GB
DE
23
The company BeckerAntriebe GmbH hereby declares that the light sensor,
radio controlled, Centronic SensorControl SC431 in conformity with the basic
requirements and other relevant provisions of Directive R&TTE 1999/5/EC.
For use in the following countries: EU, CH
Subject to technical changes without notice.
What to do if ...?
General conformity declaration
Problem
Cause
Remedy
Drive is not functioning.
Control light remains
OFF
1. Battery is discharged.
2. Battery is inserted
incorrectly.
1. Replace battery.
2. Insert battery correctly.
Drive is not functioning.
Control light is lit up.
1. Receiver is out of the
radio operating range.
2. The light sensor, radio
controlled, (SC431) is
not programmed in the
receiver
1. Reduce distance to
receiver.
2. Programme the light
sensor, radio controlled,
(SC431)
Control light is fl ashing
permanently.
TEST mode is active
Deactivate setting mode
Control light is fl ashing Battery power is low
Replace battery
Control light is fl ashing
permanently
Encoding switches SUN-
LIGHT and TWILIGHT are
both activated in TEST
mode.
Check operating modes.
Roller shutter does
not move down during
sunlight hours.
1. The light sensor, radio
controlled, (SC431) is set
to manual mode.
2. Sun threshold value is
not exceeded
1. Press the MAN/AUTO
button repeatedly until
the control light lights up
green.
2. Adjust sun threshold
value.
The light sensor, radio
controlled, (SC431)
does not execute any
automatic control
commands.
The light sensor, radio
controlled, (SC431) is set
to manual mode.
Press the MAN/AUTO
button repeatedly until
the control light lights up
green.
The light sensor, radio
controlled, (SC431)
falls off the pane.
Insuffi cient adhesiveness. Clean the pane carefully.