BEA MAGIC SWITCH MS09 Quick Start Manual Download Page 3

3

75.5746.05 MS09 20210115 

 

Page 3 of 4

4”

24”

MS09

Detection 

Range*

Potentiometer:  Detection Zone*

countclockwise 

=

 decrease (4’’ minimum) 

clockwise 

=

 increase (24’’ maximum)

* Detection range is dependent upon 

object size, object orientation, object 

speed, and environmental conditions.

SENSOR FUNCTIONALITY

TIMED MODE

 – Recommended for automatic door applications.  In Timed Mode, a detection activates the 

relay and the relay holds for a predetermined amount of time (0.5 seconds, not adjustable).

TOGGLE MODE

 – Recommended for switch applications.  In Toggle Mode, a detection activates the relay and a 

second detection deactivates the relay.  The relay will hold indefinitely until a second detection occurs.

For the 900 MHz wireless programming instructions, please reference BEA User’s Guide 75.5937 which 
comes with the 900 MHz wireless receiver (sold separately).

WIRELESS FUNCTIONALITY

SETTINGS & ADJUSTMENTS

TROUBLESHOOTING

Can’t find your answer?  Visit www.beainc.com or 

scan QR code for Frequently Asked Questions!

Sensor does not seem to 

detect

Bad or no power

Check power supply.

Detection range too short

Adjust detection zone potentiometer.

Incorrect wiring

Check wiring.

Sensor stays in detection

Environmental conditions

Remove moving objects from around sensor.

Incorrect wiring

Check wiring (NO and NC).

Wrong output mode

Switch output mode to TIMED.

potentiometer

DIP 2

DIP 1

DIP 1:  Timed/Toggle

on (switch up) = toggle mode 

off (switch down) = timed mode

0.5 sec only; not adjustable

DIP 2:  LED

on (switch up) = LED on when not in detection 

off (switch down) = LED on when in detection

Summary of Contents for MAGIC SWITCH MS09

Page 1: ...etection mode motion bidirectional Output hold time 0 5 30 sec Temperature range 4 131 F 20 55 C Weight 0 34 lbs Material ASA PC IP rating IP65 Certification Electromagnetic compatibility EMC according to 2004 108 EC FCC G9B 210161 IC 4680A 210161 75 5746 05 MS09 20210115 Page 1 of 4 TECHNICAL SPECIFICATIONS DESCRIPTION Visit website for available languages of this document IP65 touchless activati...

Page 2: ...he door control move the 2 wires from the activation circuit to power see Technical Specifications for power information TIPS Industrial Doors Cleanrooms Only trained and qualified personnel are recommended to install and set up the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Always test the proper operation of the installation before leav...

Page 3: ... occurs For the 900 MHz wireless programming instructions please reference BEA User s Guide 75 5937 which comes with the 900 MHz wireless receiver sold separately WIRELESS FUNCTIONALITY SETTINGS ADJUSTMENTS TROUBLESHOOTING Can t find your answer Visit www beainc com or scan QR code for Frequently Asked Questions Sensor does not seem to detect Bad or no power Check power supply Detection range too ...

Page 4: ... exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement BEA Inc the sensor manufacturer cannot be held responsible for incorrect installations or incorrect adjustments of the sensor device the...

Reviews: