Installation Instructions 

 

 

10

 

C3620, C3640 

Installation Instructions 

 

Please also refer to chapter 

General instructions

. 

 
 

Transport and Unpacking 

 

The specified storage conditions must be observed (see chapter 

Technical 

data

). 

 

Transport 

 

Despite the robust design of the unit, the components are sensitive to 
strong vibrations and impacts. During transport, your Industrial PC should 
therefore be protected from excessive mechanical stress. Therefore, 
please use the original packaging. 

 

Warning 

 
Danger of damage to the unit! 
If the device is transported in cold weather or is exposed to extreme 
variations in temperature, make sure that moisture (condensation) does not 
form on or inside the device. 
 
Prior to operation, the unit must be allowed to slowly adjust to room 
temperature. Should condensation occur, a delay time of approximately 12 
hours must be allowed before the unit is switched on. 

 

Unpacking 

 
 

Proceed as follows to unpack the unit: 
 

1. Remove packaging. 
2. Do not discard the original packaging. Keep it for future relocation. 
3. Check the delivery for completeness by comparing it with your order. 
4. Please keep the associated paperwork. It contains important 

information for handling the unit. 

5. Check the contents for visible shipping damage. 
6. If you notice any shipping damage or inconsistencies between the 

contents and your order, you should notify Beckhoff Service. 

 

 

Summary of Contents for C3620

Page 1: ...Installation and Operating instructions for Build in Industrial PCs C3620 C3640 from 0060 Version 4 0 Date 2020 04 24...

Page 2: ......

Page 3: ...dditional plug in cards optional 9 3 Installation Instructions 10 Transport and Unpacking 10 Transport 10 Unpacking 10 Installation of the PC in the control cabinet 11 Earthing measures 11 Power Suppl...

Page 4: ...khoff Service 21 6 Assembly dimensions 22 Industrial PC C3620 22 Industrial PC C3640 23 Mounting Opening 24 7 Appendix 25 Technical data 25 Approvals 25 FCC Federal Communications Commission Radio Fre...

Page 5: ...er EtherCAT TwinSAFE and XFC are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their ow...

Page 6: ...are intended to alert the reader to the associated safety instructions Danger This symbol is intended to highlight risks for the life or health of personnel Warning This symbol is intended to highligh...

Page 7: ...pment that have been switched off must be secured against being switched on again Danger Displays used for the PCs LC display are operated with a voltage of up to 1000 V depending on type For that rea...

Page 8: ...ain legible National regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of...

Page 9: ...ows the front of the PC with TFT display can be opened thus providing access to the drive optional 3 hard disk processor memory and plug in cards An ATX motherboard with seven slots for plug in cards...

Page 10: ...ith seven slots for plug in cards is located behind the removable card holder and the swivel mounted power supply unit The connections of the Industrial PC to the outside are located on top of the hou...

Page 11: ...ctors X112 X113 allow the PC to be connected to a 10 100 1000BASE T Local Area Network LAN DVI D Digital Visual Interface DVI out The DVI connectors X114 X115 are used for transferring the video signa...

Page 12: ...eme variations in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condens...

Page 13: ...not be exposed to direct sunlight When the unit is in its mounting position the ventilation openings must not be obstructed Warning Extreme environmental conditions should be avoided as far as possibl...

Page 14: ...ge CSA 300 V Current EN A 12 A Current CSA A 15 A Length of stripped conductor 8 to 9 mm Power Supply Configuration Supplied mains power unit The Industrial PCs is either fitted with a 100 240 VAC 50...

Page 15: ...signments on the top of the female plug connector The minimum permitted conductive cross section is 1 5 mm fused for 10 A AWG 16 Industrial PCs with 100 240 VAC 50 60 Hz power supply unit Pin assignme...

Page 16: ...mm Minimum conductor cross section AWG 16 Rated voltage EN 250 V Rated voltage CSA 300 V Current EN 16 A Current CSA 15 A Length of stripped conductor 8 to 9 mm Fitting the connector to the cable The...

Page 17: ...ng to the rules The PC_ON signal is inverted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user the PC can be booted in the familiar way by connecting...

Page 18: ...diagram external switch and power supply Wiring diagram Wiring according to the wiring diagram the circuit of PC_ON and Power Status is symbolical Connection of the Battery Pack and UPS Output only i...

Page 19: ...ustrial PC and to the devices that are to be connected Connect all data transfer cables if present to the appropriate plug in receptacles of the data telecommunication networks Reconnect all devices t...

Page 20: ...writing a file to the hard disk the file will be destroyed Control software typically writes something to the hard disk every few seconds so that the probability of causing damage by switching off whi...

Page 21: ...losion Replace battery only with the identical type or an alternative type recommended by the manufacturer Notice correct polarity Danger Handling of Lithium Batteries Lithium Batteries should not be...

Page 22: ...al Setup settings are incorrect Other cause Remove CD and press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of th...

Page 23: ...lshorstweg 20 D 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support offers you comprehensive technical assistance helping you no only with...

Page 24: ...ly dimensions 22 C3620 C3640 Assembly dimensions Industrial PC C3620 Warning The assembly of the unit must take place with the orientation diagrammed here All dimensions in mm front view left view rea...

Page 25: ...Assembly dimensions C3620 C3640 23 Industrial PC C3640 Warning The assembly of the unit must take place with the orientation diagrammed here All dimensions in mm front view left view rear view...

Page 26: ...Assembly dimensions 24 C3620 C3640 Mounting Opening A mounting opening according to the following diagram is required Mounting opening for C3620 Mounting opening for C3640...

Page 27: ...resistance according to EN 61000 6 2 Emitted resistance according to EN 61000 6 4 Transport and storage The same values for atmospheric humidity and shock resistance are to be observed during transpo...

Reviews: