BEA WIZARD II Quick Setup Manual Download Page 2

5

Radar Motion Sensing Field: Width

6

Radar Motion Sensing Field: Depth

3.2’ 6.4’

3.2’

6.4’

3.2’

6.4’

9.6’

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

13.1’

Sensitivity

0 (min) → 9 (max) 

default = 7

0
3
6
9

0

3.2’

6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

15° 30° 45°

30°

45°

15°

Wide Pattern

Narrow Pattern

7

IR Presence Sensing Field / IR Assisted Setup

An Assisted Setup is Required

 after installation and any time after mechanical IR adjustments. With remote unlock, setup (magic wand), 0. Or 

to perform a manual assisted set up; simply momentarily depress the right most push button on the top right of the Wizard. The red & green led 

will alternately flash approximately 16 seconds during set up. Keep area clear of traffic during this process. If the Wizard flashes fast red after 

the assisted setup then an error has occurred. Repeat the assisted setup or see the Wizard II user guide troubleshooting section pages 8-9.

0

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

0

3.2’ 6.4’

3.2’

6.4’

0

3.2’

6.4’

9.6’

Wide Pattern

Narrow Pattern

2nd Radar Antenna

Radar Motion Sensor

F1

Optional Setup Configurations F1

F1 Function

: For a 4 wire connection in lieu of a 6 wire connection - see step 3 for wire connections.

The purpose of selecting safety output redirection using the universal remote (Unlock, F1, 1, Lock, Lock) is to allow the installer two options as 

outlined below. With either option; it is absolutely mandatory to redirect the safety signal to the green & white wires. 

Using the remote control 

follow this sequence: Unlock, F1, 1, Lock, Lock. If this is not done the safety signal will not keep the door(s) open if a person occupies 

the threshold area even if the Wizard II red LED is indicating detection.
Option 1

: To enable the Wizard to function correctly with older non micrprocessed controls. This disables the brown and blue wire function and 

redirects the output of the safety signal to the green and white wires. Both motion and presence will now output on the green (NO) and white 

(COM) wires.

Option 2

:  If the installer wants a 4 wire connection in lieu of the preferred 6 wire connection, simply use the red and black wires for power and 

the green (NO) and white (COM) for a combined output signal of the motion and presence zone.

Automatic Door Control Connections

BEA, Inc. Recommends a 

dedicated transformer to power 

the Wizard II. Contact Technical 

Support if you intend to utilize 

the door control power supply.

ACT

COM

SAF

ACT

COM

SAF

Besam 4000

5 & 7

6

17 & 19

Horton 2160

Blk

Wht

Grn

Besam amd1

2 & 4

6, 11

8 & 9

Hunter

SS

Com

SB

Besam amd2

12 & 13

5, 11

7 & 9

KM

Red

Grn

Yel

Besam uni

2 & 5

1, 4, 10

11 & 12

KM/Rec 5000

2

3

6

Dorma

6

1

2

Stanley Dura

(TB2) 4 & 8

(TB2) 3 & 7

(TB3) 7 & 8

DOM

Brn

Brn

Brn / Wht

Stanley 521

(TB4) 4 & 8

(TB4) 3 & 7

(TB3) 7 & 8

GT1100

Blk

Red

Wht

Tormax tlp/lc

2 & 4

3

Horton 2150

2 & 3

4, 7, 9

6

Tormax tep/xp

2 & 7

3

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc.  If you must wait for the 

following workday to call BEA., leave the door inoperable until satisfactory repairs can be made.   Never sacrifice the safe operation of the automatic door or 

gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week.  For more information, visit www.beasensors.com.

US and Canada:

Canada:

Northeast:

1-866-249-7937

1-866-836-1863

1-866-836-1863

Southeast:

Midwest:

West:

1-800-407-4545

1-888-308-8843

1-888-419-2564

Page 

of 

2           

75.5269.02 

20071011

Optional Setup Configurations IR Immunity

Normal Mode

: This is the normal operation of IR rows. One or both  IR rows are active. See User’s Guide page 6 for more IR curtain options.

Rain Mode

: Is enabled but only triggered to ON when 2 learn cycles are performed within 6 detections. This will enable the outer most IR row to  

perform an instantaneous learn when detection occurs. The inner most curtain will not be affected. This mode will be effective for a 1hr  

countdown timer or power cycle whichever occurs 1st. Rain mode is ineffective if the auto learn time is set to infinite.

Snow Mode

: Is enabled but only triggered to ON when 2 learn cycles are performed within 6 detections. This will also enable the outer most IR  

row to perform an instantaneous learn when detection occurs. In addition it will deploy additional software when unwanted detection occurs  

when the reflectivity of the floor condition is constantly changing. This mode will be effective for a 1hr countdown timer to reduce the IR learn  

capability to 10 seconds. After 1hr or a power cycle the Wizard will return to normal mode. Snow mode is ineffective if the auto learn time is set  

to infinite.

0

0

0

OBSOLETE