32
Specification Summary
Electrical & Environmental
Specifications - IsatDock MARINE
Average Power
Consumption Current
@ 12v
Average
Watts
Power w/o IsatPhone
Pro
130mA
1.6W
S Charging
360mA
4.3W
Tr Charging
875mA
10.5W
Sleep Mode
5mA
60mW
Peak Current
3.5A
42W
Physical Specifications
Dimensions
270 x 189 x 101
(mm)
10.6 x 7.4 x 4
(inches)
Weight - dock
1665g
3.67lbs
Total Kit Weight
2715g
5.99lbs
Environment Specifications
Operating Range
-30
o
C to +70
o
C
-22
o
F to +158
o
Storage
-35
o
C to +85
o
C
-31
o
F to +185
o
F
Battery Charging
Temp*
0
o
C to +45
o
C
+32
o
F to 113
o
F
Humidity
<= 75% RH
GPS Module (internal)
Channels
14 tracking, 51 channel acquiring
Update Rate
1Hz
Accuracy
Position 2.5m CEP, Velocity 0.1m/s,
Timing 300ns
Acquisition TTFF
Cold 29sec, Hot 1sec
Sensitivity
-161 dBm
Operational Limits
Altitude 18000m, Velocity 515m/s
Dynamics
4G
I/O Alarm/Alert
Alert Button in-built
Two button press
1 x alarm loop
Bare wire - “Normally closed” loop
IN to OUT
Track
In-built - single key press
Connectors / Interfaces
POTS/RJ11
RJ11/2-wire, 5REN @ 600m, Adjustable
dial, ring, busy tone configured
frequency and adaptive impedance.
Inmarsat Antenna
TNC-Female
GPS Antenna
SMA-Female
10-32V DC
4-way microFit
(AC/DC adaptor, or DC lead)
Privacy Handset Port
RJ9 connector
Configuration /Data
USB Micro
Speakerphone
In-built speaker/microphone
Certifications
Inmarsat
FCC
CE Compliance
Electrical Safety
RoHS
IP54 Rating
Industry Canada
C-Tick
EMC compliance
Accessories
LTO - LeoTRAK-Online - www.leotrak.com
ISD710 - Maritime Active Antenna
ISD715 - Transport Active Antenna (Magnetic)
ISD720 - Transport Active Antenna (Bolt)
ISD700 - Directional/Fixed Passive Antenna
ISD936 - 10m Passive Cable Kit
ISD937 - 20m Passive Cable Kit
ISD932 - 6m SMA/TNC Active Cable Kit
ISD933 - 13m SMA/TNC Active Cable Kit
ISD934 - 18m SMA/TNC Active Cable Kit
ISD935 - 31m Active Cable Kit
RST410 - “Alert Pendant” Kit
RST055 - UPS Battery Pack
Kit Contents
IsatDock MARINE
110-240V AC Plug Pack
Privacy Handset
10-32V DC Power Cable
2m Alert wiring loop
Handset lockiing key
User manual & Quick Start Guide
Wall mounting plate
NOTE:
Specifications are subject to change without notice.
* It is ideal for the ambient temperature to be
approximately 18 degrees below the 45
o
C upper limit for
the handset to charge the battery whilst docked.