75.5785.08 IXIO-ST UL INDUSTRIAL 20161220
Page 3 of 8
3
4
+
+
+
OR
WID
TH
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)
Part of the detection field can be masked to reduce it.
The arrow position determines the width of the detection field.
INFRARED SAFETY FIELD
CLOSER
AWAY
If necessary, adjust the AAIR-curtain
angle (from -7° to 4°, default 0°).
Activate the visible* spots to verify the
position of the AAIR-curtain.
ANGLE
SETUP
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 8 in.
The size of the detection field varies according to the moun-
ting height and the settings of the sensor.
The full door width must be covered.
Mounting
height
Detection
width
6.5 ft
7.2 ft
8.2 ft
9.8 ft
11.5 ft
6.5 ft
7.2 ft
8.2 ft
d max
d max
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
DOOR
SETUP 1 (QUICK)
SETUP 2 (ASSISTED)
OR
2 s
4 s
STEP OUT OF THE INFRARED FIELD!
reference picture
test of full door cycle +
reference picture
max.
3 in**