxxx 26 Version 1 0 5 4 C9900 M995...

Page 27: ...Dimensions C9900 Mxxx 27 Version 1 0 5 5 C9900 M997...

Page 28: ...th 100 m 100BASE Tx for EtherCAT In Out Data transfer rate 100MBit Data transfer medium Industrial Ethernet cable shielded at least CAT 5 LED ring lighting of the keys Red green blue white Emergency s...

Page 29: ...9900 M993 Approx 980 g C9900 M994 Approx 980 g C9900 M995 Approx 790 g C9900 M997 Approx 710 g C9900 M899 Approx 670 g Operating temperature Operation 0 50 C Storage 20 C to 60 C Transport 20 C to 60...

Page 30: ...components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support...

Reviews: