Cleaning and maintenance 

 

 

 

5.7.2

 

Starter 

 

Replace faulty starters immediately. 

  

You can recognize a faulty starter by the blackened ends of the lamps or 
when the lamps can no longer be started. 
Operating a lamp with a faulty starter significantly shortens its service life. The 
lamp loses power and may begin to flicker under certain circumstances. 
The starters are located in either one of the two lamp sockets or are visible 
when the lamps are removed.  

  

 

 

 

Turn 90° and carefully remove from the socket. 

  

  

5.8

 

Clean or replace lamps in the door 

 WARNING! 

 

Acrylic panels may be damaged! 

Residue

 on the panels

, combined with the heat generated by

 

the lamps can 

result in long term damage to panels. 

 

Clean throughly between each use.

 

  

 

  

 

 Door 

handle: 

  

 

Remove the screws and remove door handle. 

  

  

 

  

 

 Acrylic 

glass 

panel: 

  

 

Remove the screws. 

 

Remove the acrylic panel and carefully lay it aside. 

  

  

 

  

 

0

2

/201

2

 

             

Revision 7                 0071106701

                                                                     Operating Instructions - 3

5

Summary of Contents for CVT 42 (COL30L)

Page 1: ...OPERATING INSTRUCTIONS BEAUTY ANGEL E N E R G Y...

Page 2: ......

Page 3: ...and local regulations If you have any questions regarding lamp replacement procedures proper use etc please contact the manufacturer directly at 1 800 643 0086 HFDXVH DOO SK VLFDO DFWLYLW FDQ EH VWUH...

Page 4: ...these instructions can result in serious injury and death can result in damage to the device and the environment Read these instructions carefully before putting this device into operation Please obs...

Page 5: ...10 2 8 Operation and maintenance 10 2 9 Decommissioning 11 2 10 Storage 11 2 10 1 Environmental regulations disposal of lamps and batteries 11 2 11 Export 11 2 12 MP3 music optional 12 2 13 Instructio...

Page 6: ...the surfaces 30 5 3 3 Lamps 30 5 4 Cleaning plan 31 5 5 Maintenance 32 5 5 1 Acrylic panel 32 5 6 Maintenance plan 33 5 7 Instructions for replacing the lamps 34 5 7 1 Beauty Angel lamps 34 5 7 2 Star...

Page 7: ...onal Actual results will vary according to skin type usage genetic influences diet exercise lifestyle etc There is no guarantee of results THIS DEVICE EMITS NO UV LIGHT However prior to use please use...

Page 8: ...e of a direct danger to body and life DANGER Type and source of hazard This safety notice warns of dangers to body and life which are caused by electricity WARNING Type and source of hazard This safet...

Page 9: ...and who have been informed of the dangers involved VibraShape Function The vibration base may also be used during the light application The vibra tion base is used for muscle stimulation of healthy pe...

Page 10: ...misuse safety instructions in the Operation chapter operating instructions cleaning and maintenance instructions Please make the instructions and additional information from the manu facturer are ava...

Page 11: ...ed solely for use by the manufacturer s service personnel or by qualified specialists authorized by the manufacturer 2 6 2 Ventilation WARNING Risk of overheating due to air flow problems Operating fa...

Page 12: ...ity company This can for example interfere with the function of night storage heaters If faults occur due to the operation of the devices then the operator is re sponsible for the installation of an a...

Page 13: ...municipal waste regulations Please retain proof of proper disposal of lamps and batteries Your local regulatory agency can assist you with the disposal of lamps and batteries Report the number of lamp...

Page 14: ...me to prove your granting of stage rights by pres entation of the appropriate stage rights certificate when requested by a repre sentative or another controlling body of the responsible organization A...

Page 15: ...existing warranty with regard to any claims that the customer might have in accordance with the contract of purchase 2 16 Warranty and liability exclusions Warranty and liability claims for personal...

Page 16: ...llen key Connecting lead 3D sound 3 2 Equipment In this description all components and functions are taken into account which must be observed during operation and or when performing maintenance The c...

Page 17: ...Angel lamps 5 Control panel headphone connection 6 Handles 7 Loudspeaker optional 8 Fans body cooling 9 Interior lighting LED 10 Door handle 11 Accent lighting 12 Exhaust air body cooling 13 Exhaust...

Page 18: ...tem with Voice Guide 7 1 Headphone connection 7 2 MP3 connection 7 3 Sound Box 7 4 Subwoofer 7 5 Loudspeakers MP3 cable not pictured 3 5 Function description See page 25 for information on control and...

Page 19: ...h program and its benefits Duration 10 Minutes 10 Minutes 10 Minutes 10 Minutes ers quency quency Description Benefit Wellness low intensity Loosens and relaxes muscles improves flexibility and en han...

Page 20: ...inflammatory agents antifungal agents or St Johns wort Seek medical advice before use if in doubt A light treatment is not recommended in the following circumstances If you have utilized an oxygen fa...

Page 21: ...with their doctor Cardiovascular diseases Hip and knee implants Severe diabetes Severe migraine attacks Tumors Gallstones or kidney stones Acute thrombosis Acute inflammation of the muscular skeletal...

Page 22: ...diabetes Diabetics should always have dextrose and prescribed medications readily available The side effects of nausea vertigo drop in blood pressure and skin irritations are generally harmless Older...

Page 23: ...7 Week 2 3 8 Week 2 3 9 Week 2 3 10 Week 2 3 11 Week 3 12 Week 3 After treatment 1 2 x per week 4 3 Application tips Beauty Angel device Stand up straight and in the center of the device during the ap...

Page 24: ...session The lamps will remain illuminated for the entire 12 minute session Voice guide prompts will inform you at the start and end of the vibrashape session Place your feet on the footmarks 1 Bend k...

Page 25: ...arrow button 3 Plus button 4 Audio system icon 5 Music icon 6 VibraShape icon 7 Display Functions 8 Body cooling icon 9 Volume icon 10 Voice Guide icon 11 INFO icon 12 Right navigation arrow button 1...

Page 26: ...ge setting The LED indicator for the available functions and the navigation ring are illu minated in default mode after starting up the device After selecting a function the respective LED indicator a...

Page 27: ...switched off START STOP also switches off the lamps Program 1 Program 2 Program 3 Program 4 3 Body cooling Body cooling control 4 Voice Guide Switch VoiceGuide off Switch VoiceGuide on Voice Guide pro...

Page 28: ...rnally connected systems e g CD player Select channel maximum Refer to Presettings Guide on Operating Instructions CD MP3 player 8 Accent lighting run ning time Refer to Presettings Guide on Operating...

Page 29: ...2 x 3 5 mm stereo jack plug 2 MP3 player see the documentation from the manufacturer of the MP3 player Connect Plug the MP3 cable stereo jack plug into the Audio system Plug the MP3 cable into the MP...

Page 30: ...trained specialists If work is to be performed on the devices they must be de energized That means that all live cables must be switched off Switching off the device alone is insufficient as certain...

Page 31: ...GER Infections can be spread by skin contact All objects device parts which can come into contact with the user during the application must be disinfected after every application Handles and control p...

Page 32: ...cohol or other liquids containing alcohol should never be used for cleaning 02756 0 Plastic surfaces For cleaning the remaining painted and unpainted plastic surfaces it is best to simply use warm wat...

Page 33: ...mat Silicone X Cleaning and disinfection 28 3 Control panel X Cleaning and disinfection 28 4 5 Handle X Cleaning and disinfection 28 Protective goggles X Cleaning and disinfection 28 MP3 cable X Clean...

Page 34: ...specified maintenance schedule and the regular maintenance are absolutely necessary The current operating hours of maintenance parts can be viewed in service mode The device must be subjected to regu...

Page 35: ...ration and may not be operated any longer Any liability for damage or injury proven to be the result of the use of non genuine spare parts is excluded Component Interval 1000 h 1500 h 3000 h a Lamps d...

Page 36: ...l lamps Replace faulty lamps immediately Always replace the entire set of lamps after the specified operating time Turn 90 and carefully remove from the socket 12231 0 Push the pins vertically into th...

Page 37: ...are located in either one of the two lamp sockets or are visible when the lamps are removed Turn 90 and carefully remove from the socket 5 8 Clean or replace lamps in the door WARNING Acrylic panels m...

Page 38: ...leaning and maintenance Upper lamp cover Loosen screws 3 4 mm Take off the lamp cover Replace the lamps See page 34 Replace the starter See page 35 The assembly is the same process in reverse order 36...

Page 39: ...removing it 3 x 3 x 10987 1 First remove the left acrylic panel Remove the screws Remove the acrylic panel and carefully lay it aside Upper lamp cover Loosen screws 3 4 mm Take off the lamp cover Rep...

Page 40: ...l the panel past the back of the cockpit control and remove to the left Upper lamp cover Loosen screws 3 4 mm Take off the lamp cover Replace the lamps See page 34 Replace the starter See page 35 The...

Page 41: ...n or Replace Ambient Light Remove the screws Remove the lamp cover Replace the lamps See page 34 Replace the starter See page 35 The assembly is the same process in reverse order 02 2012 Revision 7 00...

Page 42: ...vel BEAUTY ANGEL Nominal power consumption 8700 W Rated frequency 60 Hz Rated voltage 230 V Rated fuses 30 Amp 3 Pole or 50 Amp 2 Pole Connecting lead Noise level at 1 m distance from the device 71 6...

Page 43: ...46 0 B 55 in B1 35 in B4 7 in B6 34 in B8 54 in T 51 in T1 55 in T2 73 in T3 34 in H 92 in H1 3 in H2 102 in H3 80 in BK 95 in BK1 20 in BK2 20 in TK 102 in TK1 35 in TK2 12 in 02 2012 Revision 7 0071...

Page 44: ...e is a violation of 21 CFR 1040 FDA 6 3 1 BEAUTY ANGEL Lamp set Number Description Order no a 10 10 Starter Philips BodyTone 120 180W 3031109501 1503321 00 b 10 10 Starter Philips BodyTone 120 180W 30...

Page 45: ...no d 2 2 Low pressure lamps blue Starter S10 58 W 12063 10047 e 1 1 Low pressure lamp blue Starter S10 58 W 12063 10047 6 4 Spare parts and accessories Number Description Order no 15 3 Acrylic panels...

Page 46: ...vice Signs warning of danger areas are attached to the device The signs shown below are examples Ensure that the instruction signs are always clearly rec ognizable and easily legible 9 1 Serial Number...

Page 47: ...Kratz Dr Jonesboro AR 72401 1 800 643 0086 The nameplate is located on the edge of the left panel in the space between it and the adjacent panel It contains important information for identifying the d...