Spray Head:
Snaps on the fountain body - has 19 streams of water - use flow
control to adjust height/size of spray - lower the spray height during windy condi-
tions for better control of the spray.
Bubbler:
Inserts into the fountain body until the ribs bottom out - provides a tube of water
mixed with air - use flow control to adjust height/size of spray - great for hot months when fish
need extra oxygen due to increased water temperature.
Waterbell:
Insert into fountain body until it bottoms out then pull the waterbell
up about 1/4” - moving waterbell deeper into fountain will make spray thinner- ad-
just the thickness of the waterbell spray by moving the water bell up and down in
the fountain body - adjust the size/diameter of spray with the flow control - water-
bell spray may be affected by windy conditions, adjust as necessary.
NOZZLE ADAPTOR INSTRUCTIONS:
ASSEMBLY AND OPERATION INSTRUCTIONS:
DISCHARGE ADAPTORS:
Parts (7) & (8) Easily thread onto
the existing external threads (1/4” & 1/2” npt pipe threads) on the
pump volute discharge.
UNIVERSAL FOUNTAIN KIT
Extension tubes attach here
Secondary accessory/water
feature with 3/8”, 1/2” or
3/4” diameter vinyl hose
connect here.
This setup shows both of the valves in the
full-flow (open) position
Rotate Valve Insert clockwise,
as shown, to restrict flow to
the accessories, but maintain
flow through the fountain.
Rotate both the Valve Body and the
Valve Insert 90° clockwise to shut off
flow to both the fountain and the
accessories.
Rotate the Valve Body clockwise,
as shown, to restrict flow to the
fountain, but maintain flow through
the accessories.
A
A
C
B
C
1.
VALVE OPTION:
You can change your Two-Way Valve into a One-Way Valve using the il-
lustration below and by following step 2. If you do not plan to run a secondary water feature
you can simplify the use of your valve by making it a One-Way Valve. In the event you choose
to add a secondary feature later you can always reinstall the Valve Body (B) by reversing the
procedure in Step 2.
CHANGING THE TWO-WAY VALVE INTO A ONE-WAY VALVE:
2.
VALVE CONVERSION:
To convert the Two-Way
Valve into a One-Way Valve remove the Valve Body
(B) from the Fountain / Extension Tube Adaptor (A)
it simply snaps out with a twist and pull, then us-
ing a pair of pliers to grip the Valve Insert control
(C) and pull it out of the Valve Body (B). Insert the
Valve Insert Control (C) into the Extension Tube
Adaptor (A), push it in until it snaps into place and
rotates freely.
TWO-WAY VALVE OPERATION INSTRUCTION:
HAVING TROUBLE?
NEED REPLACEMENT PARTS?
CONTACT CUSTOMER SERVICE
AT 1-866-466-4319
KEY
DESCRIPTION
PART #
QTY
1
FOUNTAIN
BODY
078-
110112
1
2
BUBBLER
078-
110113
1
3
WATERBELL
078-
110111
1
4 SPRAY
HEAD
078-
110253
1
5
EXTENSION
TUBE
078-
110025
2
6 2-WAY FLOW
CONTROL VALVE
078-
110154
1
7
THREAD ON
ADAPTOR 1/4” NPT
078-
110117
1
8 THREAD ON
ADAPTOR 1/2” NPT
078-
110118
1
6
8
5
5
1
2
3
4
7
92339 rev01
ATTENTION CUSTOMER: STATEMENT OF LIMITED WARRANTY
Beckett warrants to the original purchaser only, the “UNIVERSAL FOUNTAIN KIT” against defects in material and workmanship as follows:
1) Beckett warrants to the original purchaser, the “UNIVERSAL FOUNTAIN KIT” against defects in material and workmanship for 2 years from the date of
purchase.
2) Original Purchaser must retain proof of such purchase in the form of a store sales receipt and must produce such upon request by customer service rep-
resentative at 1-866-466-4319. Do not return product to place of purchase; contact Beckett customer service at 1-866-466-4319 and a knowledgeable
customer service representative will assist you in resolving the problem and arrange replacement of the defective parts as needed.
3) If the product is found to have been consumer damaged or abused, it is not covered by the limited warranty. If this is the case, you will be advised of the
cost of replacement part(s), or the need to return damaged part(s) for warranty replacement.
(PUMPS NOT INCLUDED)
Should you encounter any problems or need replacement parts, contact the Customer Service Representative/Parts Department at
1-866-466-4319 from 8 AM to 5 PM Mon. thru Fri. EST. Extended operating days and hours during peak season requirements.
Molded ribs are
easily self tapped
using existing
threaded
volute outlet.
NOTE: You must
tighten until the
threads bottom
out in adaptor.
After carefully reading all pump safety info and instructions and being sure pump is unplugged, begin assembling your Universal Fountain Kit to your
pump as shown below. Install the two-way flow control valve, extension tubes and fountain body. These connect using a taper fit and only need to be
pressed together. Next choose the fountain nozzle adapter you would like to use and install/adjust as per the instructions below under nozzle adaptor
instructions. If you are connecting a secondary accessory/water feature at this time you will need to select and/or
install the proper vinyl hose adaptor at the two-way flow control valve. Connect the hose after installing your
pump in the pond. Adjust flow as per the instructions below under two-way valve instructions. If you are not
installing a secondary feature at this time, you need to shut-off this part of the flow control valve as per
the flow control valve instructions below.