                          circulation

 

       

2

                                               

 

                                                                                      Set start of circulation 

                                                     

 

 

                                                     

 

3

     

   

                                                                    Set lasting time for circulation

 

                                                     

 

4

         

 

Finished 
 

 

 

3)

Press

  to set the circulation times; it will show the minimum(5 minutes) on the LCD and this time will 

not flash. It will add 5 minutes by pressing 

  each time.

 It will add 1 hour by pressing

each 

time

The maximum working time is 19hours and 55 minutes.

 When you have completed this procedure continue 

to the next setting. 

 

4)

If  all  settings  have  been  correctly,  set  Press 

  for  confirmation

  ,  the  system  will  quit  this  mode 

automatically(press key 

” to clear settings and exit). 

 

***Notice*** 

 

1 All the setting of Circulation-cleaning must be set on Power OFF status 
2  Circulation  PUMP  and  OZONE  are  not  working  while  setting  the  circulation 

cleaning.

 

 

5

Set preheating (if required)

 

Only  one  pre-heating  setting  is  allowed  each  day  if  required.The  LCD  can  show  clearly  in  the  following 

Summary of Contents for SPA-520

Page 1: ...1 HOT TUB Model SPA 520 OPERATING INSTRUCTION...

Page 2: ...ry Lock Surfing pump 1 On off SET Radio channel read Close view pump 2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set...

Page 3: ...re If there is a problem with the circuit board the controller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and cir...

Page 4: ...cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and t...

Page 5: ...d 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key...

Page 6: ...ee following Fig 7 8 ON OFF Fig 7 Pre heat On 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Conti...

Page 7: ...Press SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 45 5 When everything is set correctly press the to confirm...

Page 8: ...shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turne...

Page 9: ...annel LCD will display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max i...

Page 10: ...off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All water pumps and heating system can not start up However the corresponding signals will f...

Page 11: ...d be supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage syste...

Page 12: ...nge a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 p...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Reviews: