Operational Passive_Alarm mode
This mode is similar to the Operational Active_Alarm mode, except that the beacon is silent until
an event occurs.
Configuration mode
This mode is used for testing and configuration. In this mode the beacon does undirected
connectable advertising. This mode is entered when the Operational mode is connectable and a
(central) client connects. When connected the (central) client can interact with the Configuration
Service in the beacon. The only way to leave the Configuration mode is by uploading and activating
a valid TLV file.
Alarm broadcast
The broadcast in the alarm state of modes Operational Active_Alarm and Operational
Passive_Alarm consists of just one frame type and can be either connectable or non-connectable1.
Behavior on reset
On reset the beacon checks whether valid TLV configuration file is present in flash. If so its
configuration values are used. If no TLV file is present or is erroneous, the beacon uses the default
configuration.
To show which of these is the case the beacon flicks LEDs just after startup:
• Twice green LED when TLV content is used.
• Green LED followed by red LED when TLV configuration is not supported.
• Twice red LED when TLV configuration is supported but TLV data are erroneous.
Product specification
Product usage scenario: