5
DISPLAY
The control board offer several features: you can simple set the starting address,
run the pre-programmed program or make a reset. The main menu is accessed
by pressing the
Mode
-button, browse through the submenu by pressing
Up
or
Down
.
Press the
Enter
-button in order to select the desired menu.
You can change the selection by pressing
Up
or
Down
. Confirm every selection
by pressing the
Enter
-button.
You can leave every mode by pressing the
Mode
-button. The functions provided
are described later in this manual.
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the
first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected.
5-pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-512 data cables for DATA transmission in place of 3-pin. 5-pin DMX fixtures may be
implemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used.
The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out) 5-Pin XLR Male (In)
Ground/Shield
Pin 1
Pin 1
Data Compliment (- signal)
Pin 2
Pin 2
Data True (+ signal)
Pin 3
Pin 3
Not Used
Pin 4 – Do Not Use
Not Used
Pin 5 – Do Not Use
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+) into a 3-pin
XLR connector and plug this into the DMX output of the last fixture in the chain.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit’s optics.
Make sure the area below the installation place is free from unwanted persons during servicing.
Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation.
The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected.
In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION:
We strongly recommend internal cleaning to be carried out by qualified worker!