background image

GeniSys

 

24V

Model 7559

Advanced 24 Vdc Burner Control

Description / Applications

The Beckett GeniSys

TM

 24V Advanced Burner Control is a 

24 Vdc primary safety control for oil burners used in special 
applications including, but not limited to, water heaters, 
pressure washers, crack sealers and portable heaters having 

fi

 ring rates less than 5.5 GPH.  The GeniSys

TM

 24V is used 

with a suitable cad cell 

fl

 ame sensor to control the oil burner 

motor, igniter, and optional solenoid valve.  It has 24 volt enable 
input compatible with mechanical and high limit switches.  It 
can provide interrupted or intermittent duty ignition, and it has 
a 15 second lockout time on 

fl

 ame failure.   

PARTS & ACCESSORIES

Summary of Contents for GeniSys 24V 7559

Page 1: ...water heaters pressure washers crack sealers and portable heaters having firing rates less than 5 5 GPH The GeniSysTM 24V is used with a suitable cad cell flame sensor to control the oil burner motor...

Page 2: ...GPH CAUTION A low or erratic power supply could result in impaired burner operation severe delayed ignition or an explosion inside the heat exchanger resulting in a burn and or asphyxiation hazard Mai...

Page 3: ...ment Skilled in the adjustment of oil burners using combustion test instruments The installation must strictly comply with all applicable codes authorities having jurisdiction and the latest revision...

Page 4: ...know the control SK10048 24V POWER MAIN ALARM VALVE GND VLV IGNITER GND IGN MOTOR GND MTR ENABLE CAD CELL ON OFF RESET HIGH LIMIT MOTOR IGNITER THERMOSTAT CAD CELL RED WIRE BLACK WIRE OIL VALVE Cad C...

Page 5: ...remove the cad cell jumper Simulate Flame Failure and Ignition Failure Refer to the steps for Starting the System and have the system call for heat After flame is established and the burner igniter t...

Page 6: ...hed the igniter remains on for 10 additional seconds to ensure flame stability Run The flame is sustained until the call for heat is satisfied The control then switches to Motor Off Delay if applicabl...

Page 7: ...oil and oil vapor before starting or resetting the burner y y y y Failure to bleed the pump properly could result in unstable combustion hot gas puff back and heavy smoke Hot Gas Puff Back Heavy Smoke...

Page 8: ...y of warranty form 61545 please choose one of the following options Visit our website at www beckettcorp com warranty Email your request to rwb customer service beckettcorp com Write to R W Beckett Co...

Reviews: