WIRING (cont.)

SET-UP

Six adjustments can be made to the sensor:

LED color+logic:  DIP bank 1 determines LED color (see 
table)

Output Mode switch:  determines Toggle mode or Timer mode

  = Toggle (detection activates the relay and the relay holds until a second detection deactivates 

the relay (recommended for switch applications)

  = Timer (detection activates the relay for 0.5 to 30 seconds; relay will hold as long as detection 

occurs)

LED activity (when illuminated):  

 = animated (movement around track)

 = standard (on, static)

Buzzer sound (when in detection):

 = on

 = off

Hold time potentiometer:  adjust relay hold time from 0.5 to 30 seconds (rotate clockwise to increase)

Sensitivity potentiometer:  adjust detection field from 4 to 24 inches (rotate clockwise to increase)

5

6

2

3

4

DIP1

DIP2

DIP3

DETECTION

NO DETECTION

blue

off

off

blue

blue

blue

green

off

off

green

green

green

blue

green

green

blue

1

RETROFIT APPLICATION

You can retrofit hardwired push plates using the 900 MHZ Touchless Retrofit Transmitter 
(10TD900TR) and Receiver (10RD900):

1. Locate existing 2 wires previously used for the hardwired, mechanical push plate and 

connect to the MS41 terminals marked 12 – 24 VAC/VDC.

2. Wire to the transmitter's power wires (red and black) with the two MS41 power wires.
3. Wire the transmitter's white wire to COM, and green wire to N.O.
4. At the door control, move the 2 wires from the push plate activation circuit to power (refer 

to Technical Specifications for power information).

5. Wire the receiver output to the door control activation circuit and its power wires shown in 

step 3 above.

Summary of Contents for MS41

Page 1: ...adapter bracket 2 Not provided by BEA 6 ROUND TECHNICAL SPECIFICATIONS Technology microwave motion sensor Radiated frequency 24 125 GHz Radiated power density 5 mW cm2 Supply voltage to be operated from SELV compatible power supplies only 12 24 VAC 10 12 24 VDC 30 10 Supply frequency 50 60 Hz Power consumption 1 5W Output relay contact rating max voltage relay contact rating max current Max switch...

Page 2: ...e plate on either the top or bottom Only two snap fittings must be loosened empty N C N O COM 12 24 VAC VDC 12 24 VAC VDC PRECAUTIONS Shut off all power going to header before attempting any wiring procedures Maintain a clean and safe environment when working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when perfo...

Page 3: ...ty potentiometer adjust detection field from 4 to 24 inches rotate clockwise to increase 5 6 2 3 4 DIP1 DIP2 DIP3 DETECTION NO DETECTION blue off off blue blue blue green off off green green green blue green green blue 1 RETROFIT APPLICATION You can retrofit hardwired push plates using the 900 MHZ Touchless Retrofit Transmitter 10TD900TR and Receiver 10RD900 1 Locate existing 2 wires previously us...

Page 4: ...ctivation Wrong output mode Switch output mode to Timer Incorrect wiring connection Check wiring and relay connection BEA Original Instructions PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOR PRINTING FCC APPROVAL This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions this device may not cause harmful interference ...