21
N. Install Electrical System
Connect the power source on the data plate of Motor.
Note: 1. For the safety of operators, the power wiring must contact the floor well.
2. Pay attention to the direction of rotations when using 380V, three phase
motors.
Single phase motor
(See Fig. 35)
.
1. Connecting the two power supply lines (fire wire
L
and zero wire
N
) to terminals of
AC contactor marked
L1, L2
respectively.
2. Connecting the two motor wires to terminals of AC contactor marked
T1, T2
.
3. Connecting
A2
of AC contactor to
L2
.
4. Connect the two push button wires to the terminals of AC contactor marked A1,L1.
O. Install Spring and Safety Cover of Cross Beam
(See Fig. 36)
.
3-3
3-8
40
3-2
Fig. 35
Push button
AC contactor
Fig.36
Summary of Contents for 30-4140AE
Page 1: ...FOUR POST LIFT 30 4140S 30 4140SE 30 4140S 30 4140SE 30 4140AE...
Page 11: ...9 D Install Cross Beams See Fig 15 Fig 16 Fig 16 2 Hole towards inside 1 3 3 Fig 15...
Page 25: ...23 IV EXPLODED VIEW Model 30 4140S 30 4140SE 1 2 3 8 18 44 203 32 12 54 55 56 57 45 Fig 38 4...
Page 31: ...29 4 3 POWER UNIT EXPLODED VIEW 071102 Fig 42 220V 60Hz Single Phase...