1
MINI FLY
2
Remove the aluminum screws on
each side of MFCA bracket with
screwdriver.
Open the front cover, setting and chec-
king the position of dip-switch and poten-
tiometer (take dip-switch&potentiometer
setting for reference.)
Install the masking lens if needed,
and get related detection fi eld(
take detection fi eld setting for
reference.)
Connecting the cable, and fi x the sen-
sor to MFCA base with 2 black screws
, notice the mounting direction, and
make sure the position of wire connec-
tor is facing outside the door(MFCA).
Step 1.
Step 2.
Step 3.
Step 4.
Step 6.
Step 5.
Dip-switch 1
Dip-switch 2
Dip-switch 3
on
Strong interference mode
Passive output(NC)
Hold time:2s
off
Factory mode
Active output(NO)
Hold time:0.5s
54
Working model setting ( Dip-switch 1)
Factory mode: Suit for normal working environment (factory setting).
Strong interference mode: Suit for complex environment with lots of interference source ( this will increase the response time about 10%.)
Stick the template on the ceiling and cut out the hole.
Clip the sensor on the MFCA with screws. If needed
to change the factory settings, please follow up the
following steps (step1-step6):
Protect the sensor periphery before sawing
Mounting template
Ceiling aperture
Þ[
Þ[
The sensor must be fi rmly fastened in order to avoiad vibrations.
Mounting tips:
When mounting the MINI FLY, make sure you adjusting the angle
before tightening the screws.
Always use the aluminum screws to fasten the internal bracket
and the black screws to fi x the sensor.
After changing the parameter,
close the front cover, installed the
bracket, and tighten two screws on
each side of the bracket after adjust
the angle .
"+" stands for the detection fi eld
towards person. MFCA maximum angle
is +4°.
"-" stands for the detection fi eld
towards doors. MFCA maximum angle
is -4°.
MOUNTING & SETTING
DIP-SWITCH SETTING
Outside the door
MINI FLY
3
The above drawings show the typical sensing fi eld dimensions.
You can move the sensor’s detcion fi eld through change the angle of MFCA bracket ( -4° to +4°) .
Relay confi gurations
Active mode
Passive mode
DETECTION
NO DETECTION
Relay model setting (Dip-switch 2)
Adjustment the sensitivity with potentiometer
LED:
Profi le view
Flat view
Front view
COM (3)
COM (3)
COM (3)
COM (3)
NO (4)
NO (4)
NO (4)
NO (4)
NC (5)
NC (5)
NC (5)
NC (5)
P
P
FP
FP
FP
P'HSWK
PP
PP
P
P
FP FP FP FP FP
P
P
P
P
+HLJKWP
*UUXZNXKYNURJ
When sensor is power on , it fl ash10 seconds.
Position the screwdriver as shown to
remove the masking lens.
To adjust the sensing fi eld , use
the masking lens. To tailor the
sensing fi eld, cut the segments.
Use the guide pins to insert the
masking lens on the front cover.
IS
*UUXZNXKYNURJ
Sensing fi eld examples:
*UUXZNXKYNURJ
IS
Sensing fi eld
No detection fi eld
Sensing fi eld
No detection
fi eld
DETECTION FIELD SETTING
When sensor detecting movement, LED light up.