Product overview
32
───
Version: 1.1
AMP8000 and AMP8500
3.7
Ordering options
Ordering options are defined via the type key and must be ordered
separately. The listed components cannot be retrofitted.
3.7.1
Drive-integrated safety
technology
The distributed servo drives are optionally available with integrated
safety functions . These conform to IEC 61800-5-2 and fulfill the fol-
lowing safety standards:
• EN ISO 13849-1:2015, up to Cat 4, PL e
• EN 61508:2010, up to SIL 3
• EN 62061:2005 + A1:2013/A2:2015 up to SILCL3
Communication takes place via the Safety over EtherCAT (FSoE)
protocol according to IEC 61784-3-12.
Information on commissioning and device replacement
For commissioning and device replacement, follow the instructions
in the operating manual AMP8911 – TwinSAFE card for the
AMP8000 distributed servo drive.
Order identifier
Safety functions
AMP80xx-xx
1
x
AMP80xx-xx
2
x
Stop functions
STO
SS1
Safe torque off
Safe stop 1
AMP80xx-xx
3
0
AMP80xx-xx
4
0
Stop functions
STO
SOS
SS1
SS2
Safe torque off
Safe operating stop
Safe stop 1
Safe stop 2
Speed functions
SLS
SSM
SSR
SMS
Safely-limited speed
Safe speed monitor
Safe speed range
Safe maximum speed
Position functions
SLP
SCA
SLI
Safely-limited position
Safe cam
Safely-limited increment
Acceleration functions
SAR
SMA
Safe acceleration range
Safe maximum acceleration
Direction of rotation functions
SDIp
SDIn
Safe direction positive
Safe direction negative
Summary of Contents for AMP8000
Page 1: ...Operating instructions EN AMP8000 and AMP8500 Distributed servo drives 11 15 2022 Version 1 1 ...
Page 2: ......
Page 43: ...Technical data Version 1 1 43 AMP8000 and AMP8500 4 3 1 2AMP8620 2005 0100 4 3 1 2 ...
Page 44: ...Technical data 44 Version 1 1 AMP8000 and AMP8500 4 3 1 3AMP8620 2005 0200 4 3 1 3 ...
Page 47: ...Technical data Version 1 1 47 AMP8000 and AMP8500 4 5 1 2AX8832 0000 0000 4 5 1 2 ...
Page 108: ......