Beckhoff C6905 Manual Download Page 5

Notes on the documentation

C6905

5

Version: 2.1

1

Notes on the documentation

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.

The following instructions and explanations must be followed during installation and commissioning of the
components. The responsible staff must ensure that the application or use of the products described satisfy
all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development. For that reason the documentation is not in every case checked for consistency with
performance data, standards or other characteristics. In the event that it contains technical or editorial errors,
we retain the right to make alterations at any time and without warning. No claims for the modification of
products that have already been supplied may be made on the basis of the data, diagrams, and descriptions
in this documentation. All illustrations shown are only examples. The configurations depicted may deviate
from the standard.

Trademarks

Beckhoff

®

, TwinCAT

®

, TwinCAT/BSD

®

, TC/BSD

 ®

, EtherCAT

®

, EtherCAT G

®

, EtherCAT G10

®

, EtherCAT P

®

,

Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

, XTS

®

 and XPlanar

®

 are registered and licensed trademarks of

Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.

Patents

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with the corresponding applications
and registrations in various other countries. The TwinCAT Technology is covered, including but not limited to
the following patent applications and patents: EP0851348, US6167425 with corresponding applications or
registrations in various other countries.

Copyright

© Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is
prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the
grant of a patent, utility model or design.

Delivery state

All the components are supplied in particular hardware and software configurations appropriate for the
application. Changes to the hardware or software configuration are permitted, provided they are within the
specified limits for power consumption and power dissipation (please refer to the respective data sheet).

Delivery conditions

In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply.

Summary of Contents for C6905

Page 1: ...Manual EN C6905 Industrial PC 7 14 2021 Version 2 1...

Page 2: ......

Page 3: ...d unpacking 17 4 2 Installation in the control cabinet 18 4 2 1 Dimensions 19 4 2 2 Installation in the control cabinet 20 4 3 Connecting the Industrial PC 21 4 3 1 Grounding of the Industrial PC 22 4...

Page 4: ...Table of contents C6905 4 Version 2 1...

Page 5: ...CAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH Other designations used in this publication...

Page 6: ...th or serious injuries WARNING Disregarding the safety notice may lead to death or serious injuries CAUTION Disregarding the safety notice may lead to minor injuries Warning of damage to property NOTE...

Page 7: ...ssipation please refer to the respective data sheet Ensure that only trained specialists with a control and automation technology background operate the Industrial PC Use by unauthorized persons can l...

Page 8: ...ustrial PC can be used for the following applications among others diverse automation and visualization tasks wide range of IoT tasks for example when used as an IoT gateway simple HMI applications ax...

Page 9: ...Access to battery and storage media 4 Protective conductor connection PE Low resistance protective earthing and functional earthing of the Industrial PC 5 DVI interface X109 Connection of a DVI capab...

Page 10: ...C is equipped with an internal capacitive 1 second UPS uninterruptible power supply this is also supplied by the voltage The 1 second UPS does not serve to back up the operating system For further inf...

Page 11: ...ort i210 connected via PCIe is usually suitable for cycle times 1 ms and for distributed clock applications with EtherCAT X103 X104 LAN2 LAN1 8 1 8 1 Fig 3 C6905_Ethernet interface pin numbering Table...

Page 12: ...B interfaces based on device generation Generation USB interfaces C6905 0010 4x USB 2 0 C6905 0020 2x USB 3 0 2x USB 2 0 1 2 3 4 4 3 2 1 5 6 7 8 9 5 6 7 8 9 1 2 3 4 4 3 2 1 5 6 7 8 9 5 6 7 8 9 4 3 2 1...

Page 13: ...Connection Pin Connection Pin Connection 1 TDMS Data 2 9 TDMS Data 1 17 TDMS Data 0 2 TDMS Data 2 10 TDMS Data 1 18 TDMS Data 0 3 TDMS Data 2 4 Shield 11 TDMS Data 1 3 Shield 19 TDMS Data 0 5 Shield...

Page 14: ...isk activity The figure shows where the LEDs are located on the Industrial PC Fig 6 C6905 Status LEDs Table 8 Meaning of the Status LEDs LED Color flashing interval Meaning PWR Power green off Compute...

Page 15: ...ple Table 9 Key name plate C6905 No Description 1 Model The last four digits indicate the device generation 2 Serial number BTN 3 Date of manufacture 4 Mainboard 5 CPU 6 Main memory 7 Storage media 8...

Page 16: ...ex factory with an internal UPS under the order designation C9900 U214 The capacitive 1 second UPS continues to supply the processor with power if the power supply fails During this period persistent...

Page 17: ...iate packaging of the Industrial PC in particular the original packaging can improve the vibration resistance during transport NOTE Hardware damage due to condensation Unfavorable weather conditions d...

Page 18: ...C is designed for installation in control cabinets in machine and plant technology Please observe the environmental conditions prescribed for the operation see Chapter 9 Technical data 36 With the hel...

Page 19: ...ng plate are used to prepare the control cabinet and to mount the device correctly in the control cabinet All dimensions are in mm Figure 10 illustrates the dimensions of the Industrial PC with the st...

Page 20: ...in the control cabinet it must be furnished with the holes for the fastening screws according to the dimensions of the PC see Chapter 4 2 1 Dimensions 19 You need M4 screws for mounting After you hav...

Page 21: ...evice To prepare the Industrial PC for operation it must be connected The first step is to ground the device Then you can connect the cables and the power supply An external power supply unit is requi...

Page 22: ...arthing of the Industrial PC and thus avoid dangerous touch voltages EMC NOTE Hardware damage due to electromagnetic interference Using the Industrial PC without functional earthing can lead to hardwa...

Page 23: ...ply Cables with a maximum cable cross section of 1 5 mm2 must be used for connecting the power supply To achieve the lowest possible voltage drop on the supply line we recommend connecting the maximum...

Page 24: ...is shut down can lead to data loss Quit the running software and shut down the operating system before switching off the PC When the system is switched off or disconnected from its own power supply t...

Page 25: ...Beckhoff Device Manager to remotely configure the Industrial PC via a web browser More detailed information is available in the Beckhoff Device Manager manual Starting the Beckhoff Device Manager for...

Page 26: ...passwords are an important prerequisite for a secure system Beckhoff supplies the device images with standard user names and standard passwords for the operating system It is imperative that you chang...

Page 27: ...lectric shock Never disconnect the cables from the device during thunderstorms Before you remove the Industrial PC from the control cabinet you must follow the following steps 1 Shut down the operatin...

Page 28: ...14 3 Remove the PC from the control cabinet You have successfully disassembled the PC Fig 14 C6905_Dismantling the control cabinet Disposal of the Industrial PC Be sure to observe the national electro...

Page 29: ...onents and the replacement of other device components contribute to this Repair Only the manufacturer may repair the device If a repair should be necessary contact Beckhoff Service see Chapter 10 1 Se...

Page 30: ...rs UPS battery pack 5 years 2 5 inch hard disk 5 years or after 20 000 operating hours at more than 40 C or after 30 000 operating hours at less than 40 C 3 5 inch hard disk 5 years irrespective of th...

Page 31: ...e For example the following measures can be used Use conductive mats connected to the ground potential as underlays Dissipate possible charges from your own body by touching earthed metal e g control...

Page 32: ...to these components Accessing the battery and CFast You can access the battery and the CFast via the cover on the left hand side To do this remove the four Torx TX10 screws and remove the cover see f...

Page 33: ...ons Nominal voltage Nominal capac ity Diameter Height Weight CR2032 3 0 V 225 mAh 20 0 mm 3 20 mm 3 1 g Chapter 7 2 1 Access to device components 32 shows how to access the battery To change the batte...

Page 34: ...f the BST USB flash drive according to the size of the backup copy of your operating system You can then keep the flash drive as a backup copy For this purpose the BST USB flash drives with SLC flash...

Page 35: ...PC Other cause Check the power supply cable Call Beckhoff Service The Industrial PC does not boot fully Setup settings are incorrect Other cause Check the setup settings Call Beckhoff Service Computer...

Page 36: ...58 Hz 0 035 mm 58 to 500 Hz 0 5 G approx 5 m s2 Shock resistance shock EN 60068 2 27 5 G approx 50 m s2 duration 30 ms EMC interference immunity conforms to EN 61000 6 2 EMC interference emission con...

Page 37: ...PC which can be found on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with...

Page 38: ...to provide adequate protection against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse inter...

Page 39: ...6905_Name plate example 15 Fig 8 UPS function 16 Fig 9 C6905_Mounting plate 18 Fig 10 C6905_Dimensions with standard mounting plate 19 Fig 11 C6905_Control cabinet installation 20 Fig 12 Beckhoff Devi...

Page 40: ...ce pin assignment 11 Table 5 USB interfaces based on device generation 12 Table 6 USB interface pin assignment 12 Table 7 DVI interface pin assignment 13 Table 8 Meaning of the Status LEDs 14 Table 9...

Page 41: ......

Page 42: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com C6905...

Reviews: