background image

 

Jul 2011, V 1.0 

7

 

       Installation Guide E100M 

 

       

 

          

BECCA HEATER SYSTEMS 

(Optional) 

“Heater5” General Purpose Heater (outside mix room) 

“HeaterEXP” Cls I Div 1- Heat on Demand (Inside or outside of mix room 

                

Instructions for set-up and use 

 

™

 

Fill with 5 gal. Distilled Water and one bottle of BECCA WaterWave Additive (well 
shaken) - - OR - - 5 gal of Paint Co. supplied Waterborne Paint Gun Cleaning 
Solution & one bottle of BECCA WaterWave Additive (well shaken) 
 

™

 

Program 7 day timer (supplied by BECCA): 
 

1.  For Heater5 -  turn “ON” 2 hours before shop opens - - and turn “OFF” at 

typical shop closing time. (Monday thru Friday or Monday thru Saturday) 

2.  For HeaterEXP - turn when shop opens - - and turn “OFF” at typical shop 

closing time. (Monday thru Friday or Monday thru Saturday) 

 

™

 

Plug in timer to electrical outlet - - plug in heater to timer 

1.  Note: When HeaterEXP is located in Mix room the connection can be any 

of the following: 

1.  Exp Cable supplied can be run through the wall and connected 

outside the mix room 

2.  Exp cable minus the plug can be connected inside the mix room to 

an Exp switch or timer (neither are supplied) 

 
 

Warning! 

 

ƒ

 

Evaporation will reduce fluid level - - Check fluid daily and replace as needed. 
DO NOT ALLOW FLUID LEVEL TO DROP BELOW HALF-FULL! 
 

ƒ

 

The purpose of the BECCA nylon pail liners (part #823203-6) is to protect the 
metal container from rusting-out and leaking. DO NOT USE THE HEATER 
WITHOUT A PAIL LINER!

 

 
 
 

Summary of Contents for E100M

Page 1: ...INSTALLATION GUIDE E100M Waterborne Spray Gun Cleaner Featuring Clarifier Recycling System Technical Assistance call 800 655 5649...

Page 2: ...signs of transport damage If damage has occurred contact the shipping company and BECCA Inc immediately Step 2 Begin by removing the staples attaching the box to the skid Carefully remove your Spray...

Page 3: ...o clip in center of the wash basin b Place the magnet with hook on the side of the unit leave white cover on the magnet c Attach the POWERPISTOL to the magnet hook d Place blue lines with QD s into re...

Page 4: ...ariety of applications this part is not supplied by BECCA Connect the shop air to the ball valve with the Ball valve in the Off position Step 5 Check large white drain hose to be sure is attached thro...

Page 5: ...r Wave additive Step 7 Turn on ball valve to apply air to the system and adjust all air and fluid flow levels You are ready to use the BECCA E100M Spray Gun Cleaner Keep the cover over the cleaning ar...

Page 6: ...With the air still connected trigger the gun to expel the solution and blow off the outer gun and the fluid passageway through the Fluid Nipple 9 Blow off the air cap and reconnect it to the gun 9 Wip...

Page 7: ...nday thru Saturday 2 For HeaterEXP turn when shop opens and turn OFF at typical shop closing time Monday thru Friday or Monday thru Saturday Plug in timer to electrical outlet plug in heater to timer...

Page 8: ...is is completed and you receive a copy of the Certified Start up document For more information prices or technical assistance contact your local BECCA distributor or call fax our BECCA Care Numbers 20...

Reviews: