background image

 

Beacon IT001 (TWHBC01 module) User Manual 

 

IT001  is  a  broadcast  protocol  based  on  the  bluetooth  BLE  protocol.  It  is  usually  installed  in  a 

suitable location, and it will broadcast continuously or periodically to its surrounding environment 

 

The IT001 beacon allows to create Bluetooth® Low Energy (Bluetooth LE) 5.0 solutions. Besides 

basic Bluetooth LE advertising functionality via radio transmission, the TWHBC01 beacon allows 

additional functionality thanks to the add-on hardware components: a green and a red LED, a push 

button and an accelerometer with built-in thermometer. Depending on the casing not all hardware 

components may be present or can be used. The accelerometer can be configured for detection 

of specific events. Currently the following events are supported: free fall, single tap, double tap, 

activity/movement and flip-flop. 

There are two aspects concerning the TWHBC01 beacon firmware. 

On  the  one  hand  there  is  a  firmware  implemented  as  a  release  HEX  file  with  functionality  as 

described in this document. A major objective in the implementation is low current consumption 

hence long battery lifetime. There are many parameters that affect the behavior of the firmware. 

The release firmware has default values for these parameters. 

 

Firmware Functionality 

TWHBC01 beacon can be in five modes: 

• Transport & Warehousing 

• Configuration 

• Operational Active 

• Operational Active_Alarm 

• Operational Passive_Alarm 

By Operational mode we refer to the actual mode that is configured and can be either Operational 

Active, Operational Active_Alarm or Operational Passive_Alarm. 

 

Transport & Warehousing mode 

As its name suggests, this mode is meant for the beacon to be silent for a long period and only to 

be woken up when needed. Therefore this mode has no advertising broadcast. 

Wake-up can occur on possible events: 

• Accelerometer event 

• Short press on push button 

On wakeup the beacon goes to the configured Operational mode. 

 

Operational Active mode 

In this mode the beacon does an undirected advertising (broadcast) with frame content defined 

by the configuration parameters. The broadcast can be either connectable or non-connectable. 

When it is connectable, the beacon reverts to Configuration mode on connection by a (central) 

client, where a new configuration can be uploaded. The connectable option should only be used 

for testing purposes. 

Based on configuration settings, the push button and/or accelerometer can be enabled. 

On occurrence of the alarm state, which is triggered by either a long press of the push button or 

on accelerometer event, the beacon stops advertising for a given period (alarm duration timer), 

after which it restarts normal broadcast. 

 

Operational Active_Alarm mode 

This mode is similar to the Operational Active mode, except that during the alarm state the beacon 

broadcasts an alarm frame instead of being silent. 

On occurrence of the alarm state, the beacon starts an undirected alarm broadcast for a given 

period (alarm duration timer), after which it restarts normal broadcast. 

 