background image

MS41

75.5996.03 MS41 20210421 

 

Page 1 of 4

Specifications are subject to change without prior notice.

All values measured in specific conditions.

Visit website for 
available languages of 
this document.

MOUNTING BOX COMPATIBILITY

SINGLE-GANG

2 ¾" H × 3 ¼" W × 

15

16

" D

DOUBLE-GANG

4 ½" H × 4 ½" W × 

15

16

" D

6” ROUND

6" H × 6" W × 1" D

SURFACE-MOUNT

10BOX24SGSM
10ABOXSGSMS

10BOXDGSM

10BOX475SQSM

1

10BOX45SQSM

1

10BOX6RNDSM

1

FLUSH-MOUNT

standard, single-gang 

electrical box

2

standard, double-gang 

electrical box

2

10BOX45SQFM

1

standard, single-gang 

electrical box

2

Stainless steel, touchless actuator with 

adjustable range and relay hold time

SINGLE-GANG

ENGLISH

4.5” SQUARE

1.  Must use adapter bracket.

2.  Not provided by BEA.

6” ROUND

TECHNICAL SPECIFICATIONS

Technology:

microwave motion sensor

Radiated frequency:

24.125 GHz

Radiated power density:

< 5 mW/cm

2

Supply voltage:

to be operated from SELV-compatible 

power supplies only

12 – 24 VAC ±10%

12 – 24 VDC +30% / -10%

Supply frequency:

50 – 60 Hz

Power consumption:

< 1.5W

Output

relay contact rating (max. voltage):

relay contact rating (max. current):

Max. switching power:

relay with switch-over contact (voltage-free)

60 VDC / 125 VAC

1A (resistive)

30W DC / 60 VAC

Wire gauge:

26 – 22 AWG

Detection range:

4 – 24” (adjustable)

Detection mode:

motion (bidirectional)

Output hold time:

0.5 – 30 sec

Temperature range:

-4 – 131 °F (-20 – 55 °C)

Weight:

0.34 lbs

IP rating:

IP55

*

Apply silicone to sensor housing base to achieve IP65 (see page 4)

*

Certification:

Electromagnetic compatibility (EMC) according to 2004/108/EC

FCC:  G9B-210161

   IC:  4680A-210161

Summary of Contents for MS41

Page 1: ...adapter bracket 2 Not provided by BEA 6 ROUND TECHNICAL SPECIFICATIONS Technology microwave motion sensor Radiated frequency 24 125 GHz Radiated power density 5 mW cm2 Supply voltage to be operated from SELV compatible power supplies only 12 24 VAC 10 12 24 VDC 30 10 Supply frequency 50 60 Hz Power consumption 1 5W Output relay contact rating max voltage relay contact rating max current Max switch...

Page 2: ...e plate on either the top or bottom Only two snap fittings must be loosened empty N C N O COM 12 24 VAC VDC 12 24 VAC VDC PRECAUTIONS Shut off all power going to header before attempting any wiring procedures Maintain a clean and safe environment when working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when perfo...

Page 3: ...ty potentiometer adjust detection field from 4 to 24 inches rotate clockwise to increase 5 6 2 3 4 DIP1 DIP2 DIP3 DETECTION NO DETECTION blue off off blue blue blue green off off green green green blue green green blue 1 RETROFIT APPLICATION You can retrofit hardwired push plates using the 900 MHZ Touchless Retrofit Transmitter 10TD900TR and Receiver 10RD900 1 Locate existing 2 wires previously us...

Page 4: ...ctivation Wrong output mode Switch output mode to Timer Incorrect wiring connection Check wiring and relay connection BEA Original Instructions PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOR PRINTING FCC APPROVAL This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions this device may not cause harmful interference ...