BEA MINI FLY Quick Start Manual Download Page 2

  

1

MINI FLY

2

Remove the aluminum screws on 
each side of MFCA bracket with  
screwdriver.

Open the front cover, setting and chec-
king the position of dip-switch and poten-
tiometer (take dip-switch&potentiometer 
setting for reference.)

Install the masking lens if needed, 
and get related detection fi eld( 
take detection fi eld setting for 
reference.)

Connecting the cable, and fi x the sen-
sor to MFCA base with 2 black screws 
, notice the mounting direction, and 
make sure the position of wire connec-
tor is facing outside the door(MFCA).

Step 1.

Step 2.

Step 3.

Step 4.

Step 6.

Step 5.

Dip-switch 1

Dip-switch 2

Dip-switch 3

on

Strong interference mode

Passive output(NC)

Hold time:2s

off

Factory mode

Active output(NO)

Hold time:0.5s

54

Working model setting ( Dip-switch 1)

Factory mode: Suit for normal working environment (factory setting).

Strong interference mode: Suit for complex environment with lots of interference source ( this will increase the response time about 10%.)

Stick the template on the ceiling and cut out the hole. 
Clip the sensor on the MFCA with screws. If needed 
to change the factory settings, please follow up the 
following steps (step1-step6):

Protect the sensor periphery before sawing

Mounting template

Ceiling aperture

Þ[””

Þ[””

The sensor must be fi rmly fastened in order to avoiad vibrations.

Mounting tips:

When mounting the MINI FLY, make sure you adjusting the angle 
before tightening the screws.

Always use the aluminum screws to fasten the internal bracket 
and the black screws to fi x the sensor.

After changing the parameter, 
close the front cover, installed the 
bracket, and tighten two screws on 
each side of the bracket after adjust 
the angle .

"+" stands for the detection fi eld 
towards person. MFCA maximum angle 
is +4°.

"-" stands for the detection fi eld 
towards doors. MFCA maximum angle 
is -4°.

MOUNTING & SETTING

DIP-SWITCH SETTING

Outside the door

MINI FLY

3

The above drawings show the typical sensing fi eld dimensions.
You can move the sensor’s detcion fi eld through change the angle of MFCA bracket ( -4° to +4°) .

Relay confi gurations

Active mode

Passive mode

DETECTION

NO DETECTION

Relay model setting (Dip-switch 2)

Adjustment the sensitivity with potentiometer

LED:

Profi le view

Flat view

Front view

COM (3)

COM (3)

COM (3)

COM (3)

NO (4)

NO (4)

NO (4)

NO (4)

NC (5)

NC (5)

NC (5)

NC (5)

P

P

FP

FP

FP

P'HSWK

PP

PP

P

P

FP FP FP FP FP

P

P

P

P

+HLJKWP

*UUXZNXKYNURJ

When sensor is power on , it fl ash10 seconds.

Position the screwdriver as shown to 
remove the masking lens.

To adjust the sensing fi eld , use 
the masking lens. To tailor the 
sensing fi eld, cut the segments.

Use the guide pins to insert the 
masking lens on the front cover.

IS

*UUXZNXKYNURJ

Sensing fi eld examples:

*UUXZNXKYNURJ

IS

Sensing fi eld

No detection fi eld

Sensing fi eld

No detection 

fi eld

DETECTION FIELD SETTING

When sensor detecting movement, LED light up.

Reviews: