Beamz 153.272 Instruction Manual Download Page 7

 

FIXTURE CLEANING 

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light 
output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty 
surrounding can cause greater accumulation of dirt on the unit’s optics. 

 

Make sure the area below the installation place is free from unwanted persons during servicing 

 

Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any 
deformation 

 

The mains cables must be in impeccable condition and should be replaced immediately when even a small 
problem is detected 

 

In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned 
monthly. 

 

The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet. 

 

Clean with soft cloth using normal glass cleaning fluid. 

 

Always dry the parts carefully. 

 

Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

  

 

 

 

HOW TO CONTROL THE UNIT 

 

Three ways to operation: 

A.  Master/Slave mode 
B.  Sound active and Auto mode 
C.  DMX controller 

 

MODE 

MENU 

UP - DOWN 

DMX MODE 5CH

 

(ch. 1-512) 

 

     

 

DMX  MODE  6CH

 

(ch. 1-512)

 

 

     

 

AUTO MODE 

(program 1 – 4) 
(speed 1 – 9)) 

      

 

     

 

SOUND MODE 

(program 1 – 4) 
(speed 1 – 9) 

       

 

     

 

 

 

 

 

 

 

 

ATTENTION: We strongly recommend internal cleaning to be carried out by qualified 

worker! 

Summary of Contents for 153.272

Page 1: ...LCP 12UV 12x 3W UV Strobe Ref nr 153 272 INSTRUCTION MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES V1 1 ...

Page 2: ...re the unit with an extra safety chain if the unit is ceiling mount Use a truss system with clamps Make sure nobody stands in the mounting area Mount the effect at least 50cm away from inflammable material and leave at least 1 meter space on every side to ensure sufficient cooling This unit contains high intensity LEDs Do not look into the LED light to prevent damage to your eyes Do not repeatedly...

Page 3: ...ij gebruik en direct na gebruik Om ongevallen in bedrijven te voorkomen moet rekening worden gehouden met de daarvoor geldende richtlijnen en moeten de aanwijzingen waarschuwingen worden gevolgd Zorg voor een extra veiligheidsketting als het apparaat op hoogte wordt gehangen Gebruik een truss systeem met clamps Ga nooit onder het apparaat staan bij ophanging Monteer minimaal 50 cm van brandbare ob...

Page 4: ... Richtlinien beachtet und die Anweisungen Warnungen befolgt werden Wenn das Gerät an der Decke befestigt werden soll muss es mit einer zusätzlichen Sicherheitskette abgesichert werden Benutzen Sie ein Traversen system mit Haken Während der Montage darf sich niemand im Bereich darunter aufhalten Das Gerät muss mindestens 50cm von brennbaren Materialien entfernt angebracht werden Lassen Sie einen Mi...

Page 5: ... en las empresas debe seguir las directrices aplicables y seguir las instrucciones Asegure el aparato con una cadena de seguridad extra si el aparato se monta en un techo Utilice un sistema de truss con ganchos Asegúrese de que nadie permanece en el área de montaje Monte el efecto a una distancia de al menos 50cm de materiales inflamables y deje un espacio de al menos 1 metro a cada lado para perm...

Page 6: ...ration another time The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year The fixture should be installed in the position where persons cannot reach and where persons may walk by or be seated POWERSUPPLY On the label on the backside of the light effect is indicated on this type of power supply must be connected Check tha...

Page 7: ...uld be replaced immediately when even a small problem is detected In order to protect the fixture from overheat the cooling fans if any and ventilation openings should be cleaned monthly The interior of the fixture should be cleaned annually using a vacuum cleaner or air jet Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least ev...

Page 8: ...setup the auto standalone mode Press MENU repeatedly until Ax x shows on the display Use MENU select auto program A1 x A4 x Use UP or DOWN to choose the speed of the program Ax 1 Ax 9 Press ENTER Mode Program Variable Speed A1 Mode Auto Program 1 Speed 1 9 A2 Mode Auto Program 2 Not Flash Speed 1 9 A3 Mode Auto Program 3 Flash Speed 1 9 A4 Mode Auto Program 4 All Bright Flash Speed 1 9 Sound mode ...

Page 9: ...peed 3 000 255 Strobe 4 011 200 Auto mode 201 255 Sound mode 5 000 255 Auto Sound Speed Slow Fast 6 Channels DMX code setting H001 H512 Channel Value Description 1 000 255 LED Effect Group 1 2 000 255 LED Effect Group 2 3 000 255 LED Effect Group 3 4 000 255 LED Effect Group 4 5 000 255 LED Effect Group 5 6 000 255 LED Effect Group 6 TECHNICAL SPECIFICATION Rated voltage AC100 240V 50 60Hz Rated p...

Page 10: ...10 ...

Page 11: ...cription LCP12UV 12x 3W LEDs UV Strobe Regulatory Requirement EN 60598 1 2008 A11 2009 EN 60598 2 17 1989 A2 1991 EN 55015 2013 EN 61547 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 EN 62471 2008 EN 62493 2010 The product meets the requirements stated in Directives 2006 95 and 2004 108 EC and conforms to the above mentioned Declarations ALMELO 19 05 2014 Signed P Feldman ...

Page 12: ...www tronios com Copyright 2014 by TRONIOS the Netherlands ...