Rigging the fixture
Caution!
1. The installations must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures if you have doubts concerning the safety do not install.
3. Unit is to be 24inches away from flammable materials (decoration material)
4. Use high quality installation equipment to hang unit.
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experi-
ence including but not limited to calculating working loads, material being used and periodic safety inspections. If you
lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the projector
has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming. Installation should be
checked at least one time a year by a skilled person.
Rigging the fixture
Caution!
1. The installations must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures if you have doubts concerning the safety do not install.
3. Unit is to be 24inches away from flammable materials (decoration material)
4. Use high quality installation equipment to hang unit.
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experi-
ence including but not limited to calculating working loads, material being used and periodic safety inspections. If you
lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the projector
has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming. Installation should be
checked at least one time a year by a skilled person.
7
No Function
No Function
0-255
0
8
Frost
No Function
0-127
0
Frost (clear to frost)
128-255
9
Focus
Focus
0-255
0
10
Pan
Pan Course
0-255
128
11
Pan Fine
Pan Fine
0-255
128
12
Tilt
Tilt Course
0-255
128
13
Tilt Fine
Tilt Fine
0-255
128
14
Pan & Tilt Speed
Pan & Tilt Speed (Fast to Slow)
0-255
0
No Function
0-26
15
Reset
Lamp Reset
26-76
0
Pan Tilt Reset
]77-127
All Reset
128-255
No Function
0-9
16
Lamp Control
Lamp OFF (hold for 3 seconds)
10-100
0
Lamp ON (hold for 3 seconds)
101-255
10
Summary of Contents for 17R
Page 2: ......