BEA VIO-M1 User Manual Download Page 3

VIO-M1

1

1
2
3
4
5

1
2

1
2

1

3

1
2

3

TROUBLESHOOTING

The door remains 
closed. 
The LED is OFF.

The sensor power is off.

Check the wiring and the power supply.

The door does not 
react as expected.

The door closes and 
opens constantly.

Improper output 
configuration on the sensor.

The sensor is disturbed by 
the closing of the door or 
vibrations caused by the 
door motion.

The door opens for 
no apparent reason.

It rains and the sensor 
detects the motion of the 
rain drops.

Change the output configuration setting on 
each sensor connected to the door operator.

Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.

Change the antenna angle.
Decrease the field size.
Increase the immunity filter.

Make sure the detection mode is unidirectional.
Increase the immunity filter.
Use a rain accessory.

In highly reflective 
environments, the sensor 
detects objects outside of its 
detection field.

In airlock vestibules, 
the sensor detects the 
movement of 
the opposite door.

Change the antenna angle.
Increase the immunity filter.

SAFETY INSTRUCTIONS

- Test the good functioning of the installation before leaving the premises.

- The sensor cannot be used for purposes other than its intended use.

-  The manufacturer of the door system incorporating the sensor is responsible for compliance of the system to applicable national and 

international regulations and safety standards.

-  The manufacturer of the sensor cannot be held responsible for injury or damage resulting from incorrect use, installation or 

inappropriate adjustment of the sensor.

-  The installer must read, understand and follow the instructions given in this manual. Improper installation can result in improper 

sensor operation.

- Only trained and qualified personnel may install and setup the sensor. 

- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. 

- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to 

  neon lamps or moving objects.

- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.

Summary of Contents for VIO-M1

Page 1: ...ection Temperature range Dimensions Tilt angles microwave doppler radar 24 150 GHz 20 dBm EIRP 5 mW cm motion 5 cm s measured in sensor axis 12 V to 24 V AC 10 50 60 Hz 12 V to 24 V DC 30 10 2 W relay free of potential change over contact 42 V DC AC peak 1 A resistive 15 W from 1 8 m to 3 m IP54 IEC EN 60529 from 20 C to 55 C 180 mm L x 58 mm H x 50 mm W 15 to 45 vertical 15 to 15 lateral TECHNICA...

Page 2: ...2 2 m FIELD SIZE DIP 1 DETECTION MODE DIP 2 OUTPUT CONFIG DIP 3 PRM MODE DIP 4 IMMUNITY FILTER bidirectional unidirectional NO NC for PRM normal high normal PRM persons with reduced mobility DIP 1 needs to be ON for this function field size max vertical angle 30 2 2 m 2 2 m MOUNTING WIRING COM NO NC 12 24 V DIP SWITCH DOOR CONTROLLER Mount the sensor securely Depending on OUTPUT CONFIGURATION sett...

Page 3: ...ibules the sensor detects the movement of the opposite door Change the antenna angle Increase the immunity filter SAFETY INSTRUCTIONS Test the good functioning of the installation before leaving the premises The sensor cannot be used for purposes other than its intended use The manufacturer of the door system incorporating the sensor is responsible for compliance of the system to applicable nation...

Page 4: ...ginal instructions 42 7808 V3 04 22 BEA hereby declares that the VIO M1 is in conformity with European directives 2014 53 EU RED 2011 65 EU RoHS The complete declaration of conformity is available on our website PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING This product should be disposed of separately from unsorted municipal waste ...