Becker R12/17C Assembly And Operating Instructions Manual Download Page 1

R12/17C...R40/17C

Version: PROF+A2

 

 

en

 

Assembly and Operating Instructions

 

 

Roller shutter drive with integrated radio receiver

915.3 Mhz

 

Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.

 

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

 

Summary of Contents for R12/17C

Page 1: ...tter drive with integrated radio receiver 915 3 Mhz Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Ant...

Page 2: ...onfirming the drive 11 First operation 12 Programming the master transmitter 13 Checking that the running direction is correct 13 Intelligent installation management 13 Setting the limit positions 14...

Page 3: ...ronic system with stop systems Obstacle detection even when using anti lifting devices axle shaft devices Secure anti lifting device Slight pressure applied to the roller shutter curtain makes it diff...

Page 4: ...g in the limit position O with sensitive obstacle detection SMI Standard Motor Interface with R with automatic detection of anti lifting devices with S higher closing force for cassette awnings Softwa...

Page 5: ...rty damage and personal injury Please keep these instructions in a safe place Caution Important safety instructions for the user Failure to observe these instructions can lead to serious injuries All...

Page 6: ...proved by us are prohibited We do not accept liability for dam ages or injury arising from such actions Before installation shut down all lines and control devices that are not essential for operation...

Page 7: ...ety of the users and others since these actions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or...

Page 8: ...onnecting cable must be disconnected On drives with a diameter 45 or 58 insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug f...

Page 9: ...ops in the guide tracks Calculate the space required at the side M by measuring the drive head and wall bracket The clear dimension of the box X minus the space required at the side M and idler G give...

Page 10: ...x 12 screw 3 with appropriate washer 2 and suitable screw retainer Threaded hole 4 Securing the drive against axial displacement 10 mm In order to secure the drive against axial displacement we recomm...

Page 11: ...into the tube to achieve a form fit Ensure that the thrust ring and drive adapter are secure in the tube Mount the assembled unit comprising barrel tubular drive and idler on the box and secure the dr...

Page 12: ...programming Readying the tubular drive for programming by switching on the power Switch on the power The tubular drive is ready to programme for 3 minutes Note If several tubular drives are to be con...

Page 13: ...n Direction switch is OK If the shading solution runs in the wrong direction the running direction must be switched Proceed as follows Switch the direction switch 1 to the opposite position The shutte...

Page 14: ...stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times Upper stop to lower stop Open to the permanent upper stop The tubular dri...

Page 15: ...nge of travel Attention When both or individual limit positions are deleted all the other set functions intermediate position I inter mediate position II upper anti freeze mechanism obstacle detection...

Page 16: ...ions Each travel button can be assigned one intermediate position Both limit positions must be set be fore the intermediate position is set When both or individual limit positions are deleted both int...

Page 17: ...be deleted It can only be overwritten see Programming the master transmitter 13 Press the programming button on the master transmitter for 3 seconds The tubular drive makes a click sound to confirm N...

Page 18: ...to the outside position N 1 2 1 2 4 3 4 230V AC 50 Hz L1 PE Switch off the tubular drive power for 5 seconds then switch it back on The tubular drive is ready to programme for 3 minutes 1 blue 3 blac...

Page 19: ...he shading solution to the upper limit position Press the programming button on the master transmitter for approx 3 seconds The tubular drive makes a click sound to confirm Then re press the programmi...

Page 20: ...UP buttons for ap prox 3 seconds The tubular drive clicks 3 times to confirm Programming the run times Note This function is only available with MemoControl transmitters from the Becker Centronic ran...

Page 21: ...regulations on recy cling or disposal for this product in your country The packaging material must be disposed of properly Maintenance These drives are maintenance free Technical data dia 45 Type R12...

Page 22: ...ction then continue in the desired di rection Tubular drive is overloaded Use a higher torque tubular drive Switching times cannot be set on tubular drive Programmed transmitter has no manual auto sli...

Page 23: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 23...

Page 24: ...Declaration of conformity 24...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...2010 300 570 0a 06 03 2013...

Reviews: